Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study

被引:60
作者
Jokinen, Janne J. [1 ]
Werkkala, Kalervo [1 ]
Vainikka, Tiina [1 ]
Perakyla, Tarja [1 ]
Simpanen, Jarmo [1 ]
Ihlberg, Leo [1 ]
机构
[1] Helsinki Univ Hosp, Dept Cardiothorac Surg, FI-00029 Helsinki, Finland
关键词
Coronary artery bypass grafting; Transit-time flow measurement; Graft patency; Receiver operating characteristic analysis; SURGERY; PATENCY; SURVIVAL; REVISION; FAILURE; TRIAL;
D O I
10.1016/j.ejcts.2010.10.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement (TTFM) is the most widely used method for intra-operative graft quality control in coronary artery bypass surgery. Although it may provide the opportunity for the surgeon to promptly revise the graft before the patient is discharged from the operating room, controlled clinical data on the ultimate usefulness of the TTFM are scarce. Clear cut-off values for when to revise grafts have not been set. Methods: A total of 204 consecutive grafts (left internal mammary artery (n = 46), vein graft (n = 155), and radial artery (n = 3)) underwent TTFM in 75 elective coronary artery bypass grafting (CABG) patients. The following parameters were recorded: mean graft flow (MGF), pulsatility index (PI), and insufficiency ratio (IR). After a mean follow-up of 199 +/- 42 days, coronary angiography was performed for assessment of graft patency. Results: A total of 166 grafts were found to be patent (85%), and 29 (15%) were completely occluded. The median and interquartile range (IQR) of MGF for the occluded grafts at the time of surgery was 38 ml min(-1) (IQR, 25 49 ml min(-1)) and for the patent grafts 45 ml min(-1) (IQR, 31-71 ml min(-1); p = ns]. The corresponding PI values were 3.3 (IQR, 2.8-5.0) and 2.2 (IQR, 1.7-3.2; p = 0.003), and the IR values were 1.6 (IQR, 0.6-6.1) and 0.2 (IQR, 0-2.2; p = 0.03). By receiver operating characteristic (ROC) analysis, the highest sensitivity (72%) and specificity (70%) were associated with a PI value > 3.0. However, 49 out of 70 such grafts (70%) were found to be patent. Furthermore, 10 out of 16 (63%) grafts, that had a combination of low flow (MGF < 15 ml min(-1)) and high PI (> 3.0), were patent at control angiography. Conclusions: TTFM predicts graft failure within the 6 months after CABG. However, specific cut-off recommendations for when to revise a graft cannot be set on the basis of TTFM. The cut-off values suggested in the literature lead to unnecessary graft revisions in the majority of cases, and, on the other hand, many technical defects probably remain unnoticed. Better methods to assess the quality of coronary artery bypass grafts are needed. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.
引用
收藏
页码:918 / 923
页数:6
相关论文
共 25 条
[11]   Intraoperative angiography leads to graft revision in coronary artery bypass surgery [J].
Hol, PK ;
Lingaas, PS ;
Lundblad, R ;
Rein, KA ;
Vatne, K ;
Smith, HJ ;
Nitter-Hauge, S ;
Fosse, E .
ANNALS OF THORACIC SURGERY, 2004, 78 (02) :502-505
[12]  
Hol PK, 2001, HEART SURG FORUM, V4, P254
[13]   Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts [J].
Kieser, Teresa Mary ;
Rose, Sarah ;
Kowalewski, Ryszard ;
Betenkie, Israel .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (02) :155-161
[14]   Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts [J].
Kim, KB ;
Kang, CH ;
Lim, C .
ANNALS OF THORACIC SURGERY, 2005, 80 (02) :594-599
[15]   Validation of a new transit time ultrasound flowmeter in man [J].
Laustsen, J ;
Pedersen, EM ;
Terp, K ;
Steinbruchel, D ;
Kure, HH ;
Paulsen, PK ;
Jorgensen, H ;
Paaske, WP .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (01) :91-96
[16]   Intraoperative Grafts Assessment [J].
Leacche, Marzia ;
Balaguer, Jorge M. ;
Byrne, John G. .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2009, 21 (03) :207-212
[17]   Transit-time flow measurement is essential in coronary artery bypass grafting [J].
Leong, DKH ;
Ashok, V ;
Nishkantha, A ;
Shan, YH ;
Sim, EKW .
ANNALS OF THORACIC SURGERY, 2005, 79 (03) :854-858
[18]   Intraoperative coronary graft assessment [J].
Mack, Michael J. .
CURRENT OPINION IN CARDIOLOGY, 2008, 23 (06) :568-572
[19]   Quantitative angiographic assessment of coronary anastomoses performed without cardiopulmonary bypass [J].
Poirier, NC ;
Carrier, M ;
Lespérance, J ;
Côté, G ;
Pellerin, M ;
Perrault, LP ;
Pelletier, LC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (02) :292-297
[20]   Factors affecting saphenous vein graft patency: Clinical and angiographic study in 1402 symptomatic patients operated on between 1977 and 1999 [J].
Shah, PJ ;
Gordon, I ;
Fuller, J ;
Seevanayagam, S ;
Rosalion, A ;
Tatoulis, J ;
Raman, JS ;
Buxton, BF .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (06) :1972-1977