A systematic review on diagnostic accuracy of CT-based detection of significant coronary artery disease

被引:116
作者
d'Othee, Bertrand Janne [1 ]
Siebert, Uwe [2 ,3 ,4 ]
Cury, Ricardo [3 ]
Jadvar, Hossein [5 ]
Dunn, Edward J. [6 ]
Hoffmann, Udo [3 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Inst Technol Assessment, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Dept Radiol, Massachusetts Gen Hosp, Boston, MA 02215 USA
[4] Univ Hlth Sci Med Informat & Technol, Dept Publ Hlth Med Decis Making & Hlth Technol As, Innsbruck, Austria
[5] Univ So Calif, Keck Sch Med, Dept Radiol, Los Angeles, CA 90033 USA
[6] Vet Hlth Adm, Natl Ctr Patient Safety, Ann Arbor, MI USA
关键词
coronary disease; imaging; computed tomography; meta-analysis;
D O I
10.1016/j.ejrad.2007.05.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Systematic review of diagnostic accuracy of contrast enhanced coronary computed tomography (CE-CCT). Background: Noninvasive detection of coronary artery stenosis (CAS) by CE-CCT as an alternative to catheter-based coronary angiography (CCA) may improve patient management. Methods: Forty-one articles published between 1997 and 2006 were included that evaluated native coronary arteries for significant stenosis and used CE-CCT as diagnostic test and CCA as reference standard. Study group characteristics, study methodology and diagnostic outcomes were extracted. Pooled summary sensitivity and specificity of CE-CCT were calculated using a random effects model (1) for all coronary segments, (2) assessable segments, and (3) per patient. Results: The 41 studies totaled 2515 patients (75% males; mean age: 59 years, CAS prevalence: 59%). Analysis of all coronary segments yielded a sensitivity of 95% (80%, 89%, 86%, 98% for electron beam CT, 4/8-slice, 16-slice and 64-slice MDCT, respectively) for a specificity of 85% (77%, 84%, 95%,91%). Analysis limited to segments deemed assessable by CT showed sensitivity of 96% (86%, 85%,98%,97%) for a specificity of 95% (90%, 96%, 96%, 96%). Per patient, sensitivity was 99% (90%, 97%, 99%, 98%) and specificity was 76% (59%, 81%, 83%, 92%). Heterogeneity was quantitatively important but not explainable by patient group characteristics or study methodology. Conclusions: Current diagnostic accuracy of CE-CCT is high. Advances in CT technology have resulted in increases in diagnostic accuracy and proportion of assessable coronary segments. However, per patient, accuracy may be lower and CT may have more limited clinical utility in populations at high risk for CAD. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:449 / 461
页数:13
相关论文
共 60 条
  • [1] Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction
    Achenbach, S
    Ropers, D
    Regenfus, M
    Muschiol, G
    Daniel, WG
    Moshage, W
    [J]. HEART, 2000, 84 (05) : 489 - 493
  • [2] Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation
    Achenbach, S
    Ropers, D
    Pohle, FK
    Raaz, D
    von Erffa, J
    Yilmaz, A
    Muschiol, G
    Daniel, WG
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 (19) : 1978 - 1986
  • [3] Detection of high-grade restenosis after PTCA using contrast-enhanced electron beam CT
    Achenbach, S
    Moshage, W
    Bachmann, K
    [J]. CIRCULATION, 1997, 96 (09) : 2785 - 2788
  • [4] Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions
    Achenbach, S
    Moshage, W
    Ropers, D
    Nossen, J
    Daniel, WG
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) : 1964 - 1971
  • [5] Achenbach S, 2001, CIRCULATION, V103, P2535
  • [6] [Anonymous], 2001, SYSTEMATIC REV HLTH
  • [7] Austen W G, 1975, Circulation, V51, P5
  • [8] Detection of coronary artery stenoses with multislice helical CT angiography
    Becker, CR
    Knez, A
    Leber, A
    Treede, H
    Ohnesorge, B
    Schoepf, UJ
    Reiser, MF
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) : 750 - 755
  • [9] Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography
    Budoff, MJ
    Oudiz, RJ
    Zalace, CP
    Bakhsheshi, H
    Goldberg, SL
    French, WJ
    Rami, TG
    Brundage, BH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) : 840 - 845
  • [10] Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography
    Budoff, MJ
    Achenbach, S
    Duerinckx, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) : 1867 - 1878