Contrast-enhanced digital mammography and angiogenesis

被引:0
作者
Rosado-Mendez, I. [1 ]
Palma, B. A. [1 ]
Villasenor, Y. [2 ]
Benitez-Bribiesca, L. [3 ]
Brandan, M. E. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Fis, Mexico City 04510, Mexico
[2] INCan, Mexico City 04510, DF, Mexico
[3] UNAM Med Phys Program, Mexico City, DF, Mexico
来源
NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE | 2007年 / 958卷
关键词
cancer; mammography; digital mammography;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
Angiogenesis could be a means for pouring contrast media around tumors. In this work, optimization of radiological parameters for contrast-enhanced subtraction techniques in mammography has been performed. A modification of Lemacks' analytical formalism was implemented to model the X-ray absorption in the breast with contrast medium and detection by a digital image receptor. Preliminary results of signal-to-noise ratio analysis show the advantage of subtracting two images taken at different energies, one prior and one posterior to the injection of contrast medium. Preliminary experimental results using a custom-made phantom have shown good agreement with calculations. A proposal is presented for the clinical application of the optimized technique, which aims at finding correlations between angiogenesis indicators and dynamic variables of contrast medium uptake.
引用
收藏
页码:278 / +
页数:2
相关论文
共 9 条
[1]  
Dromain Clarisse, 2006, AJR Am J Roentgenol, V187, pW528, DOI 10.2214/AJR.05.1944
[2]   Contrast-enhanced digital mammography: Initial clinical experience [J].
Jong, RA ;
Yaffe, MJ ;
Skarpathiotakis, M ;
Shumak, RS ;
Danjoux, NM ;
Gunesekara, A ;
Plewes, DB .
RADIOLOGY, 2003, 228 (03) :842-850
[3]  
Kumar S, 1999, CANCER RES, V59, P856
[4]   A dual-energy subtraction technique for microcalcification imaging in digital mammography - A signal-to-noise analysis [J].
Lemacks, MR ;
Kappadath, SC ;
Shaw, CC ;
Liu, XM ;
Whitman, GJ .
MEDICAL PHYSICS, 2002, 29 (08) :1739-1751
[5]   Dual-energy contrast-enhanced digital subtraction mammography: Feasibility [J].
Lewin, JM ;
Isaacs, PK ;
Vance, V ;
Larke, FJ .
RADIOLOGY, 2003, 229 (01) :261-268
[6]  
Niklason LT, 1998, BREAST IMAGING, P151, DOI 10.3233/BD-1998-103-415
[7]   Development of contrast digital mammography [J].
Skarpathiotakis, M ;
Yaffe, MJ ;
Bloomquist, AK ;
Rico, D ;
Muller, S ;
Rick, A ;
Jeunehomme, F .
MEDICAL PHYSICS, 2002, 29 (10) :2419-2426
[8]   SPECTRAL DEPENDENCE OF GLANDULAR TISSUE DOSE IN SCREEN-FILM MAMMOGRAPHY [J].
WU, XZ ;
BARNES, GT ;
TUCKER, DM .
RADIOLOGY, 1991, 179 (01) :143-148
[9]   NORMALIZED AVERAGE GLANDULAR DOSE IN MOLYBDENUM TARGET RHODIUM FILTER AND RHODIUM TARGET RHODIUM FILTER MAMMOGRAPHY [J].
WU, XZ ;
GINGOLD, EL ;
BARNES, GT ;
TUCKER, DM .
RADIOLOGY, 1994, 193 (01) :83-89