The role of electrical impedance tomography for monitoring during bronchoscopy: A case report

被引:4
作者
Akhavan, Somayeh [1 ]
Hashemian, Seyed MohammadReza [1 ]
机构
[1] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Tehran, Iran
关键词
Electrical impedance tomography; Ventilator-associated pneumonia; Bronchoscopy; ACUTE RESPIRATORY-FAILURE; LUNG INJURY; VENTILATION; DERECRUITMENT; RECRUITMENT; PRESSURE;
D O I
10.1016/j.jcrc.2018.09.028
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous monitoring of lung ventilation can be useful in treating patients admitted to the intensive care unit (ICU). Electrical impedance tomography (EIT) has been used as a relatively new imaging technique for this purpose. We presented a patient with pneumonia who was admitted to the ICU after pulmonary thromboembolism (PTE) required to perform bronchoalveolar lavage (BAL). A drainage procedure and subsequent improvement in pulmonary function were monitored using EIT contributed to the treatment process. The patient has been discharged from the hospital with an improved general condition. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:311 / 313
页数:3
相关论文
共 50 条
  • [21] Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model
    Fagerberg, A.
    Stenqvist, O.
    Aneman, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (02) : 152 - 158
  • [22] A Stable Electrical Impedance Tomography System for Continuous Monitoring of Pulmonary Respiration
    Zhou, Yongkang
    Li, Xiaoqiong
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (06) : 849 - 858
  • [23] Electrical impedance tomography in acute lung injury
    Riera, J.
    Riu, P. J.
    Casan, P.
    Masclans, J. R.
    MEDICINA INTENSIVA, 2011, 35 (08) : 509 - 517
  • [24] Bedside electrical impedance tomography to assist the management of pulmonary embolism: A case report
    Ding, Chenling
    Zhu, Yibo
    Zhang, Shuyi
    Zhao, Zhanqi
    Gao, Yuan
    Li, Zhe
    HELIYON, 2024, 10 (03)
  • [25] Electrical Impedance Tomography for Cardio-Pulmonary Monitoring
    Putensen, Christian
    Hentze, Benjamin
    Muenster, Stefan
    Muders, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (08)
  • [26] Monitoring of breathing pattern at rest by electrical impedance tomography
    Balleza, Marco
    Fornos, Jaume
    Calaf, Nuria
    Feixas, Teresa
    Gonzalez, Mercedes
    Anton, Daniel
    Riu, Pere
    Casan, Pere
    ARCHIVOS DE BRONCONEUMOLOGIA, 2007, 43 (06): : 300 - 303
  • [27] Electrical impedance tomography in monitoring experimental lung injury
    Frerichs, I
    Hahn, G
    Schroder, T
    Hellige, G
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 829 - 836
  • [28] Compressive sensing in electrical impedance tomography for breathing monitoring
    Shiraz, A.
    Khodadad, D.
    Nordebo, S.
    Yerworth, R.
    Frerichs, I
    van Kaam, A.
    Kallio, M.
    Papadouri, T.
    Bayford, R.
    Demosthenous, A.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (03)
  • [29] Combining electrical capacitance and impedance tomography in monitoring processes
    Klosowski, Grzegorz
    Adamkiewicz, Przemyslaw
    Niderla, Konrad
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (02): : 161 - 164
  • [30] Using electrical impedance tomography to monitoring flood banks
    Rymarczyk, Tomasz
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 489 - 494