An artificial enzyme-based assay: DNA detection using a peroxidase-like copper-creatinine complex

被引:29
|
作者
Singh, Amardeep
Patra, Srikanta
Lee, Jeong-Ah
Park, Kang Hyun
Yang, Haesik [1 ]
机构
[1] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 12期
基金
新加坡国家研究基金会;
关键词
Artificial enzyme; DNA sensor; Copper complex; Gold nanoparticle; Peroxidase; ELECTROCHEMICAL DETECTION; CATALYZED OXIDATION; NANOPARTICLES; IMMUNOASSAY; PROTEINS; REDUCTION; OXIDASE; BINDING; LABELS;
D O I
10.1016/j.bios.2011.06.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an artificial enzyme-based DNA assay using a peroxidase-like copper (Cu)-creatinine complex as a catalyst for 3,3',5,5'-tetramethylbenzidine (TMB) oxidation. The assay employs double signal amplification and a homogeneous catalytic reaction: (i) fast catalytic growth of Cu on a gold (Au) nanopartide (NP) label forms a thick Cu layer (first amplification); (ii) dissolution of the Cu layer generates many Cu-creatinine complexes per NP (generation of homogeneous catalysts); (iii) peroxidase-like Cu-creatinine complexes rapidly convert TMB into a colored product (second amplification). To investigate the effect of ligand on the catalytic activities of Cu complexes, the kinetics of catalytic TMB oxidation is tested with and without using imidazole ring-containing ligands (creatinine, imidazole, and poly(L-histidine)). Both fast oxidation of TMB and slow further oxidation of the colored product are required for high signal-to-background ratios. Cu-creatinine complex allows relatively fast oxidation and slow further oxidation. Fast seed-mediated Cu growth on Au NP and slow Cu autonucleation (i.e., slow formation of Cu NP in the absence of Au NP) are also required for high signal-to-background ratios. In tris-EDTA (tris(hydroxymethyl)aminomethane-ethylenediaminetetraacetic acid) buffer (pH 7.7) containing high concentrations of Cu(2+) (90 mM), ascorbic acid (50 mM), and Mg(2+) (200 mM), Cu growth on Au NP is very fast and autonucleation is significantly suppressed. Fast catalytic oxidation by Cu-creatinine complex along with fast Cu growth on Au NP allows a detection limit of 0.1 pM for DNA in a simple microplate format. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4798 / 4803
页数:6
相关论文
共 50 条
  • [1] Assay of creatinine using the peroxidase activity of copper-creatinine complexes
    Pugia, MJ
    Lott, JA
    Wallace, JF
    Cast, TK
    Bierbaum, LD
    CLINICAL BIOCHEMISTRY, 2000, 33 (01) : 63 - 70
  • [2] A Sensitive DNA Enzyme-Based Fluorescent Assay for Bacterial Detection
    Aguirre, Sergio D.
    Ali, M. Monsur
    Salena, Bruno J.
    Li, Yingfu
    BIOMOLECULES, 2013, 3 (03): : 563 - 577
  • [3] Bisubstrate multi-colorimetric assay based on the peroxidase-like activity of Cu2+-triethylamine complex for copper ion detection
    Zhou, Hang-Yu
    Chai, Tong-Qing
    Peng, Li-Jing
    Zhang, Wei-Yi
    Tian, Tao
    Zhang, Hao
    Yang, Feng-Qing
    DYES AND PIGMENTS, 2023, 210
  • [4] Vesicular Mixed Gemini-SDS-Hemin-Imidazole Complex as a Peroxidase-Like Nano Artificial Enzyme
    Gharibi, Hussein
    Moosavi-Movahedi, Zainab
    Javadian, Sohaeila
    Nazari, Khodadad
    Moosavi-Movahedi, Ali A.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2011, 115 (16): : 4671 - 4679
  • [5] A highly selective colorimetric sulfide assay based on the inhibition of the peroxidase-like activity of copper nanoclusters
    Liao, Hong
    Hu, Lianzhe
    Zhang, Yuzhen
    Yu, Xianrong
    Liu, Yilin
    Li, Rong
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [6] A highly selective colorimetric sulfide assay based on the inhibition of the peroxidase-like activity of copper nanoclusters
    Hong Liao
    Lianzhe Hu
    Yuzhen Zhang
    Xianrong Yu
    Yilin Liu
    Rong Li
    Microchimica Acta, 2018, 185
  • [7] A simple colorimetric assay for the detection of metal ions based on the peroxidase-like activity of magnetic nanoparticles
    Kim, Yeon Seok
    Jurng, Jongsoo
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 253 - 257
  • [8] Enzyme-based detection of epoxides using colorimetric assay integrated with smartphone imaging
    Gul, Ijaz
    Bogale, Tadesse Fantaye
    Deng, Jiao
    Chen, Yong
    Fang, Ruiqin
    Feng, Juan
    Tang, Lixia
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2020, 67 (04) : 685 - 692
  • [9] Colorimetric assay of copper ions based on the inhibition of peroxidase-like activity of MoS2 nanosheets
    Chen, Huan
    Li, Zhihong
    Liu, Xueting
    Zhong, Jianhai
    Lin, Tianran
    Guo, Liangqia
    Fu, Fengfu
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 185 : 271 - 275
  • [10] A novel chemiluminescence sensor for sensitive detection of cholesterol based on the peroxidase-like activity of copper nanoclusters
    Shuangjiao Xu
    Yanqin Wang
    Dayun Zhou
    Meng Kuang
    Dan Fang
    Weihua Yang
    Shoujun Wei
    Lei Ma
    Scientific Reports, 6