Combined stent-retriever and aspiration intra-arterial thrombectomy performance for fragmentable blood clots: A proof-of-concept computational study

被引:9
作者
Luraghi, Giulia [1 ,2 ]
Bridio, Sara [1 ]
Lissoni, Vittorio [1 ]
Dubini, Gabriele [1 ]
Dwivedi, Anushree [3 ]
McCarthy, Ray [3 ]
Fereidoonnezhad, Behrooz [2 ,4 ]
McGarry, Patrick [4 ]
Gijsen, Frank J. H. [2 ,5 ]
Matas, Jose Felix Rodriguez [1 ]
Migliavacca, Francesco [1 ]
机构
[1] Politecn Milan, Dept Chem Mat & Chem Engn Giulio Natta, Milan, Italy
[2] Delft Univ Technol, Dept Biomech Engn, Delft, Netherlands
[3] Cerenovus, Neuro Technol Ctr, Galway, Ireland
[4] Natl Univ Ireland Galway, Dept Biomed Engn, Galway, Ireland
[5] Erasmus MC, Thoraxctr, Dept Biomed Engn, Rotterdam, Netherlands
关键词
Thrombectomy; Acute ischemic stroke; Stent-retriever; Finite element analysis; MECHANICAL THROMBECTOMY;
D O I
10.1016/j.jmbbm.2022.105462
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mechanical thrombectomy (MT) treatment of acute ischemic stroke (AIS) patients typically involves use of stent retrievers or aspiration catheters alone or in combination. For in silico trials of AIS patients, it is crucial to incorporate the possibility of thrombus fragmentation during the intervention. This study focuses on two aspects of the thrombectomy simulation: i) Thrombus fragmentation on the basis of a failure model calibrated with experimental tests on clot analogs; ii) the combined stent-retriever and aspiration catheter MT procedure is modeled by adding both the proximal balloon guide catheter and the distal access catheter.The adopted failure criterion is based on maximum principal stress threshold value. If elements of the thrombus exceed this criterion during the retrieval simulation, then they are deleted from the calculation.Comparison with in-vitro tests indicates that the simulation correctly reproduces the procedures predicting thrombus fragmentation in the case of red blood cells rich thrombi, whereas non-fragmentation is predicted for fibrin-rich thrombi. Modeling of balloon guide catheter prevents clot fragments' embolization to further distal territories during MT procedure.
引用
收藏
页数:11
相关论文
共 43 条
  • [1] A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke
    Berkhemer, O. A.
    Fransen, P. S. S.
    Beumer, D.
    van den Berg, L. A.
    Lingsma, H. F.
    Yoo, A. J.
    Schonewille, W. J.
    Vos, J. A.
    Nederkoorn, P. J.
    Wermer, M. J. H.
    van Walderveen, M. A. A.
    Staals, J.
    Hofmeijer, J.
    van Oostayen, J. A.
    Nijeholt, G. J. Lycklama A.
    Boiten, J.
    Brouwer, P. A.
    Emmer, B. J.
    de Bruijn, S. F.
    van Dijk, L. C.
    Kappelle, L. J.
    Lo, R. H.
    Van Dijk, E. J.
    de Vries, J.
    de Kort, P. L. M.
    van Rooij, W. J. J.
    van den Berg, J. S. P.
    van Hasselt, B. A. A. M.
    Aerden, L. A. M.
    Dallinga, R. J.
    Visser, M. C.
    Bot, J. C. J.
    Vroomen, P. C.
    Eshghi, O.
    Schreuder, T. H. C. M. L.
    Heijboer, R. J. J.
    Keizer, K.
    Tielbeek, A. V.
    den Hertog, H. M.
    Gerrits, D. G.
    van den Berg-Vos, R. M.
    Karas, G. B.
    Steyerberg, E. W.
    Flach, H. Z.
    Marquering, H. A.
    Sprengers, M. E. S.
    Jenniskens, S. F. M.
    Beenen, L. F. M.
    van den Berg, R.
    Koudstaal, P. J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 372 (01) : 11 - 20
  • [2] Impact of the Internal Carotid Artery Morphology on in silico Stent-Retriever Thrombectomy Outcome
    Bridio, Sara
    Luraghi, Giulia
    Matas, Jose Rodriguez F.
    Dubini, Gabriele
    Giassi, Giorgia G.
    Maggio, Greta
    Kawamoto, Julia N.
    Moerman, Kevin M.
    McGarry, Patrick
    Konduri, Praneeta R.
    Terreros, Nerea Arrarte
    Marquering, Henk A.
    van Bavel, Ed
    Majoie, Charles B. L. M.
    Migliavacca, Francesco
    [J]. FRONTIERS IN MEDICAL TECHNOLOGY, 2021, 3
  • [3] Anterior cerebral artery embolism during thrombectomy increases disability and mortality
    Chalumeau, Vanessa
    Blanc, Raphael
    Redjem, Hocine
    Ciccio, Gabriele
    Smajda, Stanislas
    Desilles, Jean-Philippe
    Botta, Daniele
    Escalard, Simon
    Boisseau, William
    Maier, Benjamin
    Labreuche, Julien
    Obadia, Mickael
    Piotin, Michel
    Mazighi, Mikael
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (11) : 1057 - 1062
  • [4] Three-Dimensional Numerical Simulations of Aspiration Process: Evaluation of Two Penumbra Aspiration Catheters Performance
    Chitsaz, Alireza
    Nejat, Amir
    Nouri, Reza
    [J]. ARTIFICIAL ORGANS, 2018, 42 (12) : E406 - E419
  • [5] Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy
    Chueh, Ju-Yu
    Kang, Dong-Hun
    Kim, Byung Moon
    Gounis, Matthew J.
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2020, 63 (01) : 14 - 25
  • [6] Tri-axial system using the Solitaire-FR and Penumbra Aspiration Microcatheter for acute mechanical thrombectomy
    Deshaies, Eric M.
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (09) : 1303 - 1305
  • [7] Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke
    Duffy, Sharon
    Farrell, Michael
    McArdle, Kevin
    Thornton, John
    Vale, David
    Rainsford, Eleanor
    Morris, Liam
    Liebeskind, David S.
    MacCarthy, Eugene
    Gilvarry, Michael
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (05) : 486 - +
  • [8] Dumont T.M., 2014, J NEUROINTERV SURG, V6, DOI [10.1136/NEURINTSURG-2012-010624, DOI 10.1136/NEURINTSURG-2012-010624]
  • [9] A new constitutive model for permanent deformation of blood clots with application to simulation of aspiration thrombectomy
    Fereidoonnezhad, Behrooz
    McGarry, Patrick
    [J]. JOURNAL OF BIOMECHANICS, 2022, 130
  • [10] Blood clot fracture properties are dependent on red blood cell and fibrin content
    Fereidoonnezhad, Behrooz
    Dwivedi, Anushree
    Johnson, Sarah
    McCarthy, Ray
    McGarry, Patrick
    [J]. ACTA BIOMATERIALIA, 2021, 127 : 213 - 228