Organic and inorganic fouling in heat exchangers - Industrial case study: Analysis of fouling state

被引:36
作者
Diaz-Bejarano, E. [1 ,3 ]
Behranvand, E. [2 ]
Coletti, F. [3 ]
Mozdianfard, M. R. [2 ]
Macchietto, S. [1 ,3 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2AZ, England
[2] Univ Kashan, Chem Engn Dept, Engn Fac, Ghotb E Ravandi Bolvd, Kashan, Iran
[3] Imperial Coll London, Hexxcell Ltd, Imperial Coll Incubator, Bessemer Bldg,Level 2, London SW7 2AZ, England
关键词
Crude oil; Fouling; Inorganics; Heat exchanger; Monitoring; Diagnosis; Troubleshooting; EFFECTIVE THERMAL-CONDUCTIVITY; FUEL-FIRED BOILER; FIRESIDE DEPOSITS; RADIANT EMITTANCE; COAL ASH; NETWORK; SIMULATION; MODELS; IMPACT; TUBE;
D O I
10.1016/j.apenergy.2017.10.018
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A comprehensive model-based thereto-hydraulic methodology is used to investigate fouling behaviour in refinery heat exchangers where high concentration of inorganics in the deposits was reported. The method combines a data-driven analysis of plant measurements (including pressure drop) with a model-based analysis using advanced models of shell-and-tube heat exchangers undergoing fouling. A deposit model capable of tracking composition and deposition history was extended to include thermal-conductivity mixing models appropriate for various deposit structures. Substantial new and useful information can be extracted from the plant measurements in comparison to current practice: the thickness, the effective conductivity, and the radial conductivity and composition profiles of the deposits, reflecting the exchanger operation history. Episodes of rapid and acute fouling, and deposition of inorganic materials could be identified and quantified. A validation of the approach was carried out by (i) a comparison of averaged predicted and experimental inorganic weight fractions in a mixed deposit sample collected at the end of run, and (ii) an initial comparison of predicted radial inorganics profiles and experimental ones (obtained with SEM-EDX) in deposits from similar exchangers. Both steps yielded surprisingly good agreement. The study indicates that the method employed represents a new powerful, model based analysis tool for monitoring, diagnosis and troubleshooting of fouling in heat exchangers.
引用
收藏
页码:1250 / 1266
页数:17
相关论文
共 87 条
[1]   Roughness and constriction effects on heat transfer in crystallization fouling [J].
Albert, Florian ;
Augustin, Wolfgang ;
Scholl, Stephan .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (03) :499-509
[2]   EFFECTIVE THERMAL-CONDUCTIVITY OF COAL ASH DEPOSITS AT MODERATE TO HIGH-TEMPERATURES [J].
ANDERSON, DW ;
VISKANTA, R ;
INCROPERA, FP .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1987, 109 (02) :215-221
[3]  
[Anonymous], 2000, CRC MAT SCI ENG HDB, DOI DOI 10.1201/9781420038408
[4]  
[Anonymous], 2019, HEAT EXCHANGER FOULI
[5]  
Atkins G.T., 1962, PETRO CHEM ENG, V34, P20
[6]  
Behranvand E, 2017, CROSS SECTIONAL EXAM
[7]  
Behranvand E, 2017, COMPREHENSIVE INVEST
[8]   Observation of an Isokinetic Temperature and Compensation Effect for High-Temperature Crude Oil Fouling [J].
Bennett, Christopher A. ;
Kistler, R. Stanley ;
Nangia, Krish ;
Al-Ghawas, Walid ;
Al-Hajji, Nadia ;
Al-Jemaz, Ahmad .
HEAT TRANSFER ENGINEERING, 2009, 30 (10-11) :794-804
[9]  
BOOW J, 1969, J I FUEL, V42, P412
[10]  
Bott TR., 1995, Fouling of Heat Exchangers