Emergency Zone 3 Modification as a Local Response-Driven Protection Measure Against System Collapse

被引:17
作者
Nikolaidis, Vassilis C. [1 ]
机构
[1] Democritus Univ Thrace DUTH, Dept Elect & Comp Engn, Xanthi 67100, Greece
关键词
Blackout mitigation; cascaded line outages; distance relaying; system protection scheme; zone; 3; VOLTAGE COLLAPSE; OPERATION; STRATEGIES; RELAYS; POWER;
D O I
10.1109/TPWRD.2016.2552644
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a protection scheme that applies two supervisory zones on each distance relay in the transmission system and timers in order to avoid undesirable Zone 3 operations under voltage-stressed system conditions. The speed at which the apparent impedance trajectory crosses the two supervisory zones is measured by the relay in order to determine the rate of change of the apparent impedance. Zone 3 modifications based on the normalized rate of change of the apparent impedance are applied: 1) Zone 3 operating area is reduced by using circle or straight line blinders when the instability is clearly recognized; 2) Zone 3 is blocked when there is no enough time to identify the cause of the apparent impedance transition; and 3) no measure is applied for a fault or a power swing. Simulations performed in a test power system show the effectiveness of this method in mitigating system blackouts due to cascaded outages.
引用
收藏
页码:2114 / 2122
页数:9
相关论文
共 21 条
[1]  
[Anonymous], 2008, C12 IEEEPSRC WG
[2]  
Bai H., P IEEE POW EN SOC GE, P1
[3]   Dynamic performance assessment: Grazing and related phenomena [J].
Donde, V ;
Hiskens, IA .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1967-1975
[4]   Third zone revisited [J].
Horowitz, SH ;
Phadke, AG .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) :23-29
[5]  
IEEE Power and Energy Society Power System Relaying Committee D4-Working Group, 2009, APPL OV DIST REL
[6]  
IEEE Power System Dynamic Performance Committee Task Force on Blackout Experience Mitigation and Role of New Technologies, 2007, PESTR12 IEEE POW SYS
[7]  
IEEE Power System Stability Sub-Committee, 2015, PESTR19 IEEE POW SYS
[8]   An adaptive scheme to prevent undesirable distance protection operation during voltage instability [J].
Jonsson, M ;
Daalder, JE .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (04) :1174-1180
[9]   Synchrophasor-Assisted Zone 3 Operation [J].
Kundu, Pratim ;
Pradhan, Ashok Kumar .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) :660-667
[10]   Sensitivity analysis to operation margin of zone 3 impedance relays with bus power and shunt susceptance [J].
Li, Shenghu ;
Yorino, Naoto ;
Ding, Ming ;
Zoka, Yoshifumi .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) :102-108