Dosimetric characterization of two radium sources for retrospective dosimetry studies

被引:2
作者
Candela-Juan, C. [1 ,2 ]
Karlsson, M. [3 ]
Lundell, M. [4 ,5 ]
Ballester, F. [2 ]
Tedgren, A. Carlsson [3 ,6 ]
机构
[1] La Fe Univ & Polytech Hosp, Dept Radiat Oncol, Valencia 46026, Spain
[2] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Spain
[3] Linkoping Univ, Dept Med & Hlth Sci, Div Radiol Sci, SE-58185 Linkoping, Sweden
[4] Karolinska Univ Hosp, Dept Med Phys & Oncol, SE-17176 Stockholm, Sweden
[5] Karolinska Inst, SE-17176 Stockholm, Sweden
[6] Swedish Radiat Safety Author, SE-17116 Stockholm, Sweden
关键词
brachytherapy; retrospective dosimetry; radium; TG-43; formalism; EMITTING BRACHYTHERAPY SOURCES; BREAST-CANCER RISK; SURFACE APPLICATION; PLANNING SYSTEMS; DOSE CALCULATION; SKIN HEMANGIOMA; AAPM; RADIOTHERAPY; THERAPY; RECOMMENDATIONS;
D O I
10.1118/1.4916685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: During the first part of the 20th century, Ra-226 was the most used radionuclide for brachytherapy. Retrospective accurate dosimetry, coupled with patient follow up, is important for advancing knowledge on long-term radiation effects. The purpose of this work was to dosimetrically characterize two Ra-226 sources, commonly used in Sweden during the first half of the 20th century, for retrospective dose-effect studies. Methods: An 8 mg Ra-226 tube and a 10 mg Ra-226 needle, used at Radiumhemmet (Karolinska University Hospital, Stockholm, Sweden), from 1925 to the 1960s, were modeled in two independent Monte Carlo (MC) radiation transport codes: GEANT4 and MCNP5. Absorbed dose and collision kerma around the two sources were obtained, from which the TG-43 parameters were derived for the secular equilibrium state. Furthermore, results from this dosimetric formalism were compared with results from a MC simulation with a superficial mould constituted by five needles inside a glass casing, placed over a water phantom, trying to mimic a typical clinical setup. Calculated absorbed doses using the TG-43 formalism were also compared with previously reported measurements and calculations based on the Sievert integral. Finally, the dose rate at large distances from a Ra-226 point-like-source placed in the center of 1 m radius water sphere was calculated with GEANT4. Results: TG-43 parameters [including gL(r), F(r,theta), Lambda, and s(K)] have been uploaded in spreadsheets as additional material, and the fitting parameters of a mathematical curve that provides the dose rate between 10 and 60 cm from the source have been provided. Results from TG-43 formalism are consistent within the treatment volume with those of a MC simulation of a typical clinical scenario. Comparisons with reported measurements made with thermoluminescent dosimeters show differences up to 13% along the transverse axis of the radium needle. It has been estimated that the uncertainty associated to the absorbed dose within the treatment volume is 10%-15%, whereas uncertainty of absorbed dose to distant organs is roughly 20%-25%. Conclusions: The results provided here facilitate retrospective dosimetry studies of Ra-226 using modern treatment planning systems, which may be used to improve knowledge on long term radiation effects. It is surely important for the epidemiologic studies to be aware of the estimated uncertainty provided here before extracting their conclusions. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:2132 / 2142
页数:11
相关论文
共 48 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
Anderson L. L., 1990, INT BRACH PHYS BIOL
[3]  
[Anonymous], Sources, effects and risks of ionizing radiation: UNSCEAR 2020/2021 Report. Volume II SCIENTIFIC ANNEX B: Levels and effects of radiation exposure due to the accident at the Fukushima Daiichi Nuclear Power Station: implications of information published since the UNSCEAR 2013 Report
[4]  
[Anonymous], DOSIMETRIE CURIETHER
[5]  
Aronowitz Jesse N, 2002, Brachytherapy, V1, P167
[6]   A DETERMINATION OF THE GAMMA-RAY EMISSION OF RADIUM [J].
ATTIX, FH ;
RITZ, VH .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1957, 59 (05) :293-305
[7]   Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons [J].
Ballester, Facundo ;
Granero, Domingo ;
Perez-Calatayud, Jose ;
Melhus, Christopher S. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2009, 36 (09) :4250-4256
[8]  
Bateman H, 1910, P CAMB PHILOS SOC, V15, P423
[9]   Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: Current status and recommendations for clinical implementation [J].
Beaulieu, Luc ;
Tedgren, Asa Carlsson ;
Carrier, Jean-Francois ;
Davis, Stephen D. ;
Mourtada, Firas ;
Rivard, Mark J. ;
Thomson, Rowan M. ;
Verhaegen, Frank ;
Wareing, Todd A. ;
Williamson, Jeffrey F. .
MEDICAL PHYSICS, 2012, 39 (10) :6208-6236
[10]   RADIATION-DOSE AND SECOND CANCER RISK IN PATIENTS TREATED FOR CANCER OF THE CERVIX [J].
BOICE, JD ;
ENGHOLM, G ;
KLEINERMAN, RA ;
BLETTNER, M ;
STOVALL, M ;
LISCO, H ;
MOLONEY, WC ;
AUSTIN, DF ;
BOSCH, A ;
COOKFAIR, DL ;
KREMENTZ, ET ;
LATOURETTE, HB ;
MERRILL, JA ;
PETERS, LJ ;
SCHULZ, MD ;
STORM, HH ;
BJORKHOLM, E ;
PETTERSSON, F ;
BELL, CMJ ;
COLEMAN, MP ;
FRASER, P ;
NEAL, FE ;
PRIOR, P ;
CHOI, NW ;
HISLOP, TG ;
KOCH, M ;
KREIGER, N ;
ROBB, D ;
ROBSON, D ;
THOMSON, DH ;
LOCHMULLER, H ;
VONFOURNIER, D ;
FRISCHKORN, R ;
KJORSTAD, KE ;
RIMPELA, A ;
PEJOVIC, MH ;
KIRN, VP ;
STANKUSOVA, H ;
BERRINO, F ;
SIGURDSSON, K ;
HUTCHISON, GB ;
MACMAHON, B .
RADIATION RESEARCH, 1988, 116 (01) :3-55