Inverse field-based approach for simultaneous B1 mapping at high fields - A phantom based study

被引:8
作者
Jin, Jin [1 ]
Liu, Feng [1 ]
Zuo, Zhentao [2 ]
Xue, Rong [2 ]
Li, Mingyan [1 ]
Li, Yu [1 ]
Weber, Ewald [1 ]
Crozier, Stuart [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Chinese Acad Sci, Inst Biophys, State Key Lab Brain & Cognit Sci, Beijing MRI Ctr Brain Res, Beijing 100080, Peoples R China
关键词
Transmit sensitivity mapping; Receive sensitivity (receptivity) mapping; B-1; Inverse method; Field-based approach; Signal intensity; Parallel imaging; SENSE; Iterative optimization; Method of moments (MoM); PARALLEL MRI; 7; T; SENSITIVITY; RECONSTRUCTION; COIL; INHOMOGENEITY; EXCITATION; LOSSY; ARRAY;
D O I
10.1016/j.jmr.2012.02.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Based on computational electromagnetics and multi-level optimization, an inverse approach of attaining accurate mapping of both transmit and receive sensitivity of radiofrequency coils is presented. This paper extends our previous study of inverse methods of receptivity mapping at low fields, to allow accurate mapping of RF magnetic fields (B-1) for high-field applications. Accurate receive sensitivity mapping is essential to image domain parallel imaging methods, such as sensitivity encoding (SENSE), to reconstruct high quality images. Accurate transmit sensitivity mapping will facilitate RF-shimming and parallel transmission techniques that directly address the RF inhomogeneity issue, arguably the most challenging issue of high-field magnetic resonance imaging (MRI). The inverse field-based approach proposed herein is based on computational electromagnetics and iterative optimization. It fits an experimental image to the numerically calculated signal intensity by iteratively optimizing the coil-subject geometry to better resemble the experiments. Accurate transmit and receive sensitivities are derived as intermediate results of the optimization process. The method is validated by imaging studies using homogeneous saline phantom at 7T. A simulation study at 300 MHz demonstrates that the proposed method is able to obtain receptivity mapping with errors an order of magnitude less than that of the conventional method. The more accurate receptivity mapping and simultaneously obtained transmit sensitivity mapping could enable artefact-reduced and intensity-corrected image reconstructions. It is hoped that by providing an approach to the accurate mapping of both transmit and receive sensitivity, the proposed method will facilitate a range of applications in high-field MRI and parallel imaging. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:27 / 35
页数:9
相关论文
共 45 条
[1]  
Ballester M.A.G., 2001, ANN M ISMRM GLASG
[2]  
Chang Y.V., 2011, MAGNETIC RESONANCE M
[3]   GPU Accelerated FDTD Solver and its Application in MRI [J].
Chi, J. ;
Liu, F. ;
Jin, J. ;
Mason, D. G. ;
Crozier, S. .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :3305-3308
[4]   GPU-Accelerated FDTD Modeling of Radio-Frequency Field-Tissue Interactions in High-Field MRI [J].
Chi, Jieru ;
Liu, Feng ;
Weber, Ewald ;
Li, Yu ;
Crozier, Stuart .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (06) :1789-1796
[5]   Central brightening due to constructive interference with, without, and despite dielectric resonance [J].
Collins, CM ;
Liu, WZ ;
Schreiber, W ;
Yang, QX ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) :192-196
[6]   Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz [J].
Collins, CM ;
Yang, QX ;
Wang, JH ;
Zhang, X ;
Liu, H ;
Michaeli, S ;
Zhu, XH ;
Adriany, G ;
Vaughan, JT ;
Anderson, P ;
Merkle, H ;
Ugurbil, K ;
Smith, MB ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1026-1028
[7]   Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1011-1020
[8]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[9]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914
[10]  
Hoult DI, 2000, CONCEPT MAGNETIC RES, V12, P173, DOI 10.1002/1099-0534(2000)12:4<173::AID-CMR1>3.0.CO