Assessing cerebral arterial pulse wave velocity using 4D flow MRI

被引:20
|
作者
Bjornfot, Cecilia [1 ]
Garpebring, Anders [1 ]
Qvarlander, Sara [1 ]
Malm, Jan [2 ]
Eklund, Anders [1 ,3 ]
Wahlin, Anders [1 ,3 ]
机构
[1] Umea Univ, Dept Radiat Sci, SE-90187 Umea, Sweden
[2] Umea Univ, Dept Clin Sci, Neurosci, Umea, Sweden
[3] Umea Univ, Umea Ctr Funct Brain Imaging UFBI, Umea, Sweden
来源
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM | 2021年 / 41卷 / 10期
基金
瑞典研究理事会;
关键词
Atherosclerosis; arterial stiffness; arteriosclerosis; magnetic resonance imaging; neurovascular dysfunction; NEUROVASCULAR UNIT; COGNITIVE DECLINE; STIFFNESS; AGE; PRESSURE; 3D; QUANTIFICATION; DYSFUNCTION; DISEASE;
D O I
10.1177/0271678X211008744
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intracranial arterial stiffening is a potential early marker of emerging cerebrovascular dysfunction and could be mechanistically involved in disease processes detrimental to brain function via several pathways. A prominent consequence of arterial wall stiffening is the increased velocity at which the systolic pressure pulse wave propagates through the vasculature. Previous non-invasive measurements of the pulse wave propagation have been performed on the aorta or extracranial arteries with results linking increased pulse wave velocity to brain pathology. However, there is a lack of intracranial "target-organ" measurements. Here we present a 4D flow MRI method to estimate pulse wave velocity in the intracranial vascular tree. The method utilizes the full detectable branching structure of the cerebral vascular tree in an optimization framework that exploits small temporal shifts that exists between waveforms sampled at varying depths in the vasculature. The method is shown to be stable in an internal consistency test, and of sufficient sensitivity to robustly detect age-related increases in intracranial pulse wave velocity.
引用
收藏
页码:2769 / 2777
页数:9
相关论文
共 50 条
  • [21] Blood Flow Velocity Pulsatility and Arterial Diameter Pulsatility Measurements of the Intracranial Arteries Using 4D PC-MRI
    Kees M. van Hespen
    Hugo J. Kuijf
    Jeroen Hendrikse
    Peter R. Luijten
    Jaco J. M. Zwanenburg
    Neuroinformatics, 2022, 20 : 317 - 326
  • [22] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [23] Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI
    Rose, Michael J.
    Jarvis, Kelly
    Chowdhary, Varun
    Barker, Alex J.
    Allen, Bradley D.
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    Schnell, Susanne
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1673 - 1682
  • [24] Age-Related Reductions in Cerebrovascular Reactivity Using 4D Flow MRI
    Miller, Kathleen B.
    Howery, Anna J.
    Rivera-Rivera, Leonardo A.
    Johnson, Sterling C.
    Rowley, Howard A.
    Wieben, Oliver
    Barnes, Jill N.
    FRONTIERS IN AGING NEUROSCIENCE, 2019, 11
  • [25] Modeling Bias Error in 4D Flow MRI Velocity Measurements
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Brindise, Melissa C.
    Schnell, Susanne
    Markl, Michael
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (07) : 1802 - 1812
  • [26] A New Method for Cerebral Arterial Stiffness by Measuring Pulse Wave Velocity Using Transcranial Doppler
    Fu, Xian
    Huang, Chuming
    Wong, Ka Sing
    Chen, Xiangyan
    Gao, Qingchun
    JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2016, 23 (08) : 1004 - 1010
  • [27] 4D flow MRI hemodynamic biomarkers for cerebrovascular diseases
    Wahlin, Anders
    Eklund, Anders
    Malm, Jan
    JOURNAL OF INTERNAL MEDICINE, 2022, 291 (02) : 115 - 127
  • [28] Aortic Pulse Wave Analysis Is Not a Surrogate for Central Arterial Pulse Wave Velocity
    Gurovich, Alvaro N.
    Beck, Darren T.
    Braith, Randy W.
    EXPERIMENTAL BIOLOGY AND MEDICINE, 2009, 234 (11) : 1339 - 1344
  • [29] Cerebral Sinus Hemodynamics in Adults Revealed by 4D Flow MRI
    Dai, Chihang
    Zhao, Pengfei
    Ding, Heyu
    Lv, Han
    Qiu, Xiaoyu
    Tang, Ruowei
    Xu, Ning
    Huang, Yan
    Han, Xu
    Yang, Zhenghan
    Wang, Zhenchang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1706 - 1717
  • [30] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58