Anodic stripping voltammetry of inorganic species of As3+ and As5+ at gold-modified boron doped diamond electrodes
被引:69
作者:
Yamada, Daisuke
论文数: 0引用数: 0
h-index: 0
机构:
Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, JapanKeio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
Yamada, Daisuke
[1
]
Ivandini, Tribidasari A.
论文数: 0引用数: 0
h-index: 0
机构:
Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
Univ Indonesia, Fac Math & Sci, Dept Chem, Jakarta 16424, IndonesiaKeio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
Ivandini, Tribidasari A.
[1
,2
]
Komatsu, Motoharu
论文数: 0引用数: 0
h-index: 0
机构:
Tohoku Elect Power Co Inc, Aoba Ku, Sendai, Miyagi 9810952, JapanKeio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
total inorganic arsenic;
differentiation method;
stripping voltammetry;
gold;
diamond electrodes;
D O I:
10.1016/j.jelechem.2007.12.004
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Electrochemical detection of mixture solutions of As(3+) and As(5+) has been investigated by stripping voltammetry at gold-modified diamond electrodes. The method was performed based on stripping oxidation of As(0) deposited at the electrode surface. Whereas As(3+) can be deposited by simple electrochemical reduction of As(3+) to As(0) at -0.4 V (vs. Ag/AgCl), much higher potential is required to overcome the activation energy of As(5+) reduction. However, in such a high potential, hydrogen evolution also occurs. Consequently, one more step should be added to release the hydrogen gas adsorbed at the electrode surface during the reduction step. During the deposition of As(5+), AS(3+) species was also simultaneously deposited. Therefore, to differentiate AS(3+) and As(5+) quantification in a mixture solution, both stripping voltammetry methods should be performed and calculated mathematically. Comparison of stripping voltammograms of both methods for As(3+) solution in the absence of As(5+) demonstrated similar peak shapes and current intensities, confirming that error calculation of As(5+) concentration in the mixture solution with As(3+) can be avoided. Good linear responses were observed for each standard solution of As(3+) and As(5+). Linear calibration curve could also be achieved for a series concentrations of 100-1000 ppb AS(5+) in a mixture solution with 100 ppb As(3+) (r(2) = 0.99) and for a series concentrations of 5-30 ppb As(3+) in a mixture solution with 100 ppb As(5+). Detection limits of 5 and 100 ppb can be achieved for As(3+) and As(5+) in a mixture solution, respectively. The reproducibility was shown for stripping voltammetry of As(3+) and As(5+) with an RSD (n = 8) of 7.5% and 8.4%,, respectively. Good stability of gold-modified diamond electrodes before and after arsenic detection was also evaluated by SEM image. Application of the method for real sample analysis was performed for arsenic detection in Yokohama tap water. (C) 2008 Elsevier B.V. All rights reserved.