Chiral capillary electrophoresis mass spectrometry of tetrahydroisoquinoline-derived neurotoxins: Observation of complex stereoisomerism

被引:28
|
作者
Wu, Hao [1 ]
Yuan, Baiqing [1 ]
Liu, Yi-Ming [1 ]
机构
[1] Jackson State Univ, Dept Chem & Biochem, Jackson, MS 39110 USA
基金
美国国家卫生研究院;
关键词
Chiral capillary electrophoresis; Mass spectrometry; Neurotoxin; Tetrahydroisoquinoline; N-methylsalsolinol; Stereoisomer; ENDOGENOUS DOPAMINERGIC NEUROTOXIN; PERFORMANCE LIQUID-CHROMATOGRAPHY; SALSOLINOL ENANTIOMERS; BETA-CYCLODEXTRIN; PARKINSONS-DISEASE; BIOLOGICAL SAMPLES; R-SALSOLINOL; S-SALSOLINOL; HUMAN PLASMA; AMINO-ACIDS;
D O I
10.1016/j.chroma.2011.03.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Previous studies have shown that certain 1,2,3,4-tetrahydroisoquinoline derivatives (TIQs) are neurotoxins inducing Parkinsonism. Further, individual enantiomers of these toxins such as (RIS)-N-methylsalsolinol ((R/S)-NMSal) possess distinct neurotoxicological properties. In this work, a chiral capillary electrophoresis (CE) method with electrospray ionization-tandem mass spectrometric (ESI-MS/MS) detection was developed for the quantification of TIQ enantiomers. Enantioseparation was achieved with sulfated beta-cyclodextrin (sulfated beta-CD) as chiral selector. To avoid any potential contamination of MS ionization source by the non-volatile chiral selector, partial filling technique was deployed in the CE separation. TIQ derivatives, including (R/S)-6,7-dihydroxy-1-methy-TIQ (salsolinol, Sal), (RIS)1-benzyl-TIQ (BTIQ), and (R/S)-NMSal, were base-line resolved with resolution values (R) ranging from 3 (for Sal) to 4.5 (for BTIQ), which were much better than those reported previously by HPLC methods. ESI-MS/MS detection of the resolved TIQ enantiomers was specific and sensitive CLOD = 1.2 mu M for Sal enantiomers). The proposed chiral CE-MS/MS method was used to study in vitro formation of (RIS)NMSal. It was found that NMSal was formed from the incubation of epinine (a dopamine metabolite) with acetaldehyde (a metabolite of alcohol). More interestingly, four isomers of NMSal were separated and detected in the incubation solution. They were identified as (R)-e.e-NMSal, (R)-e.a-NMSal, (S)-e.e-NMSal, and (S)-e.a-NMSal. This was the first lab evidence that this Parkinsonian neurotoxin exists in multiple isomeric forms. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3118 / 3123
页数:6
相关论文
共 50 条
  • [41] Sample treatments prior to capillary electrophoresis-mass spectrometry
    Hernandez-Borges, Javier
    Borges-Miquel, Teresa M.
    Rodriguez-Delgado, Miguel Angel
    Cifuentes, Alejandro
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1153 (1-2) : 214 - 226
  • [42] Ambient laser ablation sampling for capillary electrophoresis mass spectrometry
    Park, Sung-Gun
    Murray, Kermit K.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (15) : 1673 - 1680
  • [43] Capillary zone electrophoresis electrospray mass spectrometry of priority phenols
    Tsai, CY
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (02) : 315 - 321
  • [44] Quantitative metabolome analysis using capillary electrophoresis mass spectrometry
    Soga, T
    Ohashi, Y
    Ueno, Y
    Naraoka, H
    Tomita, M
    Nishioka, T
    JOURNAL OF PROTEOME RESEARCH, 2003, 2 (05) : 488 - 494
  • [45] Recent advances in capillary electrophoresis/electrospray-mass spectrometry
    von Brocke, A
    Nicholson, G
    Bayer, E
    ELECTROPHORESIS, 2001, 22 (07) : 1251 - 1266
  • [46] Advances in capillary electrophoresis-mass spectrometry for cell analysis
    Zhou, Wei
    Zhang, Baofang
    Liu, Yikun
    Wang, Chenlu
    Sun, Wenqi
    Li, Wen
    Chen, Zilin
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 117 (316-330) : 316 - 330
  • [47] Capillary electrophoresis with Orbitrap-Velos mass spectrometry detection
    Wojcik, Roza
    Li, Yihan
    MacCoss, Michael J.
    Dovichi, Norman J.
    TALANTA, 2012, 88 : 324 - 329
  • [48] Arsenic speciation by coupling capillary zone electrophoresis with mass spectrometry
    L. Debusschere
    C. Demesmay
    J. L. Rocca
    Chromatographia, 2000, 51 : 262 - 268
  • [49] Metabolome analysis based on capillary electrophoresis-mass spectrometry
    Hirayama, Akiyoshi
    Wakayama, Masataka
    Soga, Tomoyoshi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 61 : 215 - 222
  • [50] Development of a lipoprotein profile using capillary electrophoresis and mass spectrometry
    Macfarlane, RD
    Bondarenko, PV
    Cockrill, SL
    Cruzado, ID
    Koss, W
    McNeal, CJ
    Spiekerman, AM
    Watkins, LK
    ELECTROPHORESIS, 1997, 18 (10) : 1796 - 1806