Rotating hinged total knee replacement: Use with caution

被引:126
作者
Pour, Aidin Eslam [1 ]
Parvizi, Javad [1 ]
Slenker, Nicholas [1 ]
Purtill, James J. [1 ]
Sharkey, Peter F. [1 ]
机构
[1] Rothman Inst, Philadelphia, PA 19107 USA
关键词
D O I
10.2106/JBJS.F.00893
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A rotating hinged total knee prosthesis may be utilized for the treatment of global instability or severe bone loss around the knee. Older generations of rotating hinged designs were associated with suboptimal outcomes. We evaluated the outcome of salvage knee reconstructions that had been performed with use of modern-generation modular segmental kinematic rotating hinged total knee prostheses. Methods: The cohort included forty-three patients (twenty-nine women and fourteen men) who underwent forty-four knee arthroplasties for the treatment of a non-neoplastic condition with use of a modern-generation kinematic rotating hinged prosthesis. Revision of a previous total knee arthroplasty in the presence of massive bone loss was the most common indication for surgery. Complete clinical and radiographic data were collected for all patients after a mean duration of follow-up of 4.2 years. Results: Reconstruction with a rotating hinged total knee prosthesis provided substantial improvement in function and reduction in pain. However, a relatively large number of complications and failures (including revision because of periprosthetic infection [three knees], aseptic loosening [four], and periprosthetic fracture [one]) were encountered, with a mean time to failure of 1.7 years. The rate of prosthetic survival was 79.6% at one year and 68.2% at five years with revision or reoperation as the end point. Conclusions: The present study highlights the commonly held opinion that a modular kinematic rotating hinged total knee prosthesis has a role for salvage reconstruction of the knee. In light of the relatively high rate of complications, we believe that this salvage procedure should be reserved primarily for elderly and sedentary patients. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:1735 / 1741
页数:7
相关论文
共 36 条
  • [1] Primary constrained condylar knee arthroplasty without stem extensions for the valgus knee
    Anderson, John A.
    Baldini, Andrea
    MacDonald, James H.
    Pellicci, Paul M.
    Sculco, Thomas P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (442) : 199 - 203
  • [2] BAIN AM, 1973, CLIN ORTHOP RELAT R, P65
  • [3] RESULTS WITH THE CONSTRAINED TOTAL KNEE PROSTHESIS IN TREATING SEVERELY DISABLED PATIENTS AND PATIENTS WITH FAILED TOTAL KNEE REPLACEMENTS
    BARGAR, WL
    CRACCHIOLO, A
    AMSTUTZ, HC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (04) : 504 - 512
  • [4] Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
  • [5] The use of a modular rotating hinge component in salvage revision total knee arthroplasty
    Barrack, RL
    Lyons, TR
    Ingraham, RQ
    Johnson, JC
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (07) : 858 - 866
  • [6] Barrack RL, 2002, ORTHOPEDICS, V25, P1020
  • [7] Is there a future for hinged prostheses in primary total knee arthroplasty?: A 20-year survivorship analysis of the Blauth prosthesis
    Böhm, P
    Holy, T
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 302 - 309
  • [8] Cameron HU, 1997, CAN J SURG, V40, P278
  • [9] Megaprostheses after resection of distal femoral tumors - A rotating hinge design in 30 patients followed for 2-7 years
    Choong, PFM
    Sim, FH
    Pritchard, DJ
    Rock, MG
    Chao, EYS
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (04): : 345 - 351
  • [10] LOOSENING OF FEMORAL COMPONENT IN SURFACE REPLACEMENT OF KNEE
    COLLEY, J
    CAMERON, HU
    FREEMAN, MAR
    SWANSON, SAV
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 92 (01) : 31 - 34