Tomographic measurement of liquid hold up and effective interfacial area distributions in a column packed with high performance structured packings

被引:53
作者
Aferka, S. [1 ]
Viva, A. [1 ]
Brunazzi, E. [2 ]
Marchot, P. [1 ]
Crine, M. [1 ]
Toye, D. [1 ]
机构
[1] Univ Liege, Lab Chem Engn LGC, B-4000 Liege, Belgium
[2] Univ Pisa, Dept Chem Engn DICCISM, I-56126 Pisa, Italy
关键词
X-ray tomography; Packed columns; High performance structured packings; Liquid hold up distribution; Liquid maldistribution; Effective interfacial area; DISTILLATION-COLUMNS; CONTACTORS; ABSORPTION;
D O I
10.1016/j.ces.2011.01.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this paper, we report on the use of a high energy and high resolution X-ray tomograph to visualize and quantify the distribution of liquid hold up and of gas-liquid interfacial area in a 0.1 m diameter column filled with MellapakPlus 752.Y packing elements. A standard air-water system at room temperature and atmospheric pressure were used. Tomographic measurements have been carried out in a large number of packing cross sections situated at different heights between the top and the bottom of the packed column, giving access to the evolution of axial profiles of liquid hold up and of gas-liquid interfacial area as a function of the operating conditions. Gas-liquid interfacial area values were also measured by a chemical method (CO2 absorption from air into a caustic solution). For the first time, a whole set of gas-liquid interfacial area values evaluated from tomographic images are interestingly compared with values measured by a chemical method. A comparison is also presented with literature models. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3413 / 3422
页数:10
相关论文
共 34 条
  • [1] Adler S., 2000, Vision 2020: Separations Roadmap
  • [2] LIQUID LOAD POINT DETERMINATION IN A REACTIVE DISTILLATION PACKING BY X-RAY TOMOGRAPHY
    Aferka, S.
    Viva, A.
    Brunazzi, E.
    Marchot, P.
    Crine, M.
    Toye, D.
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2010, 88 (04) : 611 - 617
  • [3] Interfacial area measurement in a catalytic distillation packing using high energy X-ray CT
    Aferka, Said
    Marchot, Pierre
    Crine, Michel
    Toye, Dominique
    [J]. CHEMICAL ENGINEERING SCIENCE, 2010, 65 (01) : 511 - 516
  • [4] In situ measurements of the static liquid holdup in Katapak-SP12™ packed column using X-ray tomography
    Aferka, Saied
    Crine, Michel
    Saroha, Anil K.
    Toye, Dominique
    Marchot, Pierre
    [J]. CHEMICAL ENGINEERING SCIENCE, 2007, 62 (21) : 6076 - 6080
  • [5] Mass transfer and hydrodynamic characteristics of new carbon carbon packing: Application to CO2 post-combustion capture
    Alix, Pascal
    Raynal, Ludouic
    Abbe, Francois
    Meyer, Michel
    Prevost, Michel
    Rouzineau, David
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (09) : 1658 - 1668
  • [6] BEHRENS M, 2006, THESIS TU DELFT
  • [7] Modifications to structured packings to increase their capacity
    Bender, P
    Moll, A
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2003, 81 (A1) : 58 - 67
  • [8] Development of a new generation of structured packings for distillation
    Billingham, JF
    Lockett, MJ
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A7) : 583 - 587
  • [9] INTERFACIAL AREA OF MELLAPAK PACKING - ABSORPTION OF 1,1,1-TRICHLOROETHANE BY GENOSORB-300
    BRUNAZZI, E
    NARDINI, G
    PAGLIANTI, A
    PETARCA, L
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 1995, 18 (04) : 248 - 255
  • [10] Bruneton E., 2002, P 7 INT C DIST ABS B, P1