Potency estimation of recombinant factor VIII: effect of assay method and standard

被引:28
作者
Hubbard, AR [1 ]
Bevan, SA [1 ]
Weller, LJ [1 ]
机构
[1] Natl Inst Biol Stand & Controls, Div Haematol, Potters Bar EN6 3QG, Herts, England
关键词
haemophilia A; factor VIII; reference standards;
D O I
10.1046/j.1365-2141.2001.02761.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Large potency discrepancies between the chromogenic and one-stage clotting methods have been reported for patients' plasma samples following the infusion of recombinant factor VIII (rFVIII) concentrates. We have investigated the potency estimation of two different full-length rFVIII concentrates using both assay methods relative to both plasma and concentrate standards. Potencies by the chromogenic method were significantly higher (53% and 45%) than potencies by the one-stage clotting method when a plasma standard was used. In contrast, there was no significant potency difference between methods when a concentrate standard was used, Time-course studies into thrombin and activated factor X (FXa) generation, in modified clotting and chromogenic methods, respectively, revealed that the two rFVIII concentrates behaved very similarly to the concentrate standard, whereas the plasma standard showed slightly more rapid thrombin generation and markedly slower FXa generation. The different behaviour of rFVIII and plasma FVIII in the chromogenic method is proposed as the main cause of the methods-based potency discrepancy. The results support the use of a concentrate standard to measure rFVIII in post-infusion plasma.
引用
收藏
页码:533 / 536
页数:4
相关论文
共 10 条
  • [1] BARROWCLIFFE TW, 1993, THROMB HAEMOSTASIS, V70, P876
  • [2] Discrepancies in potency assessment of recombinant FVIII concentrates
    Barrowcliffe, TW
    Raut, S
    Hubbard, AR
    [J]. HAEMOPHILIA, 1998, 4 (04) : 634 - 640
  • [3] INTERNATIONAL BIOLOGICAL STANDARDS AND REFERENCE PREPARATIONS .1. PREPARATION AND PRESENTATION OF MATERIALS TO SERVE AS STANDARDS AND REFERENCE PREPARATIONS
    CAMPBELL, PJ
    [J]. JOURNAL OF BIOLOGICAL STANDARDIZATION, 1974, 2 (04): : 249 - 258
  • [4] Colvin BT, 1997, HAEMOPHILIA, V3, P63, DOI 10.1046/j.1365-2516.1997.00073.x
  • [5] DISCREPANCY BETWEEN ONE-STAGE AND 2-STAGE ASSAY OF FACTOR-VIII-C
    KIRKWOOD, TBL
    BARROWCLIFFE, TW
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1978, 40 (02) : 333 - 338
  • [6] Lee C, 1996, THROMB HAEMOSTASIS, V76, P950
  • [7] Lee CA, 1999, THROMB HAEMOSTASIS, V82, P1644
  • [8] In vivo recovery with products of very high purity - assay discrepancies
    Lusher, JM
    Hillman-Wiseman, C
    Hurst, D
    [J]. HAEMOPHILIA, 1998, 4 (04) : 641 - 645
  • [9] LUSHER JM, 1996, HAEMOPHILIA S1, V2, P53
  • [10] Influence of phospholipids on the assessment of factor VIII activity
    Mikaelsson, M
    Oswaldsson, U
    Sandberg, H
    [J]. HAEMOPHILIA, 1998, 4 (04) : 646 - 650