High-Pressure Total Internal Reflection Fluorescence Apparatus

被引:2
|
作者
Dabney, Michael J. [1 ]
Bright, Frank V. [1 ]
机构
[1] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
关键词
High pressure; Total internal reflection fluorescence; Picosecond; Interfacial dynamics; Interfacial microviscosities; Supercritical carbon dioxide; ACRIDINE-ORANGE; REORIENTATION; DYNAMICS; WATER; MONOLAYER; SPECTROSCOPY; BODIPY;
D O I
10.1366/11-06399
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Important interfacial processes in disciplines ranging from medicine to the separations sciences occur over a wide range of pressures, temperatures, and time scales. In this paper we report a new high-pressure total internal reflection fluorescence (HP-TIRF) apparatus that allows rapid fluorescence measurements of sub-monolayers in contact with liquids and supercritical fluids between 293 K and 353 K and up to 250 bar with picosecond time resolution. We use the HP-TIRF system to study the in-plane rotational reorientation dynamics of the fluorescent probe BODIPY 494/503 (C-2v, symmetry) covalently attached to silica surfaces that have been silanized with n-propyltrimethoxysilane (C-3-TMOS) or 3,3,3-trifluoropropyltrimethoxysilane (CF3-TMOS) when the interface is subjected to pure supercritical carbon dioxide (scCO(2)). The in-plane BODIPY 494/503 rotational reorientation dynamics are assessed by using the Debye-Stokes-Einstein expression. As the scCO(2) density increases the local microviscosity surrounding the tethered BODIPY 494/503 molecule decreases. The terminal group (CH3 versus CF3) within the silane monolayer governs the onset and absolute magnitude of the observed viscosity changes. The results are explained in terms of the well-known solubility of fluorine-containing species in scCO(2).
引用
收藏
页码:1233 / 1239
页数:7
相关论文
共 50 条
  • [21] Single-molecule fluorescence imaging by total internal reflection fluorescence microscopy (IUPAC Technical Report)
    Knight, Alex E.
    PURE AND APPLIED CHEMISTRY, 2014, 86 (08) : 1303 - 1320
  • [22] High-Throughput Total Internal Reflection Fluorescence and Direct Stochastic Optical Reconstruction Microscopy Using a Photonic Chip
    Coucheron, David Andre
    Helle, Oystein Ivar
    Oie, Cristina Ionica
    Tinguely, Jean-Claude
    Ahluwalia, Balpreet Singh
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (153):
  • [23] Development and testing of a new apparatus for the measurement of high-pressure low-temperature phase equilibria
    Fonseca, Jose M. S.
    von Solms, Nicolas
    FLUID PHASE EQUILIBRIA, 2012, 329 : 55 - 62
  • [24] A sieverts apparatus for measuring high-pressure hydrogen isotherms on porous materials
    Pyle, D. S.
    Webb, C. J.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (31) : 20111 - 20119
  • [25] Single molecule imaging of BK channels using total internal reflection fluorescence microscopy
    Ikeda, Chikako
    Yamamura, Hisao
    Ohya, Susumu
    Imaizumi, Yuji
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2007, 127 : 169 - 172
  • [27] Plasmonically amplified bioassay - Total internal reflection fluorescence vs. epifluorescence geometry
    Hageneder, Simone
    Bauch, Martin
    Dostalek, Jakub
    TALANTA, 2016, 156 : 225 - 231
  • [28] A spectrometric setup for synchronous total internal reflection fluorescence measurement at the solid/liquid interface
    Li, YQ
    Xu, JJ
    Wang, RT
    Yu, LJ
    Li, Z
    CHINESE CHEMICAL LETTERS, 2002, 13 (06) : 571 - 572
  • [29] A label-free continuous total-internal-reflection-fluorescence-based immunosensor
    Engstrom, Henrik A.
    Andersson, Per Ola
    Ohlson, Sten
    ANALYTICAL BIOCHEMISTRY, 2006, 357 (02) : 159 - 166
  • [30] Biosensors on Array Chip by Dual-color Total Internal Reflection Fluorescence Microscopy
    Kang, Seong Ho
    Islam, Md. Shahinul
    BIOCHIP JOURNAL, 2009, 3 (02) : 97 - 104