Monitoring Steel Bolted Joints during a Monotonic Tensile Test Using Linear and Nonlinear Lamb Wave Methods: A Feasibility Study

被引:13
作者
Rucka, Magdalena [1 ]
机构
[1] Gdansk Univ Technol, Fac Civil & Environm Engn, Dept Mech Mat & Struct, Narutowicza 11-12, PL-80233 Gdansk, Poland
来源
METALS | 2018年 / 8卷 / 09期
关键词
steel bolted joint; mechanical degradation; tensile loading; wave propagation; structural health monitoring; THERMAL PROTECTION PANELS; DAMAGE DETECTION; PIEZOELECTRIC SENSORS; ULTRASONIC-WAVES; CONCRETE; BEHAVIOR; PZT; IMPEDANCE; PLATE;
D O I
10.3390/met8090683
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The structural integrity of steel bolted joints may be compromised due to excessive loading. Therefore, condition assessment and the detection of potential defects before they cause a failure have become a major issue. The paper is focused on the condition monitoring of a bolted lap joint subjected to progressive degradation in a tensile test. The inspection used Lamb waves propagated through the overlap area. Wave propagation signals were registered automatically by means of piezoelectric transducers. Two damage indices were defined based on linear and nonlinear features of Lamb waves. The use of a network of piezoelectric transducers and the analysis of multiple signals instead of single ones was proved to effectively monitor the state of the bolted joint. The obtained results showed that the method enabled to detect selected stages of the degradation process and to characterize the reduction of the contact area between the plates in the overlap area.
引用
收藏
页数:14
相关论文
共 49 条
[1]   Failure Analysis of High Strength Galvanized Bolts Used in Steel Towers [J].
Alberto Alvarez, Jose ;
Lacalle, Roberto ;
Arroyo, Borja ;
Cicero, Sergio ;
Gutierrez-Solana, Federico .
METALS, 2016, 6 (07)
[2]   Structural health monitoring of bolted joints using linear and nonlinear acoustic/ultrasound methods [J].
Amerini, F. ;
Meo, M. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2011, 10 (06) :659-672
[3]   Integrated impedance and guided wave based damage detection [J].
An, Yun-Kyu ;
Sohn, Hoon .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 28 :50-62
[4]  
Bickford J., 2008, Introduction to the design and behavior of bolted joints: non-gasketed joints, P1
[5]   Vision-based detection of loosened bolts using the Hough transform and support vector machines [J].
Cha, Young-Jin ;
You, Kisung ;
Choi, Wooram .
AUTOMATION IN CONSTRUCTION, 2016, 71 :181-188
[6]   Stress Level Measurement in Prestressed Steel Strands Using Acoustoelastic Effect [J].
Chaki, S. ;
Bourse, G. .
EXPERIMENTAL MECHANICS, 2009, 49 (05) :673-681
[7]  
Chalioris Constantin E., 2016, Case Studies in Construction Materials, V5, P1, DOI 10.1016/j.cscm.2016.03.003
[8]   Structural health monitoring of fatigue crack growth in plate structures with ultrasonic guided waves [J].
Cho, Hwanjeong ;
Lissenden, Cliff J. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2012, 11 (04) :393-404
[9]   MEASUREMENT OF ACOUSTOELASTIC AND 3RD-ORDER ELASTIC-CONSTANTS FOR RAIL STEEL [J].
EGLE, DM ;
BRAY, DE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 (03) :741-744
[10]  
Giurgiutiu V, 2008, STRUCTURAL HEALTH MONITORING: WITH PIEZOELECTRIC WAFER ACTIVE SENSORS, P1