ALARA: is there a cause for alarm? Reducing radiation risks from computed tomography scanning in children
被引:155
作者:
Shah, Nikhil Bharat
论文数: 0引用数: 0
h-index: 0
机构:
New York Presbyterian Hosp, Weill Cornell Med Ctr, Div Pediat Emergency Med, Dept Emergency Med, New York, NY 10021 USANew York Presbyterian Hosp, Weill Cornell Med Ctr, Div Pediat Emergency Med, Dept Emergency Med, New York, NY 10021 USA
Shah, Nikhil Bharat
[1
]
Platt, Shari L.
论文数: 0引用数: 0
h-index: 0
机构:
New York Presbyterian Hosp, Weill Cornell Med Ctr, Div Pediat Emergency Med, Dept Emergency Med, New York, NY 10021 USANew York Presbyterian Hosp, Weill Cornell Med Ctr, Div Pediat Emergency Med, Dept Emergency Med, New York, NY 10021 USA
Platt, Shari L.
[1
]
机构:
[1] New York Presbyterian Hosp, Weill Cornell Med Ctr, Div Pediat Emergency Med, Dept Emergency Med, New York, NY 10021 USA
ALARA;
as low as reasonably achievable;
children;
computed tomography;
radiation;
safety;
D O I:
10.1097/MOP.0b013e3282ffafd2
中图分类号:
R72 [儿科学];
学科分类号:
100202 ;
摘要:
Purpose of review Radiation exposure from computed tomography is associated with a small but significant increase in risk for fatal cancer over a child's lifetime. This review aims to heighten awareness and spearhead efforts to reduce unnecessary computed tomography scans in children. Recent findings The use of pediatric computed tomography continues to grow despite evidence on known risks of computed tomography-related radiation and induction of fatal cancers in children. More than 60 million computed tomography scans are estimated to be performed annually in the USA, with 7 million in children. Pediatric radiologists apply the practice of ALARA ('as low as reasonably achievable') to reduce radiation exposure. Education and advocacy directed to the referring clinician reinforce these principles. Radiation exposure may be further reduced by developing clinical pathways limiting computed tomography scanning and encourage alternate, nonradiation imaging modalities, such as ultrasound and magnetic resonance imaging. Although individual risk estimates are small, widespread use of computed tomography in the population may implicate a future public health issue. Summary Advocacy by pediatric healthcare providers to promote intelligent dose reduction based on the principles of ALARA and the judicious use of computed tomography scanning is essential to foster the safest possible care of children.
引用
收藏
页码:243 / 247
页数:5
相关论文
共 32 条
[1]
[Anonymous], Radiation risks and pediatric computed tomography
机构:
Duke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Coursey, Courtney
;
Frush, Donald P.
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Frush, Donald P.
;
Yoshizumi, Terry
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Yoshizumi, Terry
;
Toncheva, Greta
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Toncheva, Greta
;
Nguyen, Giao
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Nguyen, Giao
;
Greenberg, S. Bruce
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arkansas Med Sci, Dept Radiol, Little Rock, AR 72205 USA
Arkansas Childrens Hosp, Little Rock, AR 72202 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
机构:
Duke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Coursey, Courtney
;
Frush, Donald P.
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Frush, Donald P.
;
Yoshizumi, Terry
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Yoshizumi, Terry
;
Toncheva, Greta
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Toncheva, Greta
;
Nguyen, Giao
论文数: 0引用数: 0
h-index: 0
机构:
Duke Univ, Med Ctr, Radiat Safety Div, Durham, NC 27710 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA
Nguyen, Giao
;
Greenberg, S. Bruce
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arkansas Med Sci, Dept Radiol, Little Rock, AR 72205 USA
Arkansas Childrens Hosp, Little Rock, AR 72202 USADuke Univ, Med Ctr, Dept Radiol, Div Pediat Radiol, Durham, NC 27710 USA