Trends in the Use of Percutaneous Ventricular Assist Devices Analysis of National Inpatient Sample Data, 2007 Through 2012

被引:111
作者
Khera, Rohan [1 ]
Cram, Peter [2 ,3 ]
Lu, Xin [4 ]
Vyas, Ankur [5 ]
Gerke, Alicia [6 ]
Rosenthal, Gary E. [4 ,7 ]
Horwitz, Phillip A. [5 ]
Girotra, Saket [4 ,5 ]
机构
[1] Univ Iowa, Dept Internal Med, Carver Coll Med, Iowa City, IA 52242 USA
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
[3] Mt Sinai Hosp, Univ Hlth Network, Div Gen Internal Med, Toronto, ON M5G 1X5, Canada
[4] Univ Iowa, Carver Coll Med, Inst Clin & Translat Sci, Iowa City, IA USA
[5] Univ Iowa, Dept Internal Med, Carver Coll Med, Div Cardiovasc Med, Iowa City, IA 52242 USA
[6] Univ Iowa, Dept Internal Med, Carver Coll Med, Div Pulm Crit Care & Occupat Med, Iowa City, IA 52242 USA
[7] Univ Iowa, Dept Internal Med, Carver Coll Med, Div Gen Internal Med, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
INTRAAORTIC BALLOON SUPPORT; RANDOMIZED CLINICAL-TRIAL; CORONARY INTERVENTION; CARDIOGENIC-SHOCK; MYOCARDIAL-INFARCTION; CIRCULATORY SUPPORT; IMPELLA; 2.5; PUMP; COUNTERPULSATION;
D O I
10.1001/jamainternmed.2014.7856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IMPORTANCE Percutaneous ventricular assist devices (PVADs) provide robust hemodynamic support compared with intra-aortic balloon pumps (IABPs), but clinical use patterns are unknown. OBJECTIVE To examine contemporary patterns in PVAD use in the United States and compare them with use of IABPs. DESIGN, SETTING, AND PARTICIPANTS Retrospective study of adults older than 18 years who received a PVAD or IABP while hospitalized in the United States (2007-2012). MAIN OUTCOMES AND MEASURES Temporal trends in utilization, patient and hospital characteristics, in-hospital mortality, and cost of PVAD use compared with IABP. RESULTS During 2007 through 2012, utilization of PVADs increased 30-fold (4.6 per million discharges in 2007 to 138 per million discharges in 2012; P for trend < .001) while utilization of IABPs decreased from 1738 per million discharges in 2008 to 1608 per million discharges in 2012 (P for trend = .02). In 2007, an estimated 72 hospitals used PVADs, increasing to 477 in 2011 (P for trend < .001). The number of hospitals with an annual volume of 10 or more PVAD procedures per year increased from 0 in 2007 to 102 in 2011 (21.4% of PVAD-using hospitals; P for trend < .001). Among PVAD recipients, 67.3% had a diagnosis of cardiogenic shock or acute myocardial infarction (AMI). There was a temporal increase in the use of PVADs in older patients and patients with AMI, hypertension, diabetes mellitus, and chronic kidney disease (P for trend < .001 for all). Overall, mortality in PVAD recipients was 28.8%, and mean (SE) hospitalization cost was $85 580 ($4165); both were significantly higher in PVAD recipients with cardiogenic shock (mortality, 47.5%; mean [SE] cost, $113 695 [$6260]; P < .001 for both). The PVAD recipients were less likely than IABP recipients to have cardiogenic shock (34.3% vs 41.2%; P = .001), AMI (48.0% vs 68.6%; P < .001), and undergo coronary artery bypass graft surgery (6.2% vs 43.2%; P < .001), but more likely to undergo percutaneous coronary intervention (70.9% vs 40.4%; P < .001). In propensity-matched analysis, PVADs were associated with higher mortality compared with IABP (odds ratio, 1.23 [95% CI, 1.06-1.43]; P = .007). CONCLUSIONS AND RELEVANCE There has been a substantial increase in the use of PVADs in recent years with an accompanying decrease in the use of IABPs. Given the high mortality, associated cost, and uncertain evidence for a clear benefit, randomized clinical trials are needed to determine whether use of PVADs leads to improved patient outcomes.
引用
收藏
页码:941 / 950
页数:10
相关论文
共 31 条
[21]  
O'Gara PT, 2013, CIRCULATION, V127, P529, DOI [10.1161/CIR.0b013e3182742cf6, 10.1161/CIR.0b013e3182742c84, 10.1016/j.jacc.2012.11.019]
[22]   A Prospective, Randomized Clinical Trial of Hemodynamic Support With Impella 2.5 Versus Intra-Aortic Balloon Pump in Patients Undergoing High-Risk Percutaneous Coronary Intervention The PROTECT II Study [J].
O'Neill, William W. ;
Kleiman, Neal S. ;
Moses, Jeffrey ;
Henriques, Jose P. S. ;
Dixon, Simon ;
Massaro, Joseph ;
Palacios, Igor ;
Maini, Brijeshwar ;
Mulukutla, Suresh ;
Dzavik, Vladimir ;
Popma, Jeffrey ;
Douglas, Pamela S. ;
Ohman, Magnus .
CIRCULATION, 2012, 126 (14) :1717-+
[23]   Long-Term Mortality Data From the Balloon Pump-Assisted Coronary Intervention Study (BCIS-1) A Randomized, Controlled Trial of Elective Balloon Counterpulsation During High-Risk Percutaneous Coronary Intervention [J].
Perera, Divaka ;
Stables, Rod ;
Clayton, Tim ;
De Silva, Kalpa ;
Lumley, Matthew ;
Clack, Lucy ;
Thomas, Martyn ;
Redwood, Simon .
CIRCULATION, 2013, 127 (02) :207-212
[24]   Cardiogenic shock - Current concepts and improving outcomes [J].
Reynolds, Harmony R. ;
Hochman, Judith S. .
CIRCULATION, 2008, 117 (05) :686-697
[25]   A Randomized Clinical Trial to Evaluate the Safety and Efficacy of a Percutaneous Left Ventricular Assist Device Versus Intra-Aortic Balloon Pumping for Treatment of Cardiogenic Shock Caused by Myocardial Infarction [J].
Seyfarth, Melchior ;
Sibbing, Dirk ;
Bauer, Iris ;
Froehlich, Georg ;
Bott-Fluegel, Lorenz ;
Byrne, Robert ;
Dirschinger, Josef ;
Kastrati, Adnan ;
Schoemig, Albert .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (19) :1584-1588
[26]   Serum Biomarkers in Severe Refractory Cardiogenic Shock [J].
Shah, Nishant R. ;
Bieniarz, Mark C. ;
Basra, Sukhdeep S. ;
Paisley, Robert D. ;
Loyalka, Pranav ;
Gregoric, Igor D. ;
Mann, Douglas L. ;
Kar, Biswajit .
JACC-HEART FAILURE, 2013, 1 (03) :200-206
[27]   Supported High-Risk Percutaneous Coronary Intervention With the Impella 2.5 Device The Europella Registry [J].
Sjauw, Krischan D. ;
Konorza, Thomas ;
Erbel, Raimund ;
Danna, Paolo L. ;
Viecca, Maurizio ;
Minden, Hans-Heinrich ;
Butter, Christian ;
Engstrom, Thomas ;
Hassager, Christian ;
Machado, Francisco P. ;
Pedrazzini, Giovanni ;
Wagner, Daniel R. ;
Schamberger, Rainer ;
Kerber, Sebastian ;
Mathey, Detlef G. ;
Schofer, Joachim ;
Engstrom, Annemarie E. ;
Henriques, Jose P. S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (25) :2430-2434
[28]   Randomized comparison of intra-aortic balloon support with a percutaneous left ventricutar assist device in patients with revascularized acute myocardial infarction complicated by cardiogenic shock [J].
Thiele, H ;
Sick, P ;
Boudriot, E ;
Diederich, KW ;
Hambrecht, R ;
Niebauer, J ;
Schuler, G .
EUROPEAN HEART JOURNAL, 2005, 26 (13) :1276-1283
[29]   Intraaortic Balloon Support for Myocardial Infarction with Cardiogenic Shock [J].
Thiele, Holger ;
Zeymer, Uwe ;
Neumann, Franz-Josef ;
Ferenc, Miroslaw ;
Olbrich, Hans-Georg ;
Hausleiter, Joerg ;
Richardt, Gert ;
Hennersdorf, Marcus ;
Empen, Klaus ;
Fuernau, Georg ;
Desch, Steffen ;
Eitel, Ingo ;
Hambrecht, Rainer ;
Fuhrmann, Joerg ;
Boehm, Michael ;
Ebelt, Henning ;
Schneider, Steffen ;
Schuler, Gerhard ;
Werdan, Karl .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (14) :1287-1296
[30]   Mechanical circulatory support in cardiogenic shock [J].
Werdan, Karl ;
Gielen, Stephan ;
Ebelt, Henning ;
Hochman, Judith S. .
EUROPEAN HEART JOURNAL, 2014, 35 (03) :156-+