Accurate detection of heart rate using in-ear photoplethysmography in a clinical setting

被引:4
作者
Adams, Tim [1 ]
Wagner, Sophie [1 ]
Baldinger, Melanie [2 ]
Zellhuber, Incinur [1 ]
Weber, Michael [1 ]
Nass, Daniel [3 ]
Surges, Rainer [3 ]
机构
[1] Cosinuss GmbH, Munich, Germany
[2] Tech Univ Munich, Sport Equipment & Sport Mat, Munich, Germany
[3] Univ Hosp Bonn, Dept Epileptol, Bonn, Germany
来源
FRONTIERS IN DIGITAL HEALTH | 2022年 / 4卷
关键词
validation; heart rate; photoplethysmography; in-ear; wearable sensor; continuous monitoring; epilepsy; EPILEPSY; RELIABILITY; AGREEMENT; VALIDITY; MONITORS; ADULTS;
D O I
10.3389/fdgth.2022.909519
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Recent research has shown that photoplethysmography (PPG) based wearable sensors offer a promising potential for chronic disease monitoring. The aim of the present study was to assess the performance of an in-ear wearable PPG sensor in acquiring valid and reliable heart rate measurements in a clinical setting, with epileptic patients. Methods: Patients undergoing video-electroencephalography (EEG) monitoring with concomitant one-lead electrocardiographic (ECG) recordings were equipped with an in-ear sensor developed by cosinuss degrees. Results: In total, 2,048 h of recording from 97 patients with simultaneous ECG and in-ear heart rate data were included in the analysis. The comparison of the quality-filtered in-ear heart rate data with the reference ECG resulted in a bias of 0.78 bpm with a standard deviation of +2.54 bpm; Pearson's Correlation Coefficient PCC = 0.83; Intraclass Correlation Coefficient ICC = 0.81 and mean absolute percentage error MAPE = 2.57%. Conclusion: These data confirm that the in-ear wearable PPG sensor provides accurate heart rate measurements in comparison with ECG under realistic clinical conditions, especially with a signal quality indicator. Further research is required to investigate whether this technology is helpful in identifying seizure-related cardiovascular changes.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Evaluation of a Wearable in-Ear Sensor for Temperature and Heart Rate Monitoring: A Pilot Study
    Ellebrecht, David Benjamin
    Gola, Damian
    Kaschwich, Mark
    JOURNAL OF MEDICAL SYSTEMS, 2022, 46 (12)
  • [12] Validation of Photoplethysmography Using a Mobile Phone Application for the Assessment of Heart Rate Variability in the Context of Heart Rate Variability-Biofeedback
    van Dijk, Willeke
    Huizink, Anja C.
    Oosterman, Mirjam
    Lemmers-Jansen, Imke L. J.
    de Vente, Wieke
    PSYCHOSOMATIC MEDICINE, 2023, 85 (07): : 568 - 576
  • [13] Sleep detection in heart rate signals from photoplethysmography
    Casal, Ramiro
    Schlotthauer, Gaston
    2017 XVII WORKSHOP ON INFORMATION PROCESSING AND CONTROL (RPIC), 2017,
  • [14] Blood Pressure Level and Heart Rate Detection from Photoplethysmography Signals Using DT-CWT
    Koklukaya, Fatma Sevde
    Ozturk, Mahmut
    2022 30TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU, 2022,
  • [15] Real Time Heart Rate Detection Using Non-Contact Photoplethysmography Signals
    Kavsaoglu, Ahmet Resit
    Polat, Kemal
    Bozkurt, Mehmet Recep
    2014 22ND SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2014, : 196 - 199
  • [16] Probability of detection of clinical seizures using heart rate changes
    Osorio, Ivan
    Manly, B. F. J.
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2015, 30 : 120 - 123
  • [17] Contactless assessment of heart rate in neonates within a clinical environment using imaging photoplethysmography
    Svoboda, Libor
    Sperrhake, Jan
    Nisser, Maria
    Taphorn, Luca
    Proquitte, Hans
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [18] Fingertip Based Estimation Of Heart Rate Using Photoplethysmography
    Aarthi, Yamuna
    Karthikeyan, B.
    Raj, N. Prithivi
    Ganesan, M.
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING & COMMUNICATION SYSTEMS (ICACCS), 2019, : 817 - 821
  • [19] Heart Rate Variability Using Photoplethysmography with Green Wavelength
    Ruiz, Luis M.
    Manzo, Alain
    Casimiro, Edgar
    Cardenas, Edgar
    Gonzalez, Rodolfo
    2014 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2014,
  • [20] A Comparison of Reflective Photoplethysmography for Detection of Heart Rate, Blood Oxygen Saturation, and Respiration Rate at Various Anatomical Locations
    Longmore, Sally K.
    Lui, Gough Y.
    Naik, Ganesh
    Breen, Paul P.
    Jalaludin, Bin
    Gargiulo, Gaetano D.
    SENSORS, 2019, 19 (08):