Secondary cancer-incidence risk estimates for external radiotherapy and high-dose-rate brachytherapy in cervical cancer: phantom study

被引:0
|
作者
Lee, Boram [1 ,2 ]
Ahn, Sung Hwan [2 ]
Kim, Hyeyoung [2 ]
Son, Jaeman [1 ]
Sung, Jiwon [1 ]
Han, Youngyih [3 ]
Huh, Seung Jae [3 ]
Kim, Jin Sung [4 ]
Kim, Dong Wook [5 ]
Yoon, Myonggeun [1 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, 145 AnamRo, Seoul 02841, South Korea
[2] Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiat Oncol, Seoul, South Korea
[4] Yonsei Canc Ctr, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[5] Kyung Hee Univ Hosp Gangdong, Dept Radiat Oncol, Seoul, South Korea
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 05期
基金
新加坡国家研究基金会;
关键词
secondary cancer risk; brachytherapy; cervical cancer; lifetime attributable risks; IMAGE-GUIDED BRACHYTHERAPY; SQUAMOUS-CELL CARCINOMA; UTERINE CERVIX; 2ND CANCER; PRIMARY MALIGNANCY; PROGNOSTIC-FACTORS; NATIONAL PRACTICE; GLASS DOSIMETER; PATTERNS; BEAM;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to estimate radiation-induced secondary cancer risks from high-dose-rate (HDR) brachytherapy and external radiotherapy for patients with cervical cancer based on measurements of doses absorbed by various organs. Organ doses from HDR brachytherapy and external radiotherapy were measured using glass rod dosimeters. Doses to out-of-field organs were measured at various locations inside an anthropomorphic phantom. Brachytherapy-associated organ doses were measured using a specialized phantom that enabled applicator insertion, with the pelvis portion of the existing anthropomorphic phantom replaced by this new phantom. Measured organ doses were used to calculate secondary cancer risk based on Biological Effects of Ionizing Radiation (BEIR) VII models. In both treatment modalities, organ doses per prescribed dose (PD) mostly depended on the distance between organs. The locations showing the highest and lowest doses were the right kidney (external radiotherapy: 215.2 mGy; brachytherapy: 655.17 mGy) and the brain (external radiotherapy: 15.82 mGy; brachytherapy: 2.49 mGy), respectively. Organ doses to nearby regions were higher for brachytherapy than for external beam therapy, whereas organ doses to distant regions were higher for external beam therapy. Organ doses to distant treatment regions in external radiotherapy were due primarily to out-of-field radiation resulting from scattering and leakage in the gantry head. For brachytherapy, the highest estimated lifetime attributable risk per 100,000 population was to the stomach (88.6), whereas the lowest risks were to the brain (0.4) and eye (0.4); for external radiotherapy, the highest and lowest risks were to the thyroid (305.1) and brain (2.4). These results may help provide a database on the impact of radiotherapy-induced secondary cancer incidence during cervical cancer treatment, as well as suggest further research on strategies to counteract the risks of radiotherapy-associated secondary malignancies.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 50 条
  • [41] CONE BEAM CT-BASED THREE-DIMENSIONAL PLANNING IN HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL CANCER
    Al-Halabi, Hani
    Portelance, Lorraine
    Duclos, Marie
    Reniers, Brigitte
    Bahoric, Boris
    Souhami, Luis
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1092 - 1097
  • [42] Out-of-field dose measurement and second cancer-risk estimation following external beam radiotherapy and brachytherapy for cervical cancer treatment: A phantom study
    Hemalatha A.
    Mayilvaganan A.
    Joan M.
    Chougule A.
    Kumar H.S.
    Iranian Journal of Medical Physics, 2020, 17 (04) : 253 - 259
  • [43] Outcomes from a 3-fraction high-dose-rate brachytherapy regimen for patients with cervical cancer
    Williamson, Casey W.
    Kotha, Nikhil V.
    Zou, Jingjing
    Brown, Derek
    Scanderbeg, Daniel
    Rash, Dominique
    Einck, John
    Yashar, Catheryn
    Mell, Loren K.
    Mayadev, Jyoti
    BRACHYTHERAPY, 2023, 22 (03) : 317 - 324
  • [44] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [45] Low-dose-rate, high-dose-rate, and pulsed-dose-rate intra-cavitary brachytherapy for cervical cancer: The very first comparison study
    Sharma, Daya Nand
    Kumar, Pavnesh
    Subramani, Vellaiyan
    Giridhar, Prashanth
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2024, 16 (04) : 273 - 278
  • [46] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [47] Under-utilisation of high-dose-rate brachytherapy boost in men with intermediate-high risk prostate cancer treated with external beam radiotherapy
    Ong, Wee Loon
    Evans, Sue M.
    Millar, Jeremy L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (02) : 256 - 261
  • [48] Implant time and process efficiency for CT-guided high-dose-rate brachytherapy for cervical cancer
    Mayadev, Jyoti
    Qi, Lihong
    Lentz, Susan
    Benedict, Stanley
    Courquin, Jean
    Dieterich, Sonja
    Mathai, Mathew
    Stern, Robin
    Valicenti, Richard
    BRACHYTHERAPY, 2014, 13 (03) : 233 - 239
  • [49] Association of bladder dose with late urinary side effects in cervical cancer high-dose-rate brachytherapy
    Zakariaee, Roja
    Hamarneh, Ghassan
    Brown, Colin J.
    Gaudet, Marc
    Aquino-Parsons, Christina
    Spadinger, Ingrid
    BRACHYTHERAPY, 2017, 16 (06) : 1175 - 1183
  • [50] The impact of body mass index on rectal dose in locally advanced cervical cancer treated with high-dose-rate brachytherapy
    Lim, Jihoon
    Durbin-Johnson, Blythe
    Valicenti, Richard
    Mathai, Matthew
    Stem, Robin L.
    Mayadev, Jyoti
    BRACHYTHERAPY, 2013, 12 (06) : 550 - 554