Fabrication of a polystyrene microfluidic chip coupled to electrospray ionization mass spectrometry for protein analysis

被引:19
作者
Hu, Xianqiao [1 ,2 ,3 ]
Dong, Yuanyuan [2 ]
He, Qiaohong [2 ]
Chen, Hengwu [2 ]
Zhu, Zhiwei [1 ,3 ]
机构
[1] China Natl Rice Res Inst, Hangzhou 310006, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[3] Minist Agr, Lab Qual & Safety Risk Assessment Rice Hangzhou, Hangzhou, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 990卷
关键词
Microfluidic chip; Electrospray ionization-mass spectrometry; Polystyrene; Immobilized enzymatic reactor; Gold film electric contact; Interface; CAPILLARY-ELECTROPHORESIS; EMITTER; SEPARATION; PROTEOMICS; MICROCHIP; DIGESTION; TIP; MS;
D O I
10.1016/j.jchromb.2015.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly integrated polystyrene (PS) microfluidic chip coupled to electrospray ionization mass spectrometry for on-chip protein digestion and online analysis was developed. The immobilized enzymatic microreactor for on-chip protein digestion was integrated onto microchip via the novel method of region-selective UV-modification combined with glutaraldehyde-based immobilization. The micro film electric contact for applying high voltage was prepared on chips by using UV-directed electroless plating technique. A micro-tip was machined at the end of main channel, serving as the interface between microchip and mass spectrometric detector. On-chip digestion and online detection of protein was carried out by coupling the microchip with mass spectrometry (MS). The influences of methanol flow rate in side channel on the stability of spray and intensity of signals were investigated systematically. Also the influence of sample flow rate on the performance of immobilized enzymatic reactor were investigated. Stable spray was obtained at the spray voltage of 2.8-3.0 kV and the methanol flow rate of 500-700 nL min(-1) with the relative standard deviation (RSD) of total ion current (TIC) less than 10%. The influence of sample flow rate on the performance of immobilized enzymatic reactor was also studied. The sequence coverage of protein identification decreased with the increase of flow rate of the sample solution. A sequence coverage of 96% was obtained with immobilized enzymatic reactor at the sample flow rate of 100 nL min(-1) with the reaction time of 8.4 min. It could detect cytochrome c as low as 10 mu g mL(-1) with the developed system. No obvious decrease in protein digestion efficiency was observed after the chip continuously performed for 4 h and stored for 15 d. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [31] On-chip electromembrane extraction for monitoring drug metabolism in real time by electrospray ionization mass spectrometry
    Petersen, Nickolaj Jacob
    Pedersen, Jacob Sonderby
    Poulsen, Nicklas Norgard
    Jensen, Henrik
    Skonberg, Christian
    Hansen, Steen Honore
    Pedersen-Bjergaard, Stig
    ANALYST, 2012, 137 (14) : 3321 - 3327
  • [32] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486
  • [33] Analysis of flavonoids in honey by HPLC coupled with coulometric electrode array detection and electrospray ionization mass spectrometry
    Petrus, Karoline
    Schwartz, Heidi
    Sontag, Gerhard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (08) : 2555 - 2563
  • [34] An aptamer-based trypsin reactor for on-line protein digestion with electrospray ionization tandem mass spectrometry
    Xiao, Peng
    Lv, Xuefei
    Wang, Shanshan
    Iqbal, Javed
    Qing, Hong
    Li, Qin
    Deng, Yulin
    ANALYTICAL BIOCHEMISTRY, 2013, 441 (02) : 123 - 132
  • [35] Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Sonomura, Kazuhiro
    Kudoh, Shinobu
    Sato, Taka-Aki
    Matsuda, Fumihiko
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2033 - 2037
  • [36] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [37] Design, modeling, fabrication, and evaluation of the air amplifier for improved detection of biomolecules by electrospray ionization mass spectrometry
    Robichaud, Guillaume
    Dixon, R. Brent
    Potturi, Amarnatha S.
    Cassidy, Dan
    Edwards, Jack R.
    Sohn, Alex
    Dow, Thomas A.
    Muddiman, David C.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2011, 300 (2-3) : 99 - 107
  • [38] On-line Identification of chiral ofloxacin in milk with an extraction/ionization device coupled to Electrospray Mass Spectrometry
    Wang, Jiang
    Jiang, Xiao-Xiao
    Zhao, Wei
    Hu, Jun
    Guan, Qi-Yuan
    Xu, Jing-Juan
    Chen, Hong-Yuan
    TALANTA, 2017, 171 : 190 - 196
  • [39] Comparison of Electrospray Ionization and Atmospheric Chemical Ionization Coupled with the Liquid Chromatography-Tandem Mass Spectrometry for the Analysis of Cholesteryl Esters
    Lee, Hae-Rim
    Kochhar, Sunil
    Shim, Soon-Mi
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 2015
  • [40] A Versatile Microfluidic Chip for Millisecond Time-Scale Kinetic Studies by Electrospray Mass Spectrometry
    Rob, Tamanna
    Wilson, Derek J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (01) : 124 - 130