Measuring free-living energy expenditure and physical activity with triaxial accelerometry

被引:116
作者
Plasqui, G
Joosen, AMCP
Kester, AD
Goris, AHC
Westerterp, K
机构
[1] Univ Limburg, Dept Human Biol, NL-6200 MD Maastricht, Netherlands
[2] Univ Limburg, Dept Methodol & Stat, NL-6200 MD Maastricht, Netherlands
来源
OBESITY RESEARCH | 2005年 / 13卷 / 08期
关键词
doubly labeled water; sleeping metabolic rate; body composition; activity counts; uniaxiall vs. triaxial;
D O I
10.1038/oby.2005.165
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate the ability of a newly developed triaxial accelerometer to predict total energy expenditure (EE) (TEE) and activity-related EE (AEE) in free-living conditions. Research Methods and Procedures: Subjects were 29 healthy subjects between the ages of 18 and 40. The Triaxial Accelerometer for Movement Registration (Tracmor) was worn for 15 consecutive days. Tracmor output was defined as activity counts per day (ACD) for the sum of all three axes or each axis separately (ACD-X, ACD-Y, ACD-Z). TEE was measured with the doubly labeled water technique. Sleeping metabolic rate (SMR) was measured during an overnight stay in a respiration chamber. The physical activity level was calculated as TEE X SMR-1, and AEE was calculated as [(0.9 X TEE) - SMR]. Body composition was calculated from body weight, body volume, and total body water using Siri's three-compartment model. Results: Age, height, body mass, and ACD explained 83% of the variation in TEE [standard error of estimate (SEE) = 1.00 MJ/d] and 81% of the variation in AEE (SEE = 0.70 MJ/d). The partial correlations for ACD were 0.73 (p < 0.001) and 0.79 (p < 0.001) with TEE and AEE, respectively. When data on SMR or body composition were used with ACD, the explained variation in TEE was 90% (SEE = 0.74 and 0.77 MJ/d, respectively). The increase in the explained variation using three axes instead of one axis (vertical) was 5% (p < 0.05). Discussion: The correlations between Tracmor output and EE measures are the highest reported so far. To measure daily life activities, the use of triaxial accelerometry seems beneficial to uniaxial.
引用
收藏
页码:1363 / 1369
页数:7
相关论文
共 31 条
[1]  
Ayen TG, 1988, J AMBULATORY MONIT, V1, P293
[2]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[3]   Daily physical activity assessment: Comparison between movement registration and doubly labeled water [J].
Bouten, CVC ;
VerboeketVandeVenne, WPHG ;
Westerterp, KR ;
Verduin, M ;
Janssen, JD .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (02) :1019-1026
[4]  
Chan KM, 2003, B WORLD HEALTH ORGAN, V81, P827
[5]  
Ekelund U, 2004, AM J CLIN NUTR, V79, P851
[6]  
Ekelund U, 2001, MED SCI SPORT EXER, V33, P275
[7]   Exercise, body mass index, caloric intake, and cardiovascular mortality [J].
Fang, J ;
Wylie-Rosett, J ;
Cohen, HW ;
Kaplan, RC ;
Alderman, MH .
AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2003, 25 (04) :283-289
[8]  
Goris AHC, 2001, AM J CLIN NUTR, V73, P549
[9]   Physical activity level measured by doubly labeled water and accelerometry in children [J].
Hoos, MB ;
Plasqui, G ;
Gerver, WJM ;
Westerterp, KR .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 89 (06) :624-626
[10]   Television watching and other sedentary behaviors in relation to risk of obesity and type 2 diabetes mellitus in women [J].
Hu, FB ;
Li, TY ;
Colditz, GA ;
Willett, WC ;
Manson, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (14) :1785-1791