Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease

被引:22
作者
Ahn, Su Joa [1 ]
Lee, Jeong Min [1 ,2 ]
Chang, Won [1 ]
Lee, Sang Min [1 ]
Kang, Hyo-Jin [1 ]
Yang, Hyunkyung [1 ]
Yoon, Jeong Hee [1 ]
Park, Sae Jin [1 ]
Han, Joon Koo [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Inst Radiat Med, Coll Med, Seoul 03080, South Korea
关键词
Liver fibrosis; Liver stiffness; Ultrasound elastography; Shear wave elastography; IMPULSE ARFI ELASTOGRAPHY; 1 BASIC PRINCIPLES; HEPATITIS-C VIRUS; CLINICAL-USE; TRANSIENT ELASTOGRAPHY; EFSUMB GUIDELINES; WFUMB GUIDELINES; CUTOFF VALUES; FIBROSIS; RECOMMENDATIONS;
D O I
10.3348/kjr.2017.18.6.926
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To assess intra- and inter-observer reproducibility of a new point shear wave elastography technique (pSWE, S-Shearwave, Samsung Medison) and compare its accuracy in assessing liver stiffness (LS) with an established pSWE technique (Virtual Touch Quantification, VTQ). Materials and Methods: Thirty-three patients were enrolled in this Institutional Review Board-approved prospective study. LS values were measured by VTQ on an Acuson S2000 system (Siemens Healthineer) and S-Shearwave on an RS-80A (Samsung Medison) in the same session, followed by two further S-Shearwave sessions for inter- and intra-observer variation at 8-hour intervals. The technical success rate (SR) and reliability of the measurements of both pSWE techniques were compared. The intra- and inter-observer reproducibility of S-Shearwave was determined by intraclass correlation coefficients (ICCs). LS values were measured by both methods of pSWE. The diagnostic performance in severe fibrosis (F >= 3) and cirrhosis (F = 4) was evaluated using the receiver operating characteristics curve analysis and the Obuchowski measure with the LS values of transient elastography as the referenced standard. Results: The VTQ (100%, 33/33) and S-Shearwave (96.9%, 32/33) techniques did not display a significant difference in technical SR (p = 0.63) or reliability of LS measurements (96.9%, 32/33; 93.9%, 30/32, respectively, p = 0.61). The interand intra-observer agreement for LS measurements using the S-Shearwave technique was excellent (ICC = 0.98 and 0.99, respectively). The mean LS values of both pSWE techniques were not significantly different and exhibited a good correlation (r = 0.78). To detect F = 3 and F = 4, VTQ and S-Shearwave showed comparable diagnostic accuracy as indicated by the following outcomes: areas under receiver operating characteristics curve (AUROC) = 0.87 (95% confidence intervals [CI] 0.70-0.96), 0.89 for VTQ (95% CI 0.74-0.97), respectively; and AUROC = 0.84 (95% CI 0.67-0.94), 0.94 (95% CI 0.80-0.99) for S-Shearwave (p > 0.48), respectively. The Obuchowski measures were similarly high for S-Shearwave and VTQ (0.94 vs. 0.95). Conclusion: S-Shearwave shows excellent inter- and intra-observer agreement and diagnostic effectiveness comparable to VTQ in detecting LS.
引用
收藏
页码:926 / 935
页数:10
相关论文
共 49 条
  • [1] Ultrasound-based transient elastography for the detection of hepatic fibrosis in patients with recurrent hepatitis C virus after liver transplantation: A systematic review and meta-analysis
    Adebajo, Corlan O.
    Talwalkar, Jayant A.
    Poterucha, John J.
    Kim, W. Ray
    Charlton, Michael R.
    [J]. LIVER TRANSPLANTATION, 2012, 18 (03) : 323 - 331
  • [2] [Anonymous], 2015, J HEPATOL, V63, P237, DOI 10.1016/j.jhep.2015.04.006
  • [3] Elastography in Chronic Liver Disease: Modalities, Techniques, Limitations, and Future Directions
    Babu, Aparna Srinivasa
    Wells, Michael L.
    Teytelboym, Oleg M.
    Mackey, Justin E.
    Miller, Frank H.
    Yeh, Benjamin M.
    Ehman, Richard L.
    Venkatesh, Sudhakar K.
    [J]. RADIOGRAPHICS, 2016, 36 (07) : 1987 - 2006
  • [4] EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology
    Bamber, J.
    Cosgrove, D.
    Dietrich, C. F.
    Fromageau, J.
    Bojunga, J.
    Calliada, F.
    Cantisani, V.
    Correas, J. -M.
    D'Onofrio, M.
    Drakonaki, E. E.
    Fink, M.
    Friedrich-Rust, M.
    Gilja, O. H.
    Havre, R. F.
    Jenssen, C.
    Klauser, A. S.
    Ohlinger, R.
    Saftoiu, A.
    Schaefer, F.
    Sporea, I.
    Piscaglia, F.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2013, 34 (02): : 169 - 184
  • [5] The Role of Diet and Nutritional Intervention for the Management of Patients with NAFLD
    Barrera, Francisco
    George, Jacob
    [J]. CLINICS IN LIVER DISEASE, 2014, 18 (01) : 91 - +
  • [6] NONINVASIVE IN VIVO LIVER FIBROSIS EVALUATION USING SUPERSONIC SHEAR IMAGING: A CLINICAL STUDY ON 113 HEPATITIS C VIRUS PATIENTS
    Bavu, Eric
    Gennisson, Jean-Luc
    Couade, Mathieu
    Bercoff, Jeremy
    Mallet, Vincent
    Fink, Mathias
    Badel, Anne
    Vallet-Pichard, Anais
    Nalpas, Bertrand
    Tanter, Mickael
    Pol, Stanislas
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09) : 1361 - 1373
  • [7] BEDOSSA P, 1994, HEPATOLOGY, V20, P15
  • [8] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [9] Bota S, 2015, MED ULTRASON, V17, P200, DOI 10.11152/mu.2013.2066.172.arfi
  • [10] INTRA- AND INTEROPERATOR REPRODUCIBILITY OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY-PRELIMINARY RESULTS
    Bota, Simona
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    Danila, Mirela
    Costachescu, Dan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07) : 1103 - 1108