Prevalence, characteristics, and predictors of endocardial and nonendocardial conduction gaps during local impedance-guided extensive pulmonary vein isolation of atrial fibrillation with high-resolution mapping

被引:9
作者
Nakamura, Kohki [1 ]
Sasaki, Takehito [1 ]
Minami, Kentaro [1 ]
Take, Yutaka [1 ]
Inoue, Mitsuho [1 ]
Sasaki, Wataru [1 ]
Kishi, Shohei [1 ]
Yoshimura, Shingo [1 ]
Okazaki, Yoshinori [1 ]
Motoda, Hiroyuki [1 ]
Niijima, Katsura [1 ]
Miki, Yuko [1 ]
Goto, Koji [1 ]
Kaseno, Kenichi [1 ]
Yamashita, Eiji [1 ]
Koyama, Keiko [2 ]
Funabashi, Nobusada [3 ]
Naito, Shigeto [1 ]
机构
[1] Gunma Prefectural Cardiovasc Ctr, Div Cardiol, 3-12 Kameizumi Machi, Maebashi, Gumma 3710004, Japan
[2] Gunma Prefectural Cardiovasc Ctr, Div Radiol, Maebashi, Gumma, Japan
[3] Chiba Univ, Dept Cardiovasc Sci & Med, Grad Sch Med, Chiba, Chiba, Japan
关键词
atrial fibrillation; catheter ablation; conduction gap; high-resolution mapping; local impedance; pulmonary vein isolation; CATHETER ABLATION; CONNECTIONS; RELEVANCE;
D O I
10.1111/jce.15152
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Local impedance (LI) drops during radiofrequency ablation can predict lesion formation. Some conduction gaps during pulmonary vein isolation (PVI) can be associated with nonendocardial connections. This study aimed to investigate the incidence, characteristics, and predictors of endocardial and nonendocardial conduction gaps during an LI-guided PVI. Methods and Results We prospectively enrolled 157 consecutive patients undergoing an initial LI-guided extensive PVI of atrial fibrillation (AF). After the first-pass encirclement, the residual conduction gaps and reconnected gaps were mapped using Rhythmia (Boston Scientific) and a mini-basket catheter. Right and left PV (RPV/LPV) gaps were observed in 22.3% and 18.5% of the patients, respectively: 27 endocardial and 49 nonendocardial gaps. The carina regions were common sites for the gaps (51 carina-related vs. 25 noncarina-related). The carina-related gaps consisted of more nonendocardial gaps than endocardial gaps (RPVs: 90.0% vs. 10.0%, p = .001; LPVs: 76.2% vs. 23.8%, p < .001). A univariate analysis revealed that paroxysmal AF and the left atrial (LA) volume index for RPV endocardial gaps (odds ratio [OR]: 8.640 and 0.946; p = .043 and 0.009), minor right inferior PV diameter for RPV nonendocardial gaps (OR: 1.165; p = .028), and major left inferior PV diameter for LPV endocardial gaps (OR: 1.233; p = .028) were significant predictors. Conclusions During the LI-guided PVI, approximately two-thirds of the conduction gaps were nonendocardial. The carina regions had more conduction gaps than noncarina regions, which was due to the presence of nonendocardial connections. Paroxysmal AF, a lower LA volume index, and larger inferior PV diameters may increase the risk of conduction gaps.
引用
收藏
页码:2045 / 2059
页数:15
相关论文
共 28 条
  • [1] Morphological evidence of muscular connections between contiguous pulmonary venous orifices: Relevance of the interpulmonary isthmus for catheter ablation in atrial fibrillation
    Cabrera, Jose Angel
    Ho, Siew Yen
    Climent, Vicente
    Fuertes, Beatriz
    Murillo, Margarita
    Sanchez-Quintana, Damian
    [J]. HEART RHYTHM, 2009, 6 (08) : 1192 - 1198
  • [2] Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1016/j.hrthm.2017.07.009, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
  • [3] Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation
    Cappato, Riccardo
    Calkins, Hugh
    Chen, Shih-Ann
    Davies, Wyn
    Iesaka, Yoshito
    Kalman, Jonathan
    Kim, You-Ho
    Klein, George
    Natale, Andrea
    Packer, Douglas
    Skanes, Allan
    Ambrogi, Federico
    Biganzoli, Elia
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) : 32 - 38
  • [4] A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation
    Dhillon, Gurpreet
    Ahsan, Syed
    Honarbakhsh, Shohreh
    Lim, Wei
    Baca, Marco
    Graham, Adam
    Srinivasan, Neil
    Sawhney, Vinit
    Sporton, Simon
    Schilling, Richard J.
    Chow, Anthony
    Ginks, Matthew
    Sohal, Manav
    Gallagher, Mark M.
    Hunter, Ross J.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (03) : 357 - 365
  • [5] Standardized pulmonary vein isolation workflow to enclose veins with contiguous lesions: the multicentre VISTAX trial
    Duytschaever, Mattias
    Vijgen, Johan
    De Potter, Tom
    Scherr, Daniel
    Van Herendael, Hugo
    Knecht, Sebastien
    Kobza, Richard
    Berte, Benjamin
    Sandgaard, Niels
    Albenque, Jean-Paul
    Szeplaki, Gabor
    Stevenhagen, Yorick Jeroen
    Taghji, Philippe
    Wright, Matthew
    Macours, Nathalie
    Gupta, Dhiraj
    [J]. EUROPACE, 2020, 22 (11): : 1645 - 1652
  • [6] A novel assessment of local impedance during catheter ablation: initial experience in humans comparing local and generator measurements
    Gunawardene, Melanie
    Muenkler, Paula
    Eickholt, Christian
    Akbulak, Ruken Oe
    Jularic, Mario
    Klatt, Niklas
    Hartmann, Jens
    Dinshaw, Leon
    Jungen, Christiane
    Moser, Julia M.
    Merbold, Lydia
    Willems, Stephan
    Meyer, Christian
    [J]. EUROPACE, 2019, 21 : 34 - 42
  • [7] Left Atrial Anatomy Revisited
    Ho, Siew Yen
    Angel Cabrera, Jose
    Sanchez-Quintana, Damian
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (01) : 220 - U364
  • [8] Atrial structure and fibres:: morphologic bases of atrial conduction
    Ho, SY
    Anderson, RH
    Sánchez-Quintana, D
    [J]. CARDIOVASCULAR RESEARCH, 2002, 54 (02) : 325 - 336
  • [9] Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results
    Hussein, Ahmed
    Das, Moloy
    Riva, Stefania
    Morgan, Maureen
    Ronayne, Christina
    Sahni, Ankita
    Shaw, Matthew
    Todd, Derick
    Hall, Mark
    Modi, Simon
    Natale, Andrea
    Dello Russo, Antonio
    Snowdon, Richard
    Gupta, Dhiraj
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (09) : e006576
  • [10] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131