Fabrication of a polystyrene microfluidic chip coupled to electrospray ionization mass spectrometry for protein analysis

被引:19
作者
Hu, Xianqiao [1 ,2 ,3 ]
Dong, Yuanyuan [2 ]
He, Qiaohong [2 ]
Chen, Hengwu [2 ]
Zhu, Zhiwei [1 ,3 ]
机构
[1] China Natl Rice Res Inst, Hangzhou 310006, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
[3] Minist Agr, Lab Qual & Safety Risk Assessment Rice Hangzhou, Hangzhou, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 990卷
关键词
Microfluidic chip; Electrospray ionization-mass spectrometry; Polystyrene; Immobilized enzymatic reactor; Gold film electric contact; Interface; CAPILLARY-ELECTROPHORESIS; EMITTER; SEPARATION; PROTEOMICS; MICROCHIP; DIGESTION; TIP; MS;
D O I
10.1016/j.jchromb.2015.03.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly integrated polystyrene (PS) microfluidic chip coupled to electrospray ionization mass spectrometry for on-chip protein digestion and online analysis was developed. The immobilized enzymatic microreactor for on-chip protein digestion was integrated onto microchip via the novel method of region-selective UV-modification combined with glutaraldehyde-based immobilization. The micro film electric contact for applying high voltage was prepared on chips by using UV-directed electroless plating technique. A micro-tip was machined at the end of main channel, serving as the interface between microchip and mass spectrometric detector. On-chip digestion and online detection of protein was carried out by coupling the microchip with mass spectrometry (MS). The influences of methanol flow rate in side channel on the stability of spray and intensity of signals were investigated systematically. Also the influence of sample flow rate on the performance of immobilized enzymatic reactor were investigated. Stable spray was obtained at the spray voltage of 2.8-3.0 kV and the methanol flow rate of 500-700 nL min(-1) with the relative standard deviation (RSD) of total ion current (TIC) less than 10%. The influence of sample flow rate on the performance of immobilized enzymatic reactor was also studied. The sequence coverage of protein identification decreased with the increase of flow rate of the sample solution. A sequence coverage of 96% was obtained with immobilized enzymatic reactor at the sample flow rate of 100 nL min(-1) with the reaction time of 8.4 min. It could detect cytochrome c as low as 10 mu g mL(-1) with the developed system. No obvious decrease in protein digestion efficiency was observed after the chip continuously performed for 4 h and stored for 15 d. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [21] Effects of experimental parameters on the signal intensity of capillary electrophoresis electrospray ionization mass spectrometry in protein analysis
    Liang, Z
    Yang, Q
    Zhang, WB
    Zhang, LH
    Zhang, YK
    CHROMATOGRAPHIA, 2003, 57 (9-10) : 617 - 621
  • [22] Technology development trend of electrospray ionization mass spectrometry for single-cell proteomics
    Wu, Yuanyuan
    Zhang, Wenmei
    Zhao, Yaoyao
    Wang, Xiayan
    Guo, Guangsheng
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 159
  • [23] Generating Supercharged Protein Ions for Breath Analysis by Extractive Electrospray Ionization Mass Spectrometry
    Ke, Mufang
    Zhang, Hua
    Ding, Jianhua
    Xiong, Xingchuang
    Li, Fenglei
    Chingin, Konstantin
    Kou, Wei
    Liu, Aiying
    Zhu, Tenggao
    Fang, Xiang
    Chen, Huanwen
    ANALYTICAL CHEMISTRY, 2019, 91 (05) : 3215 - 3220
  • [24] On-line capillary electrophoresis-electrospray ionization mass spectrometry analysis of urinary porphyrins
    Li, Jinhua
    Chan, Wan
    Cai, Zongwei
    ELECTROPHORESIS, 2009, 30 (10) : 1790 - 1797
  • [25] Analysis of heparin oligosaccharides by capillary electrophoresis-negative-ion electrospray ionization mass spectrometry
    Lin, Lei
    Liu, Xinyue
    Zhang, Fuming
    Chi, Lianli
    Amster, I. Jonathan
    Leach, Franklyn E., III
    Xia, Qiangwei
    Linhardt, Robert J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (02) : 411 - 420
  • [26] Integrated microfluidic chip coupled to mass spectrometry: A minireview of chip pretreatment methods and applications
    Chen, Jing
    Tang, Minmin
    Xu, Danke
    JOURNAL OF CHROMATOGRAPHY OPEN, 2021, 1
  • [27] Coupling Microchip Electrospray Ionization Devices with High Pressure Mass Spectrometry
    Gilliland, William M., Jr.
    Mellors, J. Scott
    Ramsey, J. Michael
    ANALYTICAL CHEMISTRY, 2017, 89 (24) : 13320 - 13325
  • [28] Analysis of the glucosinolate pattern of Arabidopsis thaliana seeds by capillary zone electrophoresis coupled to electrospray ionization-mass spectrometry
    Bringmann, G
    Kajahn, I
    Neusüss, C
    Pelzing, M
    Laug, S
    Unger, M
    Holzgrabe, U
    ELECTROPHORESIS, 2005, 26 (7-8) : 1513 - 1522
  • [29] Fully polymeric integrated microreactor/electrospray ionization chip for on-chip digestion and mass spectrometric analysis
    Nissila, Teemu
    Sainiemi, Lauri
    Franssila, Sami
    Ketola, Raimo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 143 (01) : 414 - 420
  • [30] On-chip electromembrane extraction for monitoring drug metabolism in real time by electrospray ionization mass spectrometry
    Petersen, Nickolaj Jacob
    Pedersen, Jacob Sonderby
    Poulsen, Nicklas Norgard
    Jensen, Henrik
    Skonberg, Christian
    Hansen, Steen Honore
    Pedersen-Bjergaard, Stig
    ANALYST, 2012, 137 (14) : 3321 - 3327