Advanced data readout technique for Multianode Position Sensitive Photomultiplier Tube applicable in radiation imaging detectors

被引:7
作者
Popov, V. [1 ]
机构
[1] Thomas Jefferson Natl Accelerator Facil, Newport News, VA USA
来源
JOURNAL OF INSTRUMENTATION | 2011年 / 6卷
关键词
Analogue electronic circuits; Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Front-end electronics for detector readout;
D O I
10.1088/1748-0221/6/01/C01061
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Most of the best performing PSPMT tubes from Hamamatsu and Burle are designed with a pad-matrix anode layout. However, for obtaining a high resolution, a small-sized anode photomultiplier tubes are preferable; these tubes may have 64, 256 or 1024 anodes per tube. If the tubes are used in array to get a larger area detector, the number of analog channels may range from hundreds to thousands. Multichannel analog readout requires special electronics ICs, ASICs etc., which are attached to multichannel DAQ system. As a result, the data file and data processing time will be increased. Therefore, this readout could not be performed in a small project. Usually, most of radiation imaging applications allow the use of analog data processing in front-end electronics, significantly reducing the number of the detector's output lines to data acquisition without reducing the image quality. The idea of pad-matrix decoupling circuit with gain correction was invented and intensively tested in JLab. Several versions of PSPMT readout electronics were produced and studied. All developments were done and optimized specifically for radiation imaging projects. They covered high resolution SPECT, high speed PET, fast neutron imaging, and single tube and multi tube array systems. This paper presents and discusses the summary of the observed results in readout electronics evaluation with different PSPMTs and radiation imaging systems, as well as the advantages and limitations of the developed approach to radiation imaging detectors readout.
引用
收藏
页数:10
相关论文
共 12 条
  • [1] Cherry S.R., US Patent, Patent No. [5,719,400, 5719400]
  • [2] Popov V, 2002, IEEE NUCL SCI CONF R, P1937, DOI 10.1109/NSSMIC.2001.1009203
  • [3] Popov V., 2003, NUCL SCI S C RECORD, V3, P2156, DOI DOI 10.1109/NSSMIC.2003.1352307
  • [4] Popov V., [No title captured], Patent No. [U.S. Patent, 6,747,263, 6747263]
  • [5] POPOV V, 2006, IEEE MED IM C SAN DI
  • [6] A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout
    Popov, Vladimir
    Majewski, Stan
    Welch, Benjamin L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01) : 319 - 322
  • [7] A Compact High Performance Readout Electronics Solution for H9500 Hamamatsu 256 Multianode Photomultiplier Tube for Application in Gamma Cameras
    Popov, Vladimir
    Majewski, Stan
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2981 - 2985
  • [8] Proffitt J, 2005, IEEE NUCL SCI CONF R, P2971
  • [9] Implementation of a High-Rate USB Data Acquisition System for PET and SPECT Imaging
    Proffitt, J.
    Hammond, W.
    Majewski, S.
    Popov, V.
    Raylman, R. R.
    Weisenberger, A. G.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3063 - 3067
  • [10] The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements
    Raylman, Raymond R.
    Majewski, Stan
    Smith, Mark F.
    Proffitt, James
    Hammond, William
    Srinivasan, Amarnath
    McKisson, John
    Popov, Vladimir
    Weisenberger, Andrew
    Judy, Clifford O.
    Kross, Brian
    Ramasubramanian, Srikanth
    Banta, Larry E.
    Kinahan, Paul E.
    Champley, Kyle
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (03) : 637 - 653