Online 4-D CT Estimation for Patient-Specific Respiratory Motion Based on Real-Time Breathing Signals

被引:0
作者
He, Tiancheng [1 ,2 ]
Xue, Zhong [1 ]
Xie, Weixin [2 ]
Wong, Stephen T. C. [1 ]
机构
[1] Methodist Hosp, Weil Cornell Med Coll, Ctr Bioengn & Informat, Methodist Hosp Res Inst & Dept Radiol, 6535 Fannin, Houston, TX 77030 USA
[2] Shenzen Univ, Intelligent Informat Inst, \, Shenzhen, Peoples R China
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III | 2010年 / 6363卷
关键词
Image-guided intervention; respiratory motion; 4-D CT; K-PCA; least squares support vector machine; IMAGE; SEGMENTATION; REGISTRATION; DEFORMATION; VALIDATION; MODEL;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
In image-guided lung intervention, the electromagnetic (EM) tracked needle can be visualized in a pre-procedural CT by registering the EM tracking and the CT coordinate systems. However, there exist discrepancies between the static pre-procedural CT and the patient due to respiratory motion. This paper proposes an online 4-D CT estimation approach to patient-specific respiratory motion compensation. First, the motion patterns between 4-D CT data and respiratory signals such as fiducials from a number of patients are trained in a template space after image registration. These motion patterns can be used to estimate the patient-specific serial CTs from a static 3-D CT and the real-time respiratory signals of that patient, who do not generally take 4-D CTs. Specifically, the respiratory lung field motion vectors are projected onto the Kernel Principal Component Analysis (K-PCA) space, and a motion estimation model is constructed to estimate the lung field motion from the fiducial motion using the ridge regression method based on the least squares support vector machine (LS-SVM). The algorithm can be performed onsite prior to the intervention to generate the serial CT images according to the respiratory signals in advance, and the estimated CTs can be visualized in real-time during the intervention. In experiments, we evaluated the algorithm using leave-one-out strategy on 30 4-D CT data, and the results showed that the average errors of the lung field surfaces are 1.63mm.
引用
收藏
页码:392 / +
页数:2
相关论文
共 14 条
[1]   Fast cross-validation algorithms for least squares support vector machine and kernel ridge regression [J].
An, Senjian ;
Liu, Wanquan ;
Venkatesh, Svetha .
PATTERN RECOGNITION, 2007, 40 (08) :2154-2162
[2]  
[Anonymous], 2001, LNCS, DOI DOI 10.1007/3-540-45468-3_62
[3]  
HE T, 2010, LNCS, V6135
[4]  
Kim KI, 2005, IEEE T PATTERN ANAL, V27, P1351, DOI 10.1109/TPAMI.2005.181
[5]   The pre-image problem in kernel methods [J].
Kwok, JTY ;
Tsang, IWH .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 2004, 15 (06) :1517-1525
[6]   Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration [J].
Lu, W. ;
Song, J. H. ;
Christensen, G. E. ;
Parikh, P. J. ;
Zhao, T. ;
Hubenschmidt, J. P. ;
Bradley, J. D. ;
Low, D. A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03) :S606-S607
[7]   A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy [J].
McClelland, Jamie R. ;
Blackall, Jane M. ;
Tarte, Segolene ;
Chandler, Adam C. ;
Hughes, Simon ;
Ahmad, Shahreen ;
Landau, David B. ;
Hawkes, David J. .
MEDICAL PHYSICS, 2006, 33 (09) :3348-3358
[8]  
Sundaram TA, 2004, LECT NOTES COMPUT SC, V3217, P1000
[9]  
von Siebenthal M, 2007, LECT NOTES COMPUT SC, V4791, P659
[10]   CLASSIC: Consistent longitudinal alignment and segmentation for serial image computing [J].
Xue, Z ;
Shen, DG ;
Davatzikos, C .
NEUROIMAGE, 2006, 30 (02) :388-399