Effect of bonded length on the load response and failure mode of pull-out tests of GFRP bars embedded in concrete

被引:14
|
作者
Zhao, Xudong [1 ]
Rahman, Mohammod Minhajur [1 ]
D'Antino, Tommaso [2 ]
Focacci, Francesco [3 ]
Carloni, Christian [1 ]
机构
[1] Case Western Reserve Univ, Dept Civil & Environm Engn, Cleveland, OH 44106 USA
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Milan, Italy
[3] eCampus Univ, Novedrate, Italy
关键词
Glass fiber reinforced polymer (GFRP); Bonded length; Pull-out tests; REINFORCED POLYMER BARS; BEHAVIOR; GLASS; STRENGTH; CRACKING; PERFORMANCE; STRESS; BEAMS;
D O I
10.1016/j.conbuildmat.2022.128425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the experimental results of pull-out tests of glass fiber-reinforced polymer (GFRP) bars embedded in concrete are presented and discussed. The experimental work is designed to investigate the effect of the bonded length on the bond behavior of the bars. Five bonded lengths are considered. The first bonded length is equal to 5 times the bar diameter (db), which is the bonded length recommended in ASTM D7913. The other four bonded lengths are equal to 10db, 20db, 30db, and 40db. Loaded-end displacement is obtained from the measurements of three linear variable displacement transformers (LVDTs). Pull-out tests are performed in displacement control. For some specimens, the free-end displacement is measured by two additional LVDTs. The load responses in terms of applied load versus machine stroke, loaded-end slip, and free-end slip are plotted and compared for the different bonded lengths. The average shear stress is plotted versus the bonded length. Finally, the maximum axial stress in pull-out tests is plotted versus the bonded length and compared with the prediction of ACI 440.1R-15.
引用
收藏
页数:18
相关论文
共 43 条