Transient endothelial dysfunction following flow-mediated dilation assessment

被引:15
|
作者
Nerla, Roberto [2 ]
Di Monaco, Antonio [2 ]
Sestito, Alfonso [2 ]
Lamendola, Priscilla [2 ]
Di Stasio, Enrico [3 ]
Romitelli, Federica [3 ]
Lanza, Gaetano Antonio [1 ,2 ]
Crea, Filippo [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Ist Cardiol, I-00168 Rome, Italy
[2] Univ Cattolica Sacro Cuore, Dipartimento Med Cardiovasc, I-00168 Rome, Italy
[3] Univ Cattolica Sacro Cuore, Ist Biochim & Biochim Clin, I-00168 Rome, Italy
关键词
Flow mediated dilation; Arginine; Endothelial function; CORONARY-ARTERY-DISEASE; NITRIC-OXIDE SYNTHESIS; ASYMMETRIC DIMETHYLARGININE; CARDIOVASCULAR RISK; L-ARGININE; ENDOGENOUS INHIBITOR; BRACHIAL-ARTERY; DIMETHYLAMINOHYDROLASE; VASODILATION; AUGMENTATION;
D O I
10.1007/s00380-010-0087-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Flow-mediated dilation (FMD) is a widely used tool to investigate endothelial function. However, FMD assessment may cause mechanical damage to the arterial endothelium. In this study we investigated the effect of FMD assessment on endothelial function. We studied 20 healthy subjects (26 +/- 6 years; 12 males). FMD was assessed by measuring brachial artery dilation in response to hyperemia after 5 min of forearm cuff inflation. Subjects were studied on 2 subsequent days. On day 1 they underwent two consecutive FMD measures, with the second test (FMD2) performed 15 min after the first test (FMD1). On day 2, the subjects were randomized to receive either placebo (saline) or intravenous L-arginine (10 g in 20 min). At the end of the infusion, patients underwent two consecutive FMD measures following the same protocol as on day 1. Asymmetric dimethyl-arginine (ADMA) serum levels were assessed on day 2 before FMD1 and FMD2. On day 1, FMD2 was lower than FMD1 in both groups (placebo 6.47 +/- 2.1 vs. 7.86 +/- 1.8%, P < 0.01; arginine 6.13 +/- 2.6 vs. 7.76 +/- 2.7%, P < 0.01). On day 2, a significant reduction of FMD was observed during FMD2 compared to FMD1 in the placebo group (5.82 +/- 1.7 vs. 7.44 +/- 2.2%, P < 0.001), but not in the arginine group (7.19 +/- 1.5 vs. 7.27 +/- 1.5, P = 0.67). ADMA levels significantly increased compared to baseline after FMD1 (0.59 +/- 0.12-0.91 +/- 0.64 mu mol/l, P = 0.036), with similar changes in the two groups. FMD assessment induces a significant impairment of endothelial function. An increase of endogenous NO synthesis inhibitors seems responsible for the phenomenon that is reversed by L-arginine administration.
引用
收藏
页码:524 / 529
页数:6
相关论文
共 50 条
  • [1] Transient endothelial dysfunction following flow-mediated dilation assessment
    Roberto Nerla
    Antonio Di Monaco
    Alfonso Sestito
    Priscilla Lamendola
    Enrico Di Stasio
    Federica Romitelli
    Gaetano Antonio Lanza
    Filippo Crea
    Heart and Vessels, 2011, 26 : 524 - 529
  • [2] Evaluation of endothelial dysfunction: Flow-mediated dilation
    Korkmaz, Hasan
    Onalan, Orhan
    ENDOTHELIUM-JOURNAL OF ENDOTHELIAL CELL RESEARCH, 2008, 15 (04): : 157 - 163
  • [3] Flow-Mediated Dilation As a Marker of Endothelial Dysfunction in Gout
    Calvo Aranda, Enrique
    Carrion, Ofelia
    Abdelkader, Afnan
    Gonzalez Martin, Jorge Juan
    Aramburu, Francisco
    Valero, Marta
    Rodriguez, Silvia
    Marin, Carolina
    Amil, Irene
    Sainz, Felipe
    Garcia De la Pena, Paloma
    ARTHRITIS & RHEUMATOLOGY, 2017, 69
  • [4] FLOW-MEDIATED DILATION AS A MARKER OF ENDOTHELIAL DYSFUNCTION IN GOUT
    Calvo Aranda, E.
    OSTEOPOROSIS INTERNATIONAL, 2018, 29 : S188 - S189
  • [5] Flow-Mediated Dilation (FMD) and Peripheral Endothelial Function Assessment
    Shechter, Michael
    JOURNAL OF VASCULAR RESEARCH, 2019, 56 : 100 - 100
  • [6] Endothelial Dysfunction Assessed with Flow-Mediated Dilation Is a Predictor of Neuropathy in Diabetes
    Roustit, Matthieu
    Loader, Jordan
    Baltzis, Dimitrios
    Deusen-Bery, Carly
    Veves, Aristidis
    DIABETES, 2016, 65 : A154 - A154
  • [7] Ultrasound Assessment of Flow-Mediated Dilation
    Harris, Ryan A.
    Nishiyama, Steven K.
    Wray, D. Walter
    Richardson, Russell S.
    HYPERTENSION, 2010, 55 (05) : 1075 - 1085
  • [8] Flow-mediated dilation of the brachial artery and endothelial dysfunction in different COPD phenotypes
    Dugac, Andrea Vukic
    Ruzic, Alen
    Popovic-Grle, Sanja
    Hecimovic, Ana
    Makek, Mateja Jankovic
    Samarzija, Miroslav
    Jakopovic, Marko
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [9] Flow-mediated dilation as a marker of endothelial dysfunction in pulmonary diseases: A narrative review
    Abagnale, Lucia
    Candia, Claudio
    Motta, Andrea
    Galloway, Brurya
    Ambrosino, Pasquale
    Molino, Antonio
    Maniscalco, Mauro
    RESPIRATORY MEDICINE AND RESEARCH, 2023, 84
  • [10] Endothelial dysfunction by flow-mediated dilation assessed ultrasonically in patients with Kawasaki Disease
    Koibuchi, Harumi
    Kotani, Kazuhiko
    Minami, Takaomi
    Konno, Kei
    Taniguchi, Nobuyuki
    MINERVA PEDIATRICA, 2016, 68 (02) : 143 - 147