We acquired polarization-sensitive reflectance images in freshly excised skeletal muscle samples. The obtained raw images varied depending on the incident and detection polarization states. The Stokes vectors were measured for incident light of four different polarization states, and the whole Mueller matrix images were also calculated. We found that the images obtained in skeletal muscles exhibited different features from those obtained in a typical polystyrene sphere solution. The back-reflected light in muscle maintained a higher degree of polarization along the axis perpendicular to muscle fiber orientation. Our analysis indicates that the unique muscle sarcomere structure plays an important role in modulating the propagation of polarized light in whole muscle. (c) 2008 Optical Society of America.
引用
收藏
页码:9927 / 9935
页数:9
相关论文
共 26 条
[1]   Development and calibration of an automated Mueller matrix polarization imaging system [J].
Baba, JS ;
Chung, JR ;
DeLaughter, AH ;
Cameron, BD ;
Coté, GL .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (03) :341-349
[2]   Polarized light scattering spectroscopy for quantitative measurement of epithelial cellular structures in situ [J].
Backman, V ;
Gurjar, R ;
Badizadegan, K ;
Itzkan, L ;
Dasari, RR ;
Perelman, LT ;
Feld, MS .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1019-1026
[3]  
Bönnemann CG, 2004, CURR OPIN NEUROL, V17, P529
[4]   Characterization of backscattering Mueller matrix patterns of highly scattering media with triple scattering assumption [J].
Deng, Yong ;
Zeng, Shaoqun ;
Lu, Qiang ;
Zhu, Dan ;
Luo, Qingming .
OPTICS EXPRESS, 2007, 15 (15) :9672-9680
[5]   Diffuse backscattering Mueller matrices of highly scattering media [J].
Hielscher, Andreas H. ;
Eick, Angelia A. ;
Mourant, Judith R. ;
Shen, Dan ;
Freyer, James P. ;
Bigio, Irving J. .
OPTICS EXPRESS, 1997, 1 (13) :441-453
[6]   Depth-resolved two-dimensional Stokes vectors of backscattered light and Mueller matrices of biological tissue measured with optical coherence tomography [J].
Jiao, SL ;
Yao, G ;
Wang, LHV .
APPLIED OPTICS, 2000, 39 (34) :6318-6324
[7]   Polarized wavelength-dependent measurements of turbid media [J].
Johnson, TM ;
Mourant, JR .
OPTICS EXPRESS, 1999, 4 (06) :200-216
[8]   When contractile proteins go bad: the sarcomere and skeletal muscle disease [J].
Laing, NG ;
Nowak, KJ .
BIOESSAYS, 2005, 27 (08) :809-822
[9]   Implications of muscle design on surgical reconstruction of upper extremities [J].
Lieber, RL ;
Fridén, J .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (419) :267-279
[10]   3-DIMENSIONAL VECTOR COUPLED-WAVE ANALYSIS OF PLANAR-GRATING DIFFRACTION [J].
MOHARAM, MG ;
GAYLORD, TK .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1983, 73 (09) :1105-1112