Accurate detection of heart rate using in-ear photoplethysmography in a clinical setting

被引:4
作者
Adams, Tim [1 ]
Wagner, Sophie [1 ]
Baldinger, Melanie [2 ]
Zellhuber, Incinur [1 ]
Weber, Michael [1 ]
Nass, Daniel [3 ]
Surges, Rainer [3 ]
机构
[1] Cosinuss GmbH, Munich, Germany
[2] Tech Univ Munich, Sport Equipment & Sport Mat, Munich, Germany
[3] Univ Hosp Bonn, Dept Epileptol, Bonn, Germany
来源
FRONTIERS IN DIGITAL HEALTH | 2022年 / 4卷
关键词
validation; heart rate; photoplethysmography; in-ear; wearable sensor; continuous monitoring; epilepsy; EPILEPSY; RELIABILITY; AGREEMENT; VALIDITY; MONITORS; ADULTS;
D O I
10.3389/fdgth.2022.909519
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Recent research has shown that photoplethysmography (PPG) based wearable sensors offer a promising potential for chronic disease monitoring. The aim of the present study was to assess the performance of an in-ear wearable PPG sensor in acquiring valid and reliable heart rate measurements in a clinical setting, with epileptic patients. Methods: Patients undergoing video-electroencephalography (EEG) monitoring with concomitant one-lead electrocardiographic (ECG) recordings were equipped with an in-ear sensor developed by cosinuss degrees. Results: In total, 2,048 h of recording from 97 patients with simultaneous ECG and in-ear heart rate data were included in the analysis. The comparison of the quality-filtered in-ear heart rate data with the reference ECG resulted in a bias of 0.78 bpm with a standard deviation of +2.54 bpm; Pearson's Correlation Coefficient PCC = 0.83; Intraclass Correlation Coefficient ICC = 0.81 and mean absolute percentage error MAPE = 2.57%. Conclusion: These data confirm that the in-ear wearable PPG sensor provides accurate heart rate measurements in comparison with ECG under realistic clinical conditions, especially with a signal quality indicator. Further research is required to investigate whether this technology is helpful in identifying seizure-related cardiovascular changes.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Design of a Real-Time Heart Rate Monitoring System Using Photoplethysmography and Smartphone
    Singh, Neharika
    Prince, Aashirvad
    Chattopadhyay, Swarnendu
    Patra, Rusha
    Mukherjee, Banibrata
    IEEE INDICON: 15TH IEEE INDIA COUNCIL INTERNATIONAL CONFERENCE, 2018,
  • [32] A NEW APPROACH FOR HEART RATE MONITORING USING PHOTOPLETHYSMOGRAPHY SIGNALS CONTAMINATED BY MOTION ARTIFACTS
    Sun, Biao
    Feng, Hui
    Zhang, Zhilin
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 809 - 813
  • [33] A Heart Rate Monitoring Framework for Real-World Drivers Using Remote Photoplethysmography
    Huang, Po-Wei
    Wu, Bing-Jhang
    Wu, Bing-Fei
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (05) : 1397 - 1408
  • [34] Heart Rate Detection Using SVM Based on Video Imagery
    Zeng, Wu
    Sheng, Yi
    Hu, Qiuyu
    Huo, Zhanxiong
    Zhang, Yingge
    Xie, Yuxuan
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2022, 32 (01) : 377 - 387
  • [35] Stress Detection Using Low Cost Heart Rate Sensors
    Salai, Mario
    Vassanyi, Istvan
    Kosa, Istvan
    JOURNAL OF HEALTHCARE ENGINEERING, 2016, 2016
  • [36] Accurate neonatal heart rate monitoring using a new wireless, cap mounted device
    Henry, Caroline
    Shipley, Lara
    Ward, Carole
    Mirahmadi, Siavash
    Liu, Chong
    Morgan, Steve
    Crowe, John
    Carpenter, James
    Hayes-Gill, Barrie
    Sharkey, Don
    ACTA PAEDIATRICA, 2021, 110 (01) : 72 - 78
  • [37] Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects
    Weinschenk, Stefan W.
    Beise, Reinhard D.
    Lorenz, Juergen
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2016, 116 (08) : 1527 - 1535
  • [38] Heart rate variability (HRV) in deep breathing tests and 5-min short-term recordings: agreement of ear photoplethysmography with ECG measurements, in 343 subjects
    Stefan W. Weinschenk
    Reinhard D. Beise
    Jürgen Lorenz
    European Journal of Applied Physiology, 2016, 116 : 1527 - 1535
  • [39] Photoplethysmography-based estimation of heart rate recovery using a wrist-worn device
    Sokas, Daivaras
    Petrenas, Andrius
    Daukantas, Saulius
    Rapalis, Andrius
    Marozas, Vaidotas
    2018 16TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC), 2018,
  • [40] Accurate Heart Rate Detection from On-Body Continuous Wave Radar Sensors using Wavelet Transform
    Ebrahim, Malikeh Pour
    Heydari, Fatemeh
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    2018 IEEE SENSORS, 2018, : 1079 - 1082