Customized data center cooling system operating at significant outdoor temperature fluctuations

被引:18
作者
Borkowski, Mateusz [1 ]
Pilat, Adam Krzysztof [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Elect Engn Automat Comp Sci & Biomed Engn, Dept Automat Control & Robot, Al Mickiewicza 30, PL-30059 Krakow, Poland
关键词
Data center; Chiller; Freecooling; COP; Compressor mode; Experimental data; ENERGY-EFFICIENT; SIMULATION; MANAGEMENT; DESIGN;
D O I
10.1016/j.apenergy.2021.117975
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This elaboration presents the configuration of the cooling system of the POLCOM Data Center which utilizes commercially available components, proposes steering strategy and analyzes their functionality. The designed architecture of cooling and dedicated control system is presented to demonstrate the novelty and customization with respect to the demanding outdoor temperatures existing in the climate of the Malopolska Province. The cooling system control and operation is illustrated by a comprehensive analysis of compressor and freecooling modes. The discussion on embedded functionality of chillers is undertaken. According to features and limitations of the complex solution, the cooling system reached the annual average coefficient of performance of 8.63 in 2015 (increase of 110% compared to the year 2014), operating 65% of the time during the year in compressor mode and 35% in freecooling mode. This coefficient in compressor mode amounted to 4.39 while in freecooling mode totaled 16.50. It was proved that in the real case under consideration they generated losses in electricity consumption amounting to 557MWh per year. The real-time experimental data collected from the commercial Data Center installation are used to present a unique operation of a such complex system.
引用
收藏
页数:11
相关论文
共 31 条
[1]   Free cooling potential for Brazilian data centers based on approach point methodology [J].
Amado, E. A. ;
Schneider, P. S. ;
Bresolin, C. S. .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 122 :171-180
[2]   Exploitation and optimal management of free cooling for industrial refrigeration [J].
Canova, Aldo ;
Laudicina, Giuseppe ;
Lazzeroni, Paolo ;
Perez-Mora, Nicolas ;
Repetto, Maurizio .
ENERGY CONVERSION AND MANAGEMENT, 2019, 198
[3]   Cooling systems in data centers: state of art and emerging technologies [J].
Capozzoli, Alfonso ;
Primiceri, Giulio .
SUSTAINABILITY IN ENERGY AND BUILDINGS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE SEB-15, 2015, 83 :484-493
[4]   Experimental and numerical analysis for potential heat reuse in liquid cooled data centres [J].
Carbo, Andreu ;
Oro, Eduard ;
Salom, Jaume ;
Canuto, Mauro ;
Macias, Mario ;
Guitart, Jordi .
ENERGY CONVERSION AND MANAGEMENT, 2016, 112 :135-145
[5]  
Castellazzi L., 2017, TRENDS DATA CTR ENER, DOI [10.2760/358256, DOI 10.2760/358256]
[6]   Optimal design of data center cooling systems concerning multi-chiller system configuration and component selection for energy-efficient operation and maximized free-cooling [J].
Cheung, Howard ;
Wang, Shengwei .
RENEWABLE ENERGY, 2019, 143 :1717-1731
[7]   Development and experimental study of an independent row-based cooling system for improving thermal performance of a data center [J].
Cho, Jinkyun ;
Woo, Jesang .
APPLIED THERMAL ENGINEERING, 2020, 169
[8]   Improving energy efficiency of dedicated cooling system and its contribution towards meeting an energy-optimized data center [J].
Cho, Jinkyun ;
Kim, Yundeok .
APPLIED ENERGY, 2016, 165 :967-982
[9]   Development of an energy evaluation and design tool for dedicated cooling systems of data centers: Sensing data center cooling energy efficiency [J].
Cho, Jinkyun ;
Yang, Joonyoung ;
Lee, Changkeun ;
Lee, Jinyoung .
ENERGY AND BUILDINGS, 2015, 96 :357-372
[10]   Economic analysis of data center cooling strategies [J].
Cho, Kyuman ;
Chang, Hyunjae ;
Jung, Yongho ;
Yoon, Yoojung .
SUSTAINABLE CITIES AND SOCIETY, 2017, 31 :234-243