Donor-site morbidity following breast reconstruction with a latissimus dorsi flap - A prospective study

被引:2
|
作者
Hojvig, Jens H. [1 ]
Henriksen, Marius [2 ]
Bartholdy, Cecilie R. [2 ]
Bonde, Christian T. [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Plast Surg & Burns Treatment, Blegdamsvej 60,Afsnit 9441, DK-2100 Copenhagen O, Denmark
[2] Bispebjerg & Frederiksberg Hosp, Parker Inst, Copenhagen, Denmark
来源
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY | 2022年 / 75卷 / 07期
关键词
Breast reconstruction; Reconstructive surgery; Flap surgery; LD breast reconstruction; Latissimus dorsi; Plastic surgery; SHOULDER FUNCTION; FUNCTIONAL-EVALUATION; PERSISTENT PAIN; PROSTHESIS; MASTECTOMY; HARVEST;
D O I
10.1016/j.bjps.2022.01.036
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Despite a trend toward the use of perforator-based flaps for autologous breast reconstruction, the m. latissimus dorsi (LD) flap remains a popular alternative. Several studies have sought to uncover the shoulder-related donor-site morbidity, but the results are inconclusive. This study aims at evaluating what impact breast reconstruction with an LD flap has on shoulder strength, range of motion (ROM), lymphedema, sensory disturbances, and patients' ability to perform activities of daily living (ADL). Materials and methods: In a prospective observational study, we examined 20 female patients undergoing delayed breast reconstruction with an LD flap. The primary outcome was a change in shoulder strength, measured with the Biodex System4 Pro-dynamometer. ROM was assessed using two-dimensional photogrammetry. Furthermore, the patients' self-reported pain, lymphedema, sensory disturbances, and ability to perform ADL were assessed using a questionnaire. Measurements were performed pre-operatively at 3 months and 12 months postoperatively. Results: Of the 20 included patients, 17 completed the follow-up. At the 12 months followup, a significant loss of isometric shoulder strength of 17% was observed in shoulder adduction (P <0.001) and 21% in extension (P <0.001). Isometric strength and ability to perform ADL and ROM were unchanged. There was a decrease in the number of patients reporting problems with lymphedema (10 to 7) and an increase in the incidence of sensory disturbances (10 to 13). Conclusion: A loss of shoulder strength was observed following the transfer of the LD flap; however, the procedure did not hinder the post-operative performance of ADLs for the patients. LD reconstruction seems to be a safe procedure. (C) 2022 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd.
引用
收藏
页码:2205 / 2210
页数:6
相关论文
共 50 条
  • [21] Donor-Site Satisfaction of DIEP and Latissimus Dorsi Flaps-A Comparative Cohort Study
    Lofstrand, Jonas
    Paganini, Anna
    Liden, Mattias
    Hansson, Emma
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2023, 39 (06) : 472 - 481
  • [22] Preference for donor site scar orientation in pedicled latissimus dorsi breast reconstruction
    Ngan P.G.
    Jayagopal S.
    George E.N.
    McGeorge D.
    Juma A.
    European Journal of Plastic Surgery, 2007, 30 (4) : 189 - 194
  • [23] Breast reconstruction with the denervated latissimus dorsi musculocutaneous flap
    Szychta, Pawel
    Butterworth, Mark
    Dixon, Mike
    Kulkarni, Dhananjay
    Stewart, Ken
    Raine, Cameron
    BREAST, 2013, 22 (05): : 667 - 672
  • [24] Enhanced recovery after breast reconstruction with a pedicled Latissimus Dorsi flap-A prospective clinical study *
    Hojvig, Jens H.
    Kehlet, Henrik
    Bonde, Christian T.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2021, 74 (08): : 1725 - 1730
  • [25] Latissimus Dorsi Flap in Breast Reconstruction: Recent Innovations in the Workhorse Flap
    Sood, Rachita
    Easow, Jeena M.
    Konopka, Geoffrey
    Panthaki, Zubin J.
    CANCER CONTROL, 2018, 25 (01)
  • [26] Encysted haematoma formation following a latissimus dorsi flap-based breast reconstruction
    Fayyaz A. K. Mazari
    Akin Rae
    Ashleigh Genever
    Iman A. Azmy
    European Journal of Plastic Surgery, 2016, 39 (4) : 317 - 318
  • [27] Minimizing free flap donor-site morbidity
    Harris, Brianna N.
    Bewley, Arnaud F.
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2016, 24 (05): : 447 - 452
  • [28] Extension or combination of an autologous latissimus dorsi flap in breast reconstruction
    Lundberg, Jonas
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2009, 43 (01): : 16 - 21
  • [29] Latissimus Dorsi Donor-Site Morbidity The Combination of Quilting and Fibrin Sealant Reduce Length of Drain Placement and Seroma Rate
    Bailey, Steven H.
    Oni, Georgette
    Guevara, Rafael
    Wong, Corrine
    Saint-Cyr, Michel
    ANNALS OF PLASTIC SURGERY, 2012, 68 (06) : 555 - 558
  • [30] Total autologous breast reconstruction with the Kiss Latissimus Dorsi Flap
    Brunetti, Beniamino
    Salzillo, Rosa
    Tenna, Stefania
    Cagli, Barbara
    Coppola, Morelli M.
    Petrucci, Valeria
    Camilloni, Chiara
    Zhang, Yi Xin
    Persichetti, Paolo
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (10): : 3673 - 3682