Reproducibility of MRI-Determined Proton Density Fat Fraction Across Two Different MR Scanner Platforms

被引:132
作者
Kang, Geraldine H. [1 ]
Cruite, Irene [1 ]
Shiehmorteza, Masoud [1 ]
Wolfson, Tanya [2 ]
Gamst, Anthony C. [2 ]
Hamilton, Gavin [1 ]
Bydder, Mark [1 ]
Middleton, Michael S. [1 ]
Sirlin, Claude B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiol, Liver Imaging Grp, Med Ctr,MR3T Lab, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Computat & Appl Stat Lab, San Diego Supercomp Ctr, La Jolla, CA 92093 USA
基金
美国国家卫生研究院;
关键词
MR imaging-based fat quantification; hepatic steatosis; proton density fat fraction; PDFF; MR spectroscopy; MRS; chemical shift imaging; CSI; MAGNETIC-RESONANCE-SPECTROSCOPY; GRADIENT-ECHO; LIVER-DISEASE; QUANTIFICATION; STEATOSIS; QUANTITATION; ACCURACY; BIOPSY;
D O I
10.1002/jmri.22701
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate magnetic resonance imaging (MRI)-determined proton density fat fraction (PDFF) reproducibility across two MR scanner platforms and, using MR spectroscopy (MRS)-determined PDFF as reference standard, to confirm MRI-determined PDFF estimation accuracy. Materials and Methods: This prospective, cross-sectional, crossover, observational pilot study was approved by an Institutional Review Board. Twenty-one subjects gave written informed consent and underwent liver MRI and MRS at both 1.5T (Siemens Symphony scanner) and 3T (GE Signa Excite HD scanner). MRI-determined PDFF was estimated using an axial 2D spoiled gradient-recalled echo sequence with low flip-angle to minimize T1 bias and six echo-times to permit correction of T2* and fat-water signal interference effects. MRS-determined PDFF was estimated using a stimulated-echo acquisition mode sequence with long repetition time to minimize T1 bias and five echo times to permit T2 correction. Interscanner reproducibility of MRI determined PDFF was assessed by correlation analysis; accuracy was assessed separately at each field strength by linear regression analysis using MRS-determined PDFF as reference standard. Results: 1.5T and 3T MRI-determined PDFF estimates were highly correlated (r = 0.992). MRI-determined PDFF estimates were accurate at both 1.5T (regression slope/intercept = 0.958/-0.48) and 3T (slope/intercept = 1.020/0.925) against the MRS-determined PDFF reference. Conclusion: MRI-determined PDFF estimation is reproducible and, using MRS-determined PDFF as reference standard, accurate across two MR scanner platforms at 1.5T and 3T.
引用
收藏
页码:928 / 934
页数:7
相关论文
共 31 条
[1]   Comparison of fat quantification methods: A phantom study at 3.0T [J].
Bernard, Clare P. ;
Liney, Gary P. ;
Manton, David J. ;
Turnbull, Lindsay W. ;
Langton, Christian M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) :192-197
[2]  
Brunt Elizabeth M, 2002, Clin Liver Dis, V6, P399, DOI 10.1016/S1089-3261(02)00002-8
[3]  
Brunt EM, 1999, AM J GASTROENTEROL, V94, P2467, DOI 10.1111/j.1572-0241.1999.01377.x
[4]   Relaxation effects in the quantification of fat using gradient echo imaging [J].
Bydder, Mark ;
Yokoo, Takeshi ;
Hamilton, Gavin ;
Middleton, Michael S. ;
Chavez, Alyssa D. ;
Schwimmer, Jeffrey B. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (03) :347-359
[5]   Nonalcoholic fatty liver disease: From steatosis to cirrhosis [J].
Farrell, GC ;
Larter, CZ .
HEPATOLOGY, 2006, 43 (02) :S99-S112
[6]   Multiecho MR Imaging and Proton MR Spectroscopy for Liver Fat Quantification [J].
Guiu, Boris ;
Loffroy, Romaric ;
Cercueil, Jean-Pierre ;
Krause, Denis .
RADIOLOGY, 2008, 249 (03) :1081-1081
[7]   Quantification of Liver Fat Content: Comparison of Triple-Echo Chemical Shift Gradient-Echo Imaging and in Vivo Proton MR Spectroscopy [J].
Guiu, Boris ;
Petit, Jean-Michel ;
Loffroy, Romaric ;
Salem, Douraied Ben ;
Aho, Serge ;
Masson, David ;
Hillon, Patrick ;
Krause, Denis ;
Cercueil, Jean-Pierre .
RADIOLOGY, 2009, 250 (01) :95-102
[8]  
Hamilton G, 2010, NMR BIOMED
[9]   Effect of PRESS and STEAM Sequences on Magnetic Resonance Spectroscopic Liver Fat Quantification [J].
Hamilton, Gavin ;
Middleton, Michael S. ;
Bydder, Mark ;
Yokoo, Takeshi ;
Schwimmer, Jeffrey B. ;
Kono, Yuko ;
Patton, Heather M. ;
Lavine, Joel E. ;
Sirlin, Claude B. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (01) :145-152
[10]   Hepatic fat fraction: MR imaging for quantitative measurement and display - Early experience [J].
Hussain, HK ;
Chenevert, TL ;
Londy, FJ ;
Gulani, V ;
Swanson, SD ;
McKenna, BJ ;
Appelman, HD ;
Adusumilli, S ;
Greenson, JK ;
Conjeevaram, HS .
RADIOLOGY, 2005, 237 (03) :1048-1055