Full-scale measurements and damping ratio properties of cooling towers with typical heights and configurations

被引:15
|
作者
Ke, Shitang [1 ,2 ]
Yu, Wei [1 ]
Zhu, Peng [1 ]
Ge, Yaojun [2 ]
Hou, Xian'an [3 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Civil Engn, Nanjing 210016, Jiangsu, Peoples R China
[2] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
[3] Northwest Elect Power Design Inst, Dept Civil Engn Technol, China Power Engn Consulting Grp, Xian 710075, Shaanxi, Peoples R China
关键词
Cooling tower; Field measurement; Modal recognition; Natural frequency; Damping ratio; Error analysis; WIND PRESSURE DISTRIBUTION; MODEL; PERFORMANCE; BEHAVIOR; DAMAGE;
D O I
10.1016/j.tws.2017.12.024
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The standard damping ratio for cooling towers is equivalent to that of high-rise reinforced concrete structures, which is 5%. But considering the unique configuration and material properties of the cooling towers, the actual damping ratio of cooling towers is far smaller than the standard value. Damping ratio is an important input parameter for wind and seismic analyses, its value directly determines the anti-wind and anti-seismic safety of the cooling towers. However, few field tests and damping ratio experiments have been conducted for cooling towers at home and abroad. In this paper, we performed field tests of 8 cooling towers with typical height and configuration in the inland areas of China. Acceleration response signals (vibration signals) at typical points of the tower body were obtained under ambient excitation. The measured acceleration signals were preprocessed using the random decrement method (RDM) and natural excitation technique. The natural frequencies and damping ratios of the first ten modes were obtained by combining three modal recognition methods, namely, auto-regressive and moving average (ARMA) model, Ibrahim time domain (ITD), and spare time domain (STD). The measured values were compared against the results of finite element analysis (FEA) and the errors were assessed. Then the equivalent synthetic damping ratios of the 8 cooling towers were estimated based on modal combination. Finally we provided the calculation formulae for the damping ratios and equivalent synthetic damping ratios of the first ten modes by using the fundamental frequency as the objective function and the measured damping ratios of the 8 cooling towers. The measured frequencies were consistent with the results of FEA for the 8 cooling towers, and the maximum difference in fundamental frequency was 4.4%. The damping ratios recognized of each mode showed a dispersed distribution. The maximum damping ratio of the first ten modes was 2.86%. The equivalent synthetic damping ratios of the 8 cooling towers ranged from 1.13% to 2.16%. Error analysis indicated that the fitting formula for the damping ratio had high precision and high stability. The present research provides valuable clues for the determination of damping ratio for large cooling towers and enhances the understanding on the damping mechanism.
引用
收藏
页码:437 / 448
页数:12
相关论文
共 50 条
  • [1] Research of damping ratio characteristics and of full-scale measurements for large cooling towers under the ambient excitation
    Ke S.-T.
    Yu W.
    Zhu P.
    Hou X.-A.
    Yao Y.-C.
    Wang Z.-Y.
    Gao L.
    1600, Nanjing University of Aeronautics an Astronautics (33): : 35 - 46
  • [2] Modal parameter identification and damping ratio estimation from the full-scale measurements of a typical Tibetan wooden structure
    Lu Dai
    Na Yang
    S. S. Law
    Qingshan Yang
    Earthquake Engineering and Engineering Vibration, 2016, 15 : 681 - 695
  • [3] Modal parameter identification and damping ratio estimation from the full-scale measurements of a typical Tibetan wooden structure
    Dai Lu
    Yang Na
    S.S.Law
    Yang Qingshan
    EarthquakeEngineeringandEngineeringVibration, 2016, 15 (04) : 681 - 695
  • [4] Modal parameter identification and damping ratio estimation from the full-scale measurements of a typical Tibetan wooden structure
    Dai Lu
    Yang Na
    Law, S. S.
    Yang Qingshan
    Earthquake Engineering and Engineering Vibration, 2016, 15 (04) : 681 - 695
  • [5] Fluctuating wind pressure distribution around full-scale cooling towers
    Zhao, Lin
    Ge, Yaojun
    Kareem, Ahsan
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2017, 165 : 34 - 45
  • [6] Identification of damping ratio and its influences on wind- and earthquake-induced effects for large cooling towers
    Ke, S. T.
    Yu, W.
    Xu, L.
    Ge, Y. J.
    Tamura, Y.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (12)
  • [7] Damping assessment of monopole steel structures through full-scale experiments
    Pagnini, Luisa
    Orlando, Andrea
    Repetto, Maria Pia
    ENGINEERING STRUCTURES, 2025, 327
  • [8] FLUCTUATING WIND PRESSURE DISTRIBUTION AROUND FULL-SCALE COOLING TOWER
    Zhao, Lin
    Ge, Yaojun
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 847 - 852
  • [9] Effects of free-stream turbulence on wind loads on a full-scale large cooling tower
    Cheng, X. X.
    Dong, J.
    Peng, Y.
    Zhao, L.
    Ge, Y. J.
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (10) : 1437 - 1453
  • [10] Predominant period and equivalent viscous damping ratio identification for a full-scale building shake table test
    Chen, Michelle C.
    Astroza, Rodrigo
    Restrepo, Jose I.
    Conte, Joel P.
    Hutchinson, Tara
    Bock, Yehuda
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (14) : 2459 - 2477