Rapid FRET-based homogeneous immunoassay of procalcitonin using matched carbon dots labels

被引:2
作者
Liu, Bo [1 ]
Yang, Kun [1 ]
Lu, Siyu [1 ]
Cai, Junjie [1 ,2 ]
Li, Fan [1 ]
Tian, Feng [1 ]
机构
[1] Acad Mil Med Sci, Inst Med Support Technol, Tianjin 300161, Peoples R China
[2] Bethune Int Peace Hosp, Shijiazhuang 050000, Hebei, Peoples R China
关键词
CDs; procalcitonin; immunoprobe; homogeneous immunoassay; QUANTUM DOTS; SEPSIS; STABILITY; EDC/NHS;
D O I
10.1088/1361-6528/ac3aab
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel method for the detection of procalcitonin in a homogeneous system by matched carbon dots (CDs) labeled immunoprobes was proposed based on the principle of FRET and double antibody sandwich method. Blue-emitting carbon dots with a strong fluorescence emission range of 400-550 nm and red-emitting carbon dots with the best excitation range of 410-550 nm were prepared before they reacted with procalcitonin protoclone antibody pairs to form immunoprobes. According to the principles of FRET, blue-emitting carbon dots were selected as the energy donor and red-emitting carbon dots as the energy receptor. The external light source excitation (310 nm) could only cause weak luminescence of CDs. However, once procalcitonin was added, procalcitonin and antibodies would be combined with each other quickly (<= 20 min). Here, blue-emitting carbon dots acquired energy could be transferred to red-emitting carbon dots efficiently, causing the emitted fluorescence enhancement of red-emitting carbon dots. The fluorescence detection results in PBS buffer solution and diluted rabbit blood serum showed that the fluorescence intensity variation was linear with the concentration of procalcitonin. There was a good linear relationship between F/F0 and procalcitonin concentrations in PBS buffer solution that ranged from 0 to 100 ng ml(-1), and the linear equation was F/F0 = 0.004 * C (pct) + 0.98359. Detection in the diluted rabbit serum led to the results that were linear in two concentration ranges, including 0-40 ng ml(-1) and 40-100 ng ml(-1), and the detection limit based on 3 sigma K-1 was 0.52 ng ml(-1). It is likely that this matched CDs labeled immunoprobes system can provide a new mode for rapid homogeneous detection of disease markers.
引用
收藏
页数:12
相关论文
共 57 条
  • [1] Uncoupling of IL-6 signaling and LC3-associated phagocytosis drives immunoparalysis during sepsis
    Akoumianaki, Tonia
    Vaporidi, Katerina
    Diamantaki, Eleni
    Pene, Frederic
    Beau, Remi
    Gresnigt, Mark S.
    Gkountzinopulou, Marina
    Venichaki, Maria
    Drakos, Elias
    El-Benna, Jamel
    Samonis, George
    Le, Kieu T. T.
    Kumar, Vinod
    Georgopoulos, Dimitrios
    van de Veerdonk, Frank L.
    Netea, Mihai G.
    Latge, Jean-Paul
    Chamilos, Georgios
    [J]. CELL HOST & MICROBE, 2021, 29 (08) : 1277 - +
  • [2] Development of a novel homogeneous immunoassay using the engineered luminescent enzyme NanoLuc for the quantification of the mycotoxin fumonisin B1
    Alsulami, Tawfiq
    Nath, Nidhi
    Flemming, Rod
    Wang, Hui
    Zhou, Wenhui
    Yu, Jae-Hyuk
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 177
  • [3] Molecular pathways in sepsis-induced cardiomyocyte pyroptosis: Novel finding on long non-coding RNA ZFAS1/miR-138-5p/SESN2 axis
    An, Li
    Yang, Tianyu
    Zhong, Yi
    Yin, Yongqiang
    Li, Wenqian
    Gao, Hong
    [J]. IMMUNOLOGY LETTERS, 2021, 238 : 47 - 56
  • [4] High Quantum Yield Fluorescent Carbon Nanodots for detection of Fe (III) Ions and Electrochemical Study of Quenching Mechanism
    Arvapalli, Durga M.
    Sheardy, Alex T.
    Alapati, Kalyan C.
    Wei, Jianjun
    [J]. TALANTA, 2020, 209
  • [5] Detection of canine and equine procalcitonin for sepsis diagnosis in veterinary clinic by the development of novel MIP-based SPR biosensors
    Battaglia, F.
    Baldoneschi, V
    Meucci, V
    Intorre, L.
    Minunni, M.
    Scarano, S.
    [J]. TALANTA, 2021, 230
  • [6] Role of non-coding RNAs as biomarkers of deleterious cardiovascular effects in sepsis
    Beltran-Garcia, Jesus
    Osca-Verdegal, Rebeca
    Nacher-Sendra, Elena
    Cardona-Monzonis, Alejandro
    Sanchis-Gomar, Fabian
    Carbonell, Nieves
    V. Pallardo, Federico
    Lavie, Carl J.
    Garcia-Gimenez, Jose Luis
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 2021, 68 : 70 - 77
  • [7] Nanotherapies for sepsis by regulating inflammatory signals and reactive oxygen and nitrogen species: New insight for treating COVID-19
    Chen, Li
    Huang, Qiong
    Zhao, Tianjiao
    Sui, Lihua
    Wang, Shuya
    Xiao, Zuoxiu
    Nan, Yayun
    Ai, Kelong
    [J]. REDOX BIOLOGY, 2021, 45
  • [8] Fiber optic nanogold-linked immunosorbent assay for rapid detection of procalcitonin at femtomolar concentration level
    Chiang, Chang-Yue
    Huang, Tze-Ta
    Wang, Chih-Hui
    Huang, Chun-Jen
    Tsai, Tsung-Heng
    Yu, Sung-Nien
    Chen, Ying-Ting
    Hong, Shih-Wei
    Hsu, Chia-Wei
    Chang, Ting-Chou
    Chau, Lai-Kwan
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 151
  • [9] Green Synthesis of Full-Color Fluorescent Carbon Nanoparticles from Eucalyptus Twigs for Sensing the Synthetic Food Colorant and Bioimaging
    Damera, Deepthi Priyanka
    Manimaran, Raghuraman
    Venuganti, Venkata Vamsi Krishna
    Nag, Amit
    [J]. ACS OMEGA, 2020, 5 (31): : 19905 - 19918
  • [10] Milestones in the development and implementation of FRET-based sensors of intracellular signals: A biological perspective of the history of FRET
    Deal, J.
    Pleshinger, D. J.
    Johnson, S. C.
    Leavesley, S. J.
    Rich, T. C.
    [J]. CELLULAR SIGNALLING, 2020, 75