The effect of different enamel surface treatments on the microleakage of fissure sealants

被引:32
作者
Baygin, Ozgul [1 ]
Korkmaz, Fatih Mehmet [2 ]
Tuzuner, Tamer [1 ]
Tanriver, Mehmet [1 ]
机构
[1] Karadeniz Tech Univ, Fac Dent, Dept Pediat Dent, Trabzon, Turkey
[2] Karadeniz Tech Univ, Fac Dent, Dept Prosthodont, Trabzon, Turkey
关键词
Er; Cr:YSGG laser; CoJet Prep; Fissurotomy bur; Etching; Fissure sealant; Microleakage; ER-YAG-LASER; SHEAR BOND STRENGTH; AIR-ABRASION; CAVITY PREPARATION; PREPARED DENTIN; SEM EVALUATION; PRIMARY TEETH; ACID; PIT; PRETREATMENT;
D O I
10.1007/s10103-011-0918-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to evaluate the effects of different techniques of surface treatment on the microleakage of a fissure sealant in molar teeth. A total of 50 freshly extracted noncarious human third molars were randomly assigned to one of five groups. Occlusal fissures were treated with one of the following: acid etching with 35% orthophosphoric acid (group 1); fissurotomy with a Fissurotomy Micro NTF metal bur (group 2); laser etching with an Er,Cr:YSGG laser at 2 W and 20 Hz (group 3); laser etching with an Er,Cr:YSGG laser at 2 W and 40 Hz (group 4); and air abrasion for 20 s with 30-A mu m Al2O3 particles via a CoJet Prep device (group 5). After surface pretreatment, a resin-based sealant was applied to the fissures. The sample teeth were subjected to thermocycling and stored in distilled water at 37A degrees C for 1 month. Following immersion in 0.5% basic fuchsin solution for 24 h, three buccolingual slices of each sample tooth were scored under a stereomicroscope, and the morphological appearance of the area between the enamel surface and fissure sealant was examined under a scanning electron microscope. The Kruskal-Wallis test and one-way ANOVA revealed significant differences in marginal leakage, as follows: group 1 showed significantly lower scores than groups 2 and 5, the scores of groups 1, 3 and 4 were not significantly different, and group 2 showed significantly higher scores than groups 3 and 4. Laser irradiation, the metal bur, and the CoJet Prep device did not eliminate the need for acid etching of the enamel prior to placement of a fissure sealant. Laser etching at 2 W (20 Hz or 40 Hz) may be an alternative to conventional acid-etching.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 44 条
[1]  
ARIO PD, 1994, J DENT RES, V73, P132
[2]   Er:YAG laser cavity preparation and composite resin bonding with a single-component adhesive system:: Relationship between shear bond strength and microleakage [J].
Bertrand, Marie-France ;
Semez, Gianfranco ;
Leforestier, Eric ;
Muller-Bolla, Michele ;
Nammour, Samir ;
Rocca, Jean-Paul .
LASERS IN SURGERY AND MEDICINE, 2006, 38 (06) :615-623
[3]  
Bevilacqua L, 2007, Eur J Paediatr Dent, V8, P25
[4]  
Borsatto Maria Cristina, 2004, J Dent Child (Chic), V71, P143
[5]  
Cehreli SB, 2006, J ADHES DENT, V8, P381
[6]  
Coluzzi Donald J, 2004, Dent Clin North Am, V48, P751, DOI 10.1016/j.cden.2004.05.003
[7]  
Corona SAM, 2001, OPER DENT, V26, P491
[8]   Microleakage of class v glass ionomer restorations after conventional and Er:YAG laser preparation [J].
Delme, Katleen Ilse Maria ;
Deman, Peter Jean ;
Nammour, Samir ;
Gentil De Moor, Roeland Jozef .
PHOTOMEDICINE AND LASER SURGERY, 2006, 24 (06) :715-722
[9]  
do Rego M A, 1999, J Clin Pediatr Dent, V24, P63
[10]   Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel [J].
Dunn, WJ ;
Davis, JT ;
Bush, AC .
DENTAL MATERIALS, 2005, 21 (07) :616-624