Wearable Millimeter-Wave Device for Contactless Measurement of Arterial Pulses

被引:64
作者
Johnson, Jessi E. [1 ,2 ]
Shay, Oliver [2 ]
Kim, Chris [2 ,3 ]
Liao, Catherine [2 ]
机构
[1] AltruEM Consulting LLC, San Francisco, CA 94105 USA
[2] Blumio Inc, San Francisco, CA 94105 USA
[3] GE Healthcare, Chicago, IL 60661 USA
基金
美国国家科学基金会;
关键词
Radar antennas; Skin; Biomedical monitoring; Antenna measurements; Millimeter wave radar; Blood pressure; electromagnetic propagation; FMCW radar; heart rate; medical simulation; millimeter wave radar; radar antennas; vital sign detection; wearables; TRANSIT-TIME; PRESSURE; NONCONTACT; ANTENNA;
D O I
10.1109/TBCAS.2019.2948581
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable monitors for measuring vital signs such as blood pressure will greatly impact the medical field. This work presents a millimeter-wave, radar-based system for performing accurate measurements of arterial pulse waveforms without contacting the region that is pulsing. Electromagnetic and radar-system simulation models are utilized to demonstrate the viability and safety of this approach. This is followed by hardware/software implementation and a study on 12 human subjects. Measured radial arterial waveforms exhibit signal strengths that are well above the noise floor of the system and a morphology that would be expected in an arterial pulse. Finally, comparison of the radar-based signals with a reference tonometer indicates a strong correlation between waveforms, as well as similar spectral signatures. The results observed suggest a millimeter-wave based approach for arterial pulse detection is very promising for future applications in pulse wave analysis and pulse transit time measurement for blood pressure tracking.
引用
收藏
页码:1525 / 1534
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 2017, BGT60TR24B TRANSC CH
[2]  
[Anonymous], 2010, Standard C95.1a-2010
[3]   Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment [J].
Avolio, Alberto P. ;
Butlin, Mark ;
Walsh, Andrew .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (01) :R1-R47
[4]  
Barak I.S., 2017, U.S. Patent., Patent No. [Grant 9,713,434 B2, 9713434]
[5]   Blood Pressure Estimation Using Pulse Transit Time From Bioimpedance and Continuous Wave Radar [J].
Buxi, Dilpreet ;
Redout, Jean-Michel ;
Yuce, Mehmet Rasit .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (04) :917-927
[6]   SeismoWatch: Wearable cuffless blood pressure monitoring using pulse transit time [J].
Carek, Andrew ;
Conant, Jordan ;
Joshi, Anirudh ;
Kang, Hyolim ;
Inan, Omer .
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, 2017, 1 (03)
[7]   60-GHz Millimeter-Wave Life Detection System (MLDS) for Noncontact Human Vital-Signal Monitoring [J].
Chuang, Huey-Ru ;
Kuo, Hsin-Chih ;
Lin, Fu-Ling ;
Huang, Tzuen-Hsi ;
Kuo, Chi-Shin ;
Ou, Ya-Wen .
IEEE SENSORS JOURNAL, 2012, 12 (03) :602-609
[8]   Pulse Wave Analysis by Applanation Tonometry for the Measurement of Arterial Stiffness [J].
Doupis, John ;
Papanas, Nikolaos ;
Cohen, Alison ;
McFarlan, Lyndsay ;
Horton, Edward .
OPEN CARDIOVASCULAR MEDICINE JOURNAL, 2016, 10 :188-195
[9]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[10]   An Accurate Bioimpedance Measurement System for Blood Pressure Monitoring [J].
Huynh, Toan Huu ;
Jafari, Roozbeh ;
Chung, Wan-Young .
SENSORS, 2018, 18 (07)