Tissue-equivalent proportional counters in a high-energy neutron field at CERN

被引:2
作者
Lim, T
BottollierDepois, JF
Festag, JG
Golnik, H
Grillmaier, RE
Hofert, M
Lindborg, L
机构
来源
NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE | 1997年 / 2867卷
关键词
D O I
10.1117/12.267920
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Within the framework of a research program of the Commission of European Communities (CEC) the reference radiation facility at CERN provided recently a mixed high-energy radiation field simulating the one found at civil aviation altitudes of about 10 km. In order to calibrate radiation detectors and to investigate their response to high-energy neutrons a series of measurements using five different instruments equipped with Low Pressure Tissue-Equivalent Proportional Counter (TEPC) and one Recombination Chamber (REM-2) has been carried out. The reference radiation field at CERN was produced by reactions of a primary beam mixed of 2/3 protons and 1/3 pions with a copper target and moderated by a concrete shielding. The paper summarises the results obtained with the five TEPC instruments and the REM-2, and discusses their characteristics.
引用
收藏
页码:300 / 305
页数:6
相关论文
共 50 条
[31]   Performance of a cylindrical tissue-equivalent proportional counter for use in neutron monitoring [J].
Chau, Q ;
Lahaye, T ;
Ménard, S ;
Donadille, L ;
Bolognese, T ;
Rannou, A .
RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) :297-300
[32]   Numerical modeling of the gas gain of low-pressure Tissue-Equivalent Proportional Counters [J].
Mazzucconi, D. ;
Bortot, D. ;
Pola, A. ;
Agosteo, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 983
[33]   HIGH-ENERGY LIMITATIONS IN NEUTRON SPECTROMETRY WITH PROTON-RECOIL PROPORTIONAL COUNTERS [J].
YULE, TJ .
TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01) :269-&
[34]   IMPROVING A MULTICELLULAR TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR PERSONAL NEUTRON DOSIMETRY [J].
BORDY, JM ;
BARTHE, J ;
LAHAYE, T ;
BOUTRUCHE, B ;
SEGUR, P .
RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) :175-178
[35]   A NEW CONCEPT OF A HIGH-SENSITIVITY TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR INDIVIDUAL NEUTRON DOSIMETRY [J].
BOUTRUCHE, B ;
BORDY, JM ;
BARTHE, J ;
SEGUR, P ;
PORTAL, G .
RADIATION PROTECTION DOSIMETRY, 1994, 52 (1-4) :335-338
[36]   Estimation of neutron quality factor using tissue equivalent proportional counters [J].
Borak, T.B. ;
Stinchcomb, T.G. .
Proceedings of the International Congress of Radiation Research, 1984, :1-04
[37]   NEUTRON DOSE AND QUALITY FACTOR DETERMINATIONS WITH TISSUE EQUIVALENT PROPORTIONAL COUNTERS [J].
BRACKENBUSH, LW ;
FAUST, LG .
HEALTH PHYSICS, 1973, 25 (03) :304-304
[38]   Microdosimetry studies at the BMRR and the MITR-II using miniature tissue-equivalent proportional counters [J].
Burmeister, J ;
Kota, C ;
Maughan, RL ;
Riley, K ;
Harling, O ;
Wielopolski, L ;
Ma, R ;
Coderre, J .
FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, :581-586
[39]   ON THE CALIBRATION OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS WITH BUILT-IN ALPHA-PARTICLE SOURCES [J].
SCHREWE, UJ ;
BREDE, HJ ;
PIHET, P ;
MENZEL, HG .
RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) :249-252
[40]   SPHERICAL TISSUE-EQUIVALENT PROPORTIONAL COUNTER WITH COAXIAL ELECTRIC-FIELD [J].
BELONOGII, PN ;
DROBCHENKO, EA ;
KHARLAMOV, AD .
MEASUREMENT TECHNIQUES, 1985, 28 (10) :901-903