Multivariate optimization of a procedure for Cr and Co ultratrace determination in vegetal samples using GF AAS after cloud-point extraction

被引:20
作者
Bezerra, Marcos A. [1 ,2 ]
Nogueira, Ana Rita A. [3 ,4 ]
Lemos, Sherlan G. [3 ,4 ]
Ferreira, Sergio L. C. [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, Grp Pesquisa Quim Analit, BR-40170290 Salvador, BA, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Quim & Exatas, BR-45200190 Jequie, BA, Brazil
[3] Embrapa Pecuaria Sudeste, Grp Analise Instrumental Aplicada, BR-13560970 Sao Carlos, SP, Brazil
[4] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
chromium; cloud-point extraction; cobalt; Dohelert design; GF AAS; vegetal samples;
D O I
10.1080/03067310701581974
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents the development of a procedure for the determination of Cr and Co from vegetal samples using graphite-furnace atomic absorption spectrometry after cloud-point extraction. The procedure is based on extraction of metals from micellar media of octylphenoxypolythoxy-ethanol (Triton X-114) after complexing the metals with 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol [5-Br-PADAP]. A Doehlert design was used to optimize the pyrolysis and atomization temperatures and pyrolysis time in the determination of analytes trapped in the micellar phase. Ascorbic acid and palladium were used as chemical modifiers, allowing a higher pyrolysis temperature without analyte losses. Enrichment factors of 26.2 and 41.0, along with detection limits (3 sigma(B)) of 23 and 12 ng L-1 for Cr and Co, respectively, were found. The precision expressed as relative standard deviation was 5.4 and 8.4% for metal concentrations of 0.5 mu g L-1 (n = 8) for Cr and Co, respectively. The accuracy was evaluated through the analysis of the certified reference material NIST 1515 (apple leaves). The procedure developed in this study was applied to the determination of Cr and Co concentrations in vegetal leaf samples.
引用
收藏
页码:131 / 140
页数:10
相关论文
共 35 条
[1]   Application of factorial design and Doehlert matrix in the optimisation of instrumental parameters for direct determination of silicon in naphtha using graphite furnace atomic absorption spectrometry [J].
Amaro, JAD ;
Ferreira, SLC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (02) :246-249
[2]  
AUCEJO ARM, 2007, ANAL CHIM ACTA, V581, P78
[3]   EXPERIMENTAL AND THEORETICAL-STUDIES OF THE FACTORS THAT INFLUENCE THE DETERMINATION OF MOLYBDENUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROSCOPY [J].
BENZO, Z ;
ARAUJO, P ;
SIERRAALTA, A ;
RUETTE, F .
ANALYTICAL CHEMISTRY, 1993, 65 (08) :1107-1113
[4]   Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction [J].
Bezerra, MD ;
Conceiçao, ALB ;
Ferreira, SLC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (03) :798-803
[5]   Cloud-point extraction for the determination of Cd, Pb and Pd in blood by electrothermal atomic absorption spectrometry, using Ir or Ru as permanent modifiers [J].
Borges, DLG ;
da Veiga, MAMS ;
Frescura, VLA ;
Welz, B ;
Curtius, AJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :501-507
[6]   OPTIMIZATION OF ANALYTICAL METHODS BY USING DOEHLERTS DESIGNS [J].
BOSQUESENDRA, JM ;
NECHAR, M ;
RODRIGUEZ, LC ;
MOLINA, MFM .
ANALYTICAL PROCEEDINGS, 1995, 32 (09) :375-377
[7]  
Box GEP, 1978, STAT EXPT
[8]   Sequential response surface methodology for multioptimization in analytical chemistry with three-variable Doehlert designs [J].
Campana, AMG ;
Rodriguez, LC ;
Gonzalez, AL ;
Barrero, FA ;
Ceba, MR .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :237-246
[9]   Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Xiao, SM ;
Wu, XH ;
Fang, KM ;
Liu, WH .
TALANTA, 2005, 67 (05) :992-996
[10]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222