Fast-updating and nonrepeating Lissajous image reconstruction method for capturing increased dynamic information

被引:37
作者
Hoy, Christopher L. [1 ]
Durr, Nicholas J. [2 ]
Ben-Yakar, Adela [1 ,2 ]
机构
[1] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
MICROSCOPE;
D O I
10.1364/AO.50.002376
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a fast-updating Lissajous image reconstruction methodology that uses an increased image frame rate beyond the pattern repeat rate generally used in conventional Lissajous image reconstruction methods. The fast display rate provides increased dynamic information and reduced motion blur, as compared to conventional Lissajous reconstruction, at the cost of single-frame pixel density. Importantly, this method does not discard any information from the conventional Lissajous image reconstruction, and frames from the complete Lissajous pattern can be displayed simultaneously. We present the theoretical background for this image reconstruction methodology along with images and video taken using the algorithm in a custom-built miniaturized multiphoton microscopy system. (C) 2011 Optical Society of America
引用
收藏
页码:2376 / 2382
页数:7
相关论文
共 9 条
[1]   Micromachined scanning confocal optical microscope [J].
Dickensheets, DL ;
Kino, GS .
OPTICS LETTERS, 1996, 21 (10) :764-766
[2]   In vivo brain imaging using a portable 3.9 gram two-photon fluorescence microendoscope [J].
Flusberg, BA ;
Lung, JC ;
Cocker, ED ;
Anderson, EP ;
Schnitzer, MJ .
OPTICS LETTERS, 2005, 30 (17) :2272-2274
[3]   A miniature head-mounted two-photon microscope: High-resolution brain imaging in freely moving animals [J].
Helmchen, F ;
Fee, MS ;
Tank, DW ;
Denk, W .
NEURON, 2001, 31 (06) :903-912
[4]   Miniaturized probe for femtosecond laser microsurgery and two-photon imaging [J].
Hoy, Christopher L. ;
Durr, Nicholas J. ;
Chen, Pengyuan ;
Piyawattanametha, Wibool ;
Ra, Hyejun ;
Solgaard, Olav ;
Ben-Yakar, Adela .
OPTICS EXPRESS, 2008, 16 (13) :9996-10005
[5]  
IIOY CL, 2011, OPT EXPRESS, V19, P10536
[6]   DETERMINANTS OF THE CRITICAL FLICKER-FUSION THRESHOLD [J].
LANDIS, C .
PHYSIOLOGICAL REVIEWS, 1954, 34 (02) :259-286
[7]  
Lissajous JA., 1855, CR Hebd. Seances Acad. Sci, V41, P93
[8]   Micromirror-scanned dual-axis confocal microscope utilizing a gradient-index relay lens for image guidance during brain surgery [J].
Liu, Jonathan T. C. ;
Mandella, Michael J. ;
Loewke, Nathan O. ;
Haeberle, Henry ;
Ra, Hyejun ;
Piyawattanametha, Wibool ;
Solgaard, Olav ;
Kino, Gordon S. ;
Contag, Christopher H. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
[9]   Miniaturized multiphoton microscope with a 24Hz frame-rate [J].
Liu, Tzu-Ming ;
Chan, Ming-Che ;
Chen, I-Hsiu ;
Chia, Shih-Hsuan ;
Sun, Chi-Kuang .
OPTICS EXPRESS, 2008, 16 (14) :10501-10506