C60 Secondary Ion Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

被引:46
作者
Smith, Donald F. [1 ]
Robinson, Errol W. [1 ]
Tolmachev, Aleksey V. [2 ]
Heeren, Ron M. A. [3 ]
Pasa-Tolic, Ljiljana [1 ]
机构
[1] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Fundamental & Computat Sci Div, Richland, WA 99352 USA
[3] FOM Inst Atom & Mol Phys AMOLF, NL-1098 XG Amsterdam, Netherlands
关键词
DESORPTION IONIZATION; CLUSTER SIMS; DISSOCIATION; SOLIDS; SYSTEM; TISSUE;
D O I
10.1021/ac2023348
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Secondary ion mass spectrometry (SIMS) has seen increased application for high spatial resolution chemical imaging of complex biological surfaces. The advent and commercial availability of cluster and polyatomic primary ion sources (e.g., Au and Bi cluster and buckminsterfullerene (C-60)) provide improved secondary ion yield and decreased fragmentation of surface species, thus improving accessibility of intact molecular ions for SIMS analysis. However, full exploitation of the advantages of these new primary ion sources has been limited, due to the use of low mass resolution mass spectrometers without tandem MS to enable enhanced structural identification capabilities. Similarly, high mass resolution and high mass measurement accuracy would greatly improve the chemical specificity of SIMS. Here we combine, for the first time, the advantages of a C-60 primary ion source with the ultrahigh mass resolving power and high mass measurement accuracy of Fourier transform ion cyclotron resonance mass spectrometry. Mass resolving power in excess of 100 000 (m/Delta m(50%)) is demonstrated, with a root-mean-square mass measurement accuracy below 1 part-per-million. Imaging of mouse brain tissue at 40 mu m pixel size is shown. Tandem mass spectrometry of ions from biological tissue is demonstrated and molecular formulas were assigned for fragment ion identification.
引用
收藏
页码:9552 / 9556
页数:5
相关论文
共 40 条
[1]   CESIUM ION DESORPTION IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
AMSTER, IJ ;
LOO, JA ;
FURLONG, JJP ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :313-317
[2]  
[Anonymous], 2001, ToF-SIMS: Surface Analysis by Mass Spectrometry
[3]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[4]   SURFACE INVESTIGATION OF SOLIDS BY STATICAL METHOD OF SECONDARY ION MASS SPECTROSCOPY (SIMS) [J].
BENNINGHOVEN, A .
SURFACE SCIENCE, 1973, 35 (01) :427-457
[5]   Lipid imaging with cluster time-of-flight secondary ion mass spectrometry [J].
Brunelle, Alain ;
Laprevote, Olivier .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :31-35
[6]   Cluster SIMS with a hybrid quadrupole time-of-light mass spectrometer [J].
Carado, A. ;
Kozole, J. ;
Passarelli, M. ;
Winograd, N. ;
Loboda, A. ;
Wingate, J. .
APPLIED SURFACE SCIENCE, 2008, 255 (04) :1610-1613
[7]   Biological tissue imaging with a hybrid cluster SIMS quadrupole time-of-flight mass spectrometer [J].
Carado, A. ;
Kozole, J. ;
Passarelli, M. ;
Winograd, N. ;
Loboda, A. ;
Bunch, J. ;
Wingate, J. ;
Hankin, J. ;
Murphy, R. .
APPLIED SURFACE SCIENCE, 2008, 255 (04) :1572-1575
[8]   C60 Secondary Ion Mass Spectrometry with a Hybrid-Quadrupole Orthogonal Time-of-Flight Mass Spectrometer [J].
Carado, Anthony ;
Passarelli, M. K. ;
Kozole, Joseph ;
Wingate, J. E. ;
Winograd, Nicholas ;
Loboda, A. V. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :7921-7929
[9]   CESIUM ION DESORPTION IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
CASTRO, ME ;
RUSSELL, DH .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :578-581
[10]   Subcellular imaging by dynamic SIMS ion microscopy [J].
Chandra, S ;
Smith, DR ;
Morrison, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :104A-114A