Non-invasive estimation of arterial compliance

被引:0
|
作者
Joseph, Jayaraj [1 ]
Venkataraman, Jayashankar [1 ]
Kumar, Jagadeesh, V [1 ]
Suresh, S. [2 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
[2] Mediscan Syst, Madras, Tamil Nadu, India
来源
2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) | 2011年
关键词
arterial compliance; virtual instrument; pulse wave velocity (PWV); PULSE-WAVE VELOCITY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The evaluation of arterial compliance is very important in cardiovascular screening of "at-risk" patients. Existing techniques for local arterial stiffness estimation put a premium on technology and operator expertise. Regional stiffness, measured in terms of the pulse wave velocity, is prone to errors in both path-length and delay estimation. Here, we present a Virtual Instrument (VI) for automated estimation of both local and regional arterial compliance measures. Local arterial compliance is evaluated by utilizing an ultrasound transducer to measure the distension and lumen diameter of the carotid artery. The regional stiffness is estimated from the pulse wave velocity, measured using two magnetic transducers in a dual-channel arrangement. The automated measurement algorithms are thoroughly analyzed, to identify and minimize possible error sources as well as to optimize the design of both the transducer and the virtual instrument. The results of a few human trials are also presented to illustrate the capability of the VI to measure arterial compliance in-vivo.
引用
收藏
页码:480 / 484
页数:5
相关论文
共 50 条
  • [41] Favourable effects of kidney transplantation on vascular condition of patients Potential prognostic significance of non-invasive measurement of arterial stiffness
    Kovacs David Agoston
    Asztalos, Laszlo
    Laczik Renata
    Fedor Roland
    Szabo Laszlo
    Locsey Lajos
    Soltesz, Pal
    ORVOSI HETILAP, 2016, 157 (24) : 956 - 963
  • [42] Non-invasive assessment of ventricular-arterial coupling: correlation between myocardial work and the pulse wave velocity parameters
    Parlavecchio, Antonio
    Caminiti, Rodolfo
    Vetta, Giampaolo
    Magnocavallo, Michele
    Della Rocca, Domenico Giovanni
    Foti, Rosario
    Ajello, Manuela
    Crea, Pasquale
    Dattilo, Giuseppe
    Siviglia, Massimo
    Postorino, Stefano
    Pangallo, Antonio
    Benedetto, Francesco Antonio
    Zito, Concetta
    Carerj, Scipione
    COR ET VASA, 2023, 65 (01) : 51 - 56
  • [43] Instrument for the non-invasive evaluation of human arterial endothelial function via measurement of changes in the transit time of an artificial pulse
    Maltz, JS
    Budinger, TF
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3133 - 3136
  • [44] Validation of a new non-invasive portable tonometer for determining arterial pressure wave and pulse wave velocity: the PulsePen device
    Salvi, P
    Lio, G
    Labat, C
    Ricci, E
    Pannier, B
    Benetos, A
    JOURNAL OF HYPERTENSION, 2004, 22 (12) : 2285 - 2293
  • [45] Standardization of a new non-invasive device for assessment of arterial stiffness in rats: Correlation with age-related arteries' structure
    Fabricio, Mayara F.
    Jordao, Maria T.
    Miotto, Danyelle S.
    Ruiz, Thalles F. R.
    Vicentini, Carlos A.
    Lacchini, Silvia
    Santos, Carlos Ferreira
    Michelini, Lisete C.
    Amaral, Sandra L.
    METHODSX, 2020, 7
  • [46] New closed-form expressions for the estimation of arterial windkessel compliance
    Gnudi, G
    COMPUTERS IN BIOLOGY AND MEDICINE, 1998, 28 (03) : 207 - 223
  • [47] Robust arterial compliance estimation with Katz's fractal dimension of photoplethysmography
    Xing, Xiaoman
    Hong, Jingyuan
    Alastruey, Jordi
    Long, Xi
    Liu, Haipeng
    Dong, Wen-Fei
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [48] ESTIMATION OF ARTERIAL COMPLIANCE IN AORTIC REGURGITATION - 3 METHODS EVALUATED IN PIGS
    SLORDAHL, SA
    PIENE, H
    SOLBAKKEN, JE
    ROSSVOLL, O
    SAMSTAD, SO
    ANGELSEN, BAJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (04) : 293 - 299
  • [49] Combination of Invasive and Non-Invasive Vascular Examinations: Usefulness from the Preemptive Aspect
    Takaya, Tomofumi
    Ishida, Tatsuro
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2015, 22 (10) : 1027 - 1029
  • [50] A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study
    Shin, Hangsik
    PSYCHOPHYSIOLOGY, 2023, 60 (02)