Transient endothelial dysfunction following flow-mediated dilation assessment

被引:15
|
作者
Nerla, Roberto [2 ]
Di Monaco, Antonio [2 ]
Sestito, Alfonso [2 ]
Lamendola, Priscilla [2 ]
Di Stasio, Enrico [3 ]
Romitelli, Federica [3 ]
Lanza, Gaetano Antonio [1 ,2 ]
Crea, Filippo [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Ist Cardiol, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dipartimento Med Cardiovasc, I-00168 Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Biochim & Biochim Clin, I-00168 Rome, Italy
关键词
Flow mediated dilation; Arginine; Endothelial function; CORONARY-ARTERY-DISEASE; NITRIC-OXIDE SYNTHESIS; ASYMMETRIC DIMETHYLARGININE; CARDIOVASCULAR RISK; L-ARGININE; ENDOGENOUS INHIBITOR; BRACHIAL-ARTERY; DIMETHYLAMINOHYDROLASE; VASODILATION; AUGMENTATION;
D O I
10.1007/s00380-010-0087-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow-mediated dilation (FMD) is a widely used tool to investigate endothelial function. However, FMD assessment may cause mechanical damage to the arterial endothelium. In this study we investigated the effect of FMD assessment on endothelial function. We studied 20 healthy subjects (26 +/- 6 years; 12 males). FMD was assessed by measuring brachial artery dilation in response to hyperemia after 5 min of forearm cuff inflation. Subjects were studied on 2 subsequent days. On day 1 they underwent two consecutive FMD measures, with the second test (FMD2) performed 15 min after the first test (FMD1). On day 2, the subjects were randomized to receive either placebo (saline) or intravenous L-arginine (10 g in 20 min). At the end of the infusion, patients underwent two consecutive FMD measures following the same protocol as on day 1. Asymmetric dimethyl-arginine (ADMA) serum levels were assessed on day 2 before FMD1 and FMD2. On day 1, FMD2 was lower than FMD1 in both groups (placebo 6.47 +/- 2.1 vs. 7.86 +/- 1.8%, P < 0.01; arginine 6.13 +/- 2.6 vs. 7.76 +/- 2.7%, P < 0.01). On day 2, a significant reduction of FMD was observed during FMD2 compared to FMD1 in the placebo group (5.82 +/- 1.7 vs. 7.44 +/- 2.2%, P < 0.001), but not in the arginine group (7.19 +/- 1.5 vs. 7.27 +/- 1.5, P = 0.67). ADMA levels significantly increased compared to baseline after FMD1 (0.59 +/- 0.12-0.91 +/- 0.64 mu mol/l, P = 0.036), with similar changes in the two groups. FMD assessment induces a significant impairment of endothelial function. An increase of endogenous NO synthesis inhibitors seems responsible for the phenomenon that is reversed by L-arginine administration.
引用
收藏
页码:524 / 529
页数:6
相关论文
共 50 条
  • [21] Endothelial Function Assessment by Flow-Mediated Dilation Method: A Valuable Tool in the Evaluation of the Cardiovascular System
    Mucka, Szymon
    Miodonska, Martyna
    Jakubiak, Grzegorz K.
    Starzak, Monika
    Cieslar, Grzegorz
    Stanek, Agata
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (18)
  • [22] Flow-mediated dilation analysis coupled with nitric oxide transport to enhance the assessment of endothelial function
    Ma, Tianxiang
    Liu, Xiao
    Ren, Quan
    Zhang, Zhexi
    Sun, Xiaoning
    Zheng, Yuehong
    Deng, Xiaoyan
    Yu, Xiaojun
    Fan, Yubo
    JOURNAL OF APPLIED PHYSIOLOGY, 2021, 131 (01) : 1 - 14
  • [23] Adverse Impact of Mood on Flow-Mediated Dilation
    Cooper, Denise C.
    Milic, Milos S.
    Tafur, Joseph R.
    Mills, Paul J.
    Bardwell, Wayne A.
    Ziegler, Michael G.
    Dimsdale, Joel E.
    PSYCHOSOMATIC MEDICINE, 2010, 72 (02): : 122 - 127
  • [24] Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
    Machin, Daniel R.
    Leary, Miriam E.
    He, Yuxia
    Shiu, Yan-Ting
    Tanaka, Hirofumi
    Donato, Anthony J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (117):
  • [25] Comparison of two automatic methods for the assessment of brachial artery flow-mediated dilation
    Faita, Francesco
    Masi, Stefano
    Loukogeorgakis, Stavros
    Gemignani, Vincenzo
    Okorie, Mike
    Bianchini, Elisabetta
    Charakida, Marietta
    Demi, Marcello
    Ghiadoni, Lorenzo
    Deanfield, John Eric
    JOURNAL OF HYPERTENSION, 2011, 29 (01) : 85 - 90
  • [26] Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
    Thijssen, Dick H. J.
    Black, Mark A.
    Pyke, Kyra E.
    Padilla, Jaume
    Atkinson, Greg
    Harris, Ryan A.
    Parker, Beth
    Widlansky, Michael E.
    Tschakovsky, Michael E.
    Green, Daniel J.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 300 (01): : H2 - H12
  • [27] Endothelial function assessment: flow-mediated dilation and constriction provide different and complementary information on the presence of coronary artery disease
    Gori, Tommaso
    Muxel, Selina
    Damaske, Ana
    Radmacher, Marie-Christine
    Fasola, Federica
    Schaefer, Sarina
    Schulz, Andreas
    Jabs, Alexander
    Parker, John D.
    Muenzel, Thomas
    EUROPEAN HEART JOURNAL, 2012, 33 (03) : 363 - 371
  • [28] Flow-mediated dilation is associated with endothelial oxidative stress in human venous endothelial cells
    Gurovich, Alvaro N.
    Avery, Joseph C.
    Holtgrieve, Nicholas B.
    Braith, Randy W.
    VASCULAR MEDICINE, 2014, 19 (04) : 251 - 256
  • [29] Clinical Significance of Framingham Risk Score, Flow-Mediated Dilation and Pulse Wave Velocity in Patients With Stable Angina
    Park, Kyoung-Ha
    Kim, Min-Kyu
    Kim, Hyun-Sook
    Park, Woo Jung
    Cho, Goo-Yeong
    Choi, Young-Jin
    CIRCULATION JOURNAL, 2011, 75 (05) : 1177 - 1183
  • [30] Characterization of blood flow patterns and endothelial shear stress during flow-mediated dilation
    Morales-Acuna, Francisco
    Ochoa, Luis
    Valencia, Carolina
    Gurovich, Alvaro N.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2019, 39 (04) : 240 - 245