Modernising tactile acuity assessment; clinimetrics of semi-automated tests and effects of age, sex and anthropometry on performance

被引:1
|
作者
Olthof, Nick A. [1 ,2 ,3 ,4 ]
Coppieters, Michel W. [3 ,4 ,5 ]
Moseley, G. Lorimer [6 ]
Sterling, Michele [7 ,8 ]
Chippindall, Dylan J. [3 ,4 ]
Harvie, Daniel S. [1 ,2 ,3 ,4 ,6 ]
机构
[1] Griffith Univ, Sch Hlth Sci & Social Work, Brisbane, Qld, Australia
[2] Griffith Univ, Sch Hlth Sci & Social Work, Gold Coast, Qld, Australia
[3] Griffith Univ, Menzies Hlth Inst Queensland, Brisbane, Qld, Australia
[4] Griffith Univ, Menzies Hlth Inst Queensland, Gold Coast, Qld, Australia
[5] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Amsterdam Movement Sci, Amsterdam, Netherlands
[6] Univ South Australia, IIMPACT Hlth, Adelaide, SA, Australia
[7] Univ Queensland, RECOVER Injury Res Ctr, Brisbane, Qld, Australia
[8] Univ Queensland, NHMRC Ctr Res Excellence Rd Traff Injury Recovery, Brisbane, Qld, Australia
来源
PEERJ | 2021年 / 9卷
基金
英国医学研究理事会;
关键词
Neurologic examination; Touch perception; Tactile acuity; Locognosia; Reliability; Neck; Chronic pain; LOW-BACK-PAIN; 2-POINT DISCRIMINATION; SPATIAL ACUITY; RELIABILITY; BODY; NECK; PEOPLE; HAND; REGIONS; RESPONSIVENESS;
D O I
10.7717/peerj.12192
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background. Reduced tactile acuity has been observed in several chronic pain conditions and has been proposed as a clinical indicator of somatosensory impairments related to the condition. As some interventions targeting these impairments have resulted in pain reduction, assessing tactile acuity may have significant clinical potential. While two-point discrimination threshold (TPDT) is a popular method of assessing tactile acuity, large measurement error has been observed (impeding responsiveness) and its validity has been questioned. The recently developed semi-automated 'imprint Tactile Acuity Device' (iTAD) may improve tactile acuity assessment, but clinimetric properties of its scores (accuracy score, response time and rate correct score) need further examination. Aims. Experiment 1: To determine inter-rater reliability and measurement error of TPDT and iTAD assessments. Experiment 2: To determine internal consistencies and floor or ceiling effects of iTAD scores, and investigate effects of age, sex, and anthropometry on performance. Methods. Experiment 1: To assess inter-rater reliability (ICC(2,1)) and measurement error (coefficient of variation (CoV)), three assessors each performed TPDT and iTAD assessments at the neck in forty healthy participants. Experiment 2: To assess internal consistency (ICC(2,k)) and floor or ceiling effects (skewness z-scores), one hundred healthy participants performed the iTAD's localisation and orientation tests. Balanced for sex, participants were equally divided over five age brackets (18-30, 31-40, 41-50, 51-60 and 61-70). Age, sex, body mass index (BMI) and neck surface area were assessed to examine their direct (using multiple linear regression analysis) and indirect (using sequential mediation analysis) relationship with iTAD scores. Results. Mean ICC(2,1) was moderate for TPDT (0.70) and moderate-to-good for the various iTAD scores (0.65-0.86). The CoV was 25.3% for TPDT and ranged from 6.1% to 16.5% for iTAD scores. Internal consistency was high for both iTAD accuracy scores (ICC(2,6) = 0.84; ICC(2,4) = 0.86). No overt floor or ceiling effects were detected (all skewness z-scores < 3.29). Accuracy scores were only directly related to age (decreasing with increasing age) and sex (higher for men). Discussion. Although reliability was similar, iTAD scores demonstrated less measurement error than TPDT indicating a potential for better responsiveness to treatment effects. Further, unlike previously reported for TPDT, iTAD scores appeared independent of anthropometry, which simplifies interpretation. Additionally, the iTAD assesses multiple aspects of tactile processing which may provide a more comprehensive evaluation of tactile acuity. Taken together, the iTAD shows promise in measuring tactile acuity, but patient studies are needed to verify clinical relevance.
引用
收藏
页数:23
相关论文
共 2 条
  • [1] Longitudinal Assessment of Hippocampal Atrophy in Midlife and Early Old Age: Contrasting Manual Tracing and Semi-automated Segmentation (FreeSurfer)
    Fraser, Mark A.
    Shaw, Marnie E.
    Anstey, Kaarin J.
    Cherbuin, Nicolas
    BRAIN TOPOGRAPHY, 2018, 31 (06) : 949 - 962
  • [2] Effects of socio-demographic variables on performance on the Cambridge neuropsychological automated tests for the assessment of dementia and Portuguese norms for older adults living in retirement homes
    Goncalves, Marta Matos
    Pinho, Maria Salome
    Simoes, Mario Rodrigues
    CLINICAL NEUROPSYCHOLOGIST, 2016, 30 : 1395 - 1428