Polyaxial locking plates in treating distal humeral fractures: a comparative randomized trial for clinical outcome

被引:4
作者
Croenlein, Moritz [1 ]
Lucke, Martin [3 ]
Beirer, Marc [1 ]
Pfoerringer, Dominik [1 ]
Kirchhoff, Chlodwig [1 ]
Biberthaler, Peter [1 ]
Braun, Karl F. [1 ]
Siebenlist, Sebastian [1 ,2 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Trauma Surg, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthopaed Sports Med, Ismaninger Str 22, D-81675 Munich, Germany
[3] Chirurg Klinikum Munchen Sud, Dept Trauma Surg, Isarkanal 30, D-81379 Munich, Germany
来源
BMC MUSCULOSKELETAL DISORDERS | 2017年 / 18卷
关键词
Distal humeral fracture; Locking plate; Anatomical preshaped; Polyaxial; Outcome; INTRAARTICULAR FRACTURES; FEMUR FRACTURES; FIXATION; CONFIGURATION; STABILITY; SYSTEMS; SCREWS;
D O I
10.1186/s12891-017-1910-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Management of distal humeral fractures remains to be one of the most challenging aspects in trauma surgery. Low profile plating systems with variable angle screw fixation represent a crucial advancement to the established angular stable locking plates with considerable attention in current research. The aim of the prospective randomized trial was to review the preliminary results and patients' outcome following treatment with these newly developed implants and to rule out potential differences in fracture treatment of two different plating systems. Methods: Twenty patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes (R) VA-LCP vs. Medartis (R) Aptus Elbow). Functional elbow scoring (ROM, MEPS, QuickDASH) served as primary outcome parameter, while radiological fracture consolidation served as secondary outcome parameter. Follow-ups were conducted 6 weeks, 12 weeks, 6 months and 12 months after the operation. Results: Seventeen of 20 patients (85%) concluded all follow-up examinations. Postoperative elbow extension deficiencies showed significant differences between the two groups in all follow-up examinations with a mean of (sic) 18 +/- 7.4 degrees in the DePuy Synthes (R) VA-LCP group compared to a mean of (sic) 6.5 +/- 7.5 degrees in the Medartis (R) Aptus Elbow group (p = 0.002) 12 months postoperatively. Functional scoring showed a disparate pattern. The Medartis (R) Aptus Elbow group achieved significantly better MEP scores during follow-up. However, the analysis of the QuickDash revealed better results of the DePuy Synthes (R) VA-LCP group in the first half and better results of the Medartis (R) Aptus Elbow group in the second half of the follow-up examination instead. Conclusions: Considering the complexity of distal humeral fractures, the usage of anatomically preshaped low profile variable angle locking plates for operative treatment leads to good clinical results. Even though there might be some advances of the Medartis (R) Aptus Elbow plating system concerning postoperative ROM and elbow function, a consistent difference in the overall clinical outcome between the two plating systems could not be detected.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Fixation of periprosthetic or osteoporotic distal femoral fractures with locking plates: a pilot randomised controlled trial
    Nikolaos K. Kanakaris
    Oghofori Obakponovwe
    Matija Krkovic
    Matt L. Costa
    David Shaw
    Khitish R. Mohanty
    Robert M. West
    Peter V. Giannoudis
    [J]. International Orthopaedics, 2019, 43 : 1193 - 1204
  • [42] Comparison of locking plates and intramedullary nails in treatment of three-part or four-part proximal humeral neck fractures in elderly population A randomized trial protocol
    Song, Hua
    Wang, Mingming
    Du, Hongyang
    Mu, Weidong
    [J]. MEDICINE, 2020, 99 (46) : E22914
  • [43] Locking plates for distal fibula fractures in young and elderly patients: A retrospective study
    Evola, Francesco Roberto
    Di Fede, Giovanni Francesco
    Evola, Giuseppe
    Barchitta, Martina
    Agodi, Antonella
    Longo, Gianfranco
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2023, 14 (07): : 540 - 546
  • [44] Biomechanical Comparative Analyses Between the Anterolateral and Medial Distal Tibia Locking Plates in Treating Complex Distal Tibial Fracture: A Finite Element Study
    Aizat, Raja Mohd
    Kadir, Mohammed Rafiq Abdul
    Ab Rahman, Shaifuzain
    Shihabudin, Tengku Muzaffar Tengku Md
    Robson, Noorzurani
    Kamarul, Tunku
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 532 - 537
  • [45] Early Clinical Outcomes of Polyaxial Locking Cap Plate Fixation for Fixation of Displaced Olecranon Fractures
    Gutman, Michael Jason
    Patel, Manan Sunil
    Connelly, James William
    Paxton, Edward Scott
    Namdari, Surena
    Horneff, John Gabriel
    [J]. ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2025, 13 (01): : 23 - 29
  • [46] Locking Plates for Distal Femur Fractures: Is There a Problem With Fracture Healing?
    Henderson, Christopher E.
    Kuhl, Lori L.
    Fitzpatrick, Daniel C.
    Marsh, J. L.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 : S8 - S14
  • [47] Comparison of Locking Versus Nonlocking Plates for Distal Fibula Fractures
    Lyle, Shirley A.
    Malik, Catherine
    Oddy, Michael J.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (04) : 664 - 667
  • [48] Locking versus non-locking neutralization plates for treatment of lateral malleolar fractures: a randomized controlled trial
    Tsukada, Sachiyuki
    Otsuji, Masaki
    Shiozaki, Akira
    Yamamoto, Asako
    Komatsu, Shuro
    Yoshimura, Hideya
    Ikeda, Hiroo
    Hoshino, Akiho
    [J]. INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2451 - 2456
  • [49] The feasibility and results of an arthroscopic removal of humeral locking plates and glenohumeral arthrolysis after proximal humeral fractures
    Maqdes, Ali
    Levy, Bruno
    Klouche, Shahnaz
    Hardy, Philippe
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (02) : 456 - 461
  • [50] Extended Use of Proximal Humeral Locking Plates in Pediatric Femur Fractures and Osteotomies
    Singh, Sanjeev Kumar
    Agrawal, Tushar
    Jain, Deepak
    Velankar, Ameya
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2024, 39 (03) : 81 - 85