PVC membrane electrode for the potentiometric determination of Ipratropium bromide using batch and flow injection techniques

被引:13
|
作者
Hassouna, M. E. M. [1 ]
Elsuccary, S. A. A. [1 ]
机构
[1] Beni Suef Univ, Fac Sci, Bani Suwayf, Egypt
关键词
Ipratropium bromide; PVC membrane electrodes; potentiometric determination; flow injection analysis;
D O I
10.1016/j.talanta.2008.01.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ipratropium (IP+) ion-selective electrode (ISE) has been constructed from poly(vinyl chloride) matrix membrane containing Ipratropium-tetraphenylborate (IP-TPB) as the electroactive component using 2-nitrophenyloctylether as plasticizer. The electrode exhibits near Nernstian response to Ipratropium bromide (IPBr) over the concentration range 10(-5) to 10(-2) mol L-1 and detection limit 5.1 x 10(-6) mol L-1. The electrode offers significant advantages including long lifetime (>2 months), excellent stability and reproducibility, fast response time (<10 s), wide pH working range (pH 2-9), high thermal stability (isothermal coefficient 0.37 mV/degrees C) and superior selectivity for IPBr over a large number of inorganic and organic substances. The electrode was successfully used as indicator electrode in the potentiometric titration of IPBr versus sodium tetraphenylborate (NaTPB) and in the determination of IPBr in Atrovent (R) vials and spiked urine samples applying batch and flow injection techniques, with satisfactory results. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1175 / 1183
页数:9
相关论文
共 50 条
  • [1] Novel PVC-membrane electrode for flow injection potentiometric determination of Biperiden in pharmaceutical preparations
    Khaled, Elmorsy
    EI-Sabbagh, Inas A.
    El-Kholy, N. G.
    Ghahni, E. Y. Abdel
    TALANTA, 2011, 87 : 40 - 45
  • [2] Polymeric Membrane Sensors for Batch and Flow Injection Potentiometric Determination of Procainamide
    Alrabiah, Haitham
    Homoda, Atef M. A.
    Radowan, Abdellatef A.
    Ezzeldin, Essam
    Mostafa, Gamal A. E.
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4198 - 4208
  • [3] Potentiometric Determination of Sibutramine Using Batch and Flow Injection Analysis
    El Gohary, Nesrine A.
    El Nashar, Rasha M.
    Aboul-Enien, Hassan Y.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 241 - 257
  • [4] Potentiometric flow injection determination of serum bromide in patients with epilepsy
    Katsu, T
    Mori, Y
    Matsuka, N
    Gomita, Y
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (12) : 1829 - 1832
  • [5] Carbon paste and PVC electrodes for the flow injection potentiometric determination of dextromethorphan
    Khaled, Elmorsy
    Hassan, H. N. A.
    Mohamed, Gehad G.
    Seleim, A. A.
    TALANTA, 2010, 81 (1-2) : 510 - 515
  • [6] Potentiometric Determination of Imatinib under Batch and Flow Injection Analysis Conditions
    Karim, Shereen E. Abdel
    El-Nashar, Rasha M.
    Abadi, Ashraf H.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (10): : 9668 - 9681
  • [7] Flow injection determination of ketotifen fumarate using PVC membrane selective electrodes
    Khater, M. M.
    Issa, Y. M.
    Mohammed, Sabrein H.
    BIOELECTROCHEMISTRY, 2009, 77 (01) : 53 - 59
  • [8] Flow injection determination of bromide ion in a developer using bromide ion-selective electrode detector
    Masadome, T
    Asano, Y
    Nakamura, T
    TALANTA, 1999, 50 (03) : 595 - 600
  • [9] Potentiometric flow-injection determination of cysteine in the presence of cystine using a tubular electrode with Ag(I)-based membrane as detector
    Komljenovic, J
    Radic, N
    ANALUSIS, 1996, 24 (03) : 63 - 65
  • [10] PVC membrane electrodes for potentiometric determination of tripelennamine
    ElNemma, EM
    MIKROCHIMICA ACTA, 1997, 127 (3-4) : 259 - 263