Variation of bispectral index monitoring in paediatric patients undergoing propofol-remifentanil anaesthesia

被引:11
|
作者
Liu, J. S. [3 ]
Zhang, J. M. [2 ]
Yue, Y. [1 ]
机构
[1] Capital Med Univ, Beijing Chaoyang Hosp, Dept Anesthesiol, Beijing 100020, Peoples R China
[2] Bejing Childrens Hosp, Dept Anesthesiol, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Tongren Hosp, Dept Anesthesiol, Beijing, Peoples R China
关键词
child; child preschool; bispectral index; propofol; remifentanil; anaesthesia intravenous;
D O I
10.1017/S0265021508004559
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: The technology of bispectral index monitoring is based on an algorithm developed from adults. This study was conducted to investigate the difference in bispectral index monitoring between paediatric and adult patients under intravenous anaesthesia. Methods: In all, 68 patients undergoing elective surgery were divided into three groups as follows: Group A (younger children, n = 20, 3 yr <= yr <= 5 yr), Group B (older children, n = 20, 6 yr <= yr <= 12 yr), Group C (adults, n = 28, 25 yr <= yr <= 50 yr). All patients were induced by plasma target-controlled infusion of propofol till loss of consciousness (loss of response to verbal commands and eyelash reflex). The plasma concentration (Cp-propofol) and effect-site concentration (Ce-propofol) of propofol and bispectral index values were compared at loss of consciousness and regaining of consciousness. During the operation, remifentanil was infused at a fixed rate of 0.25 mu g kg(-1) min(-1), and the minute average bispectral index values of three groups were also compared at different stable concentrations of propofol (Ce-propofol = Cp-propofol = 2, 3, 4 and 5 mu g mL(-1) respectively). Results: At loss of consciousness and regaining of consciousness, the bispectral index values in Group A (loss of consciousness: 74.7 +/- 6.3, regaining of consciousness: 81.1 +/- 10.5) were significantly higher than those in Group C (loss of consciousness: 68.6 +/- 9.4, regaining of consciousness: 74.5 +/- 6.0) (P < 0.01). There was no statistical difference between Cp-propofol in all groups at loss of consciousness and regaining of consciousness. The Ce-propofol at loss of consciousness in Group A (3.57 +/- 0.60 mu g mL(-1)) and B (3.25 +/- 0.44 mu g mL(-1)) were significantly higher than those in Group C (2.15 +/- 0.86 mu g mL(-1)) (P < 0.01). At the same stable concentrations of propofol, the bispectral index values in Group A and B were significantly higher than those in Group C, and the bispectral index values in Group A were also significantly higher than those in Group B (P < 0.01). The Ce-propofol when bispectral index <= 40 in Group A, B, C were approximately at 6, 5 and 3 mu g mL(-1), respectively. Conclusions: At loss of consciousness and regaining of consciousness, the bispectral index values of younger children group are significantly higher than those of adults. At the same stable concentrations of propofol, the bispectral index values are significantly different between children and adults. This study suggests that there is deviation when the adult algorithm of bispectral index monitoring is applied in paediatric patients under intravenous anaesthesia.
引用
收藏
页码:821 / 825
页数:5
相关论文
共 50 条
  • [31] Can the Cerebral State Monitor replace the Bispectral Index in monitoring hypnotic effect during propofol/remifentanil anaesthesia?
    Hoymork, S. C.
    Hval, K.
    Jensen, E. W.
    Raeder, J.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (02) : 210 - 216
  • [32] Variation of bispectral index under TIVA with propofol in a paediatric population
    Tirel, O.
    Wodey, E.
    Harris, R.
    Bansard, J. Y.
    Ecoffey, C.
    Senhadji, L.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) : 82 - 87
  • [33] No Evidence of Memory Processing During Propofol-Remifentanil Target-Controlled Infusion Anesthesia With Bispectral Index Monitoring in Cardiac Surgery
    Bejjani, Gilbert
    Lequeux, Pierre-Yves
    Schmartz, Denis
    Engelman, Edgard
    Barvais, Luc
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (02) : 175 - 181
  • [34] Datex-Ohmeda Entropy Module and Bispectral Index during propofol/remifentanil anaesthesia
    Schmidt, G. N.
    Bischoff, P.
    Hellstern, A.
    Standl, T.
    Teuber, O.
    Esch, J. Schulte Am
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 31 - 32
  • [35] The Narcotrend™ -: a new EEG monitor designed measure the depth of anaesthesia -: A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia
    Kreuer, S
    Biedler, A
    Larsen, R
    Schoth, S
    Altmann, S
    Wilhelm, W
    ANAESTHESIST, 2001, 50 (12): : 921 - 925
  • [36] Impact of bispectral index monitoring on propofol administration in patients undergoing cardiopulmonary bypass
    Chiu, C. L.
    Ong, G.
    Majid, A. A.
    ANAESTHESIA AND INTENSIVE CARE, 2007, 35 (03) : 342 - 347
  • [37] Pharmacokinetics and pharmacodynamics of propofol during propofol-alfentanil and propofol-remifentanil total intravenous anaesthesia monitored by spectral frequency index
    Bienert, Agnieszka
    Zaba, Zbigniew
    Grzeskowiak, Edmund
    Kusza, Krzysztof
    Grabowski, Tomasz
    MEDICAL SCIENCE MONITOR, 2009, 15 (10): : PI47 - PI53
  • [38] Bispectral index monitoring during electroconvulsive therapy under propofol anaesthesia
    Gunawardane, PO
    Murphy, PA
    Sleigh, JW
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (02) : 184 - 187
  • [39] EVALUATION OF A PROPOFOL-REMIFENTANIL RESPONSE SURFACE MODEL IN PATIENTS UNDERGOING ULTRASONIC ENDOSCOPY
    Evans, T.
    LaPierre, C.
    Gambus, P.
    Johnson, K. B.
    Egan, T.
    Westenskow, D.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [40] Bispectral index (BIS) monitoring during propofol-induced sedation and anaesthesia
    Singh, H
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (01) : 31 - 36